IPDB › China Industry › Instruments & Meters
China, Chinese Mains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke Detector1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Fire ControlFire Alarm Smoke Detector220V Smoke DetectorDual Power Smoke Alarm
Zhejiang Jiaboer Electronic Technology Co., Ltd.
Preview:
Product Description AC 220V main power DC 9V backup battery with wired interconnection photoelectric smoke alarm(wireless module optional) Technical Specifications:Power SourceAC 220V-AC240V, DC 9Vbattery backupAlarm Volume>85dB(A) @ 3 metersAC Quiescent Current< 100mALow Voltage Threshold≤7.5VAC Alarm Current< 100mAHush Time8minutesDC Quiescent Current< 10uAProduct Service Life>10 yearsDC Alarm Current< 28mAHumidity Range< 93% relative humidity (RH)Alarm Sensitivity0.10-0.16dB/mTemperature Range0oC to 40oCComply With StandardEN14604:2005/AC:2008Size140mm in diameter x 44.9mm depthSound Pattern (BI 0.5s - pause 0.5s - BI 0.5s - pause 0.5s - BI 0.5s - pause 1.5s, with the RED LED flash, repeat this alarm pattern)Details of the product function:Standby modeafter the product is installed, if the smoke alarm device operate properly, the red LED flashes once every 40 secondsLocal alarming modewhen the smoke alarm device detect particles of combustion and the concentration of smoke reaches the alarm threshold, the red LED will flash once per second with pulsating alarm until the smoke is disappearedInterconnection alarming modewhen the smoke alarm device detect particles of combustion and the concentration of smoke reaches the alarm threshold, the alarm will send local alarm signal, other interconnection alarms will send alarm signals. The wired interconnection alarms will go into interconnection alarm mode: BI - BI - pause 1.2s, with the red LED flashes, this alarm pattern is repeatedLow battery modewhen the battery voltage below threshold, the red LED will flash once every 40 seconds with a sound of "chrip"Fault modeif the alarm detection signal decays below threshold, the alarm chirp occurs without LED flashes every 40 secondsSilence modepress the test button at least 2 seconds, it will go into silence mode for approx 8 minutes. That will desensitize the alarm sensitivity temporarily. At this time, the red LED will flash once every 8 secondsNo disturb modewhen the alarm device is in low battery mode, in order to avoid disturbing you at night, please press the test button for 3 seconds which will mute this warning tone for about 14 hours. After 14 hours, the warning tone will still go off. The red LED will flash once every 40 seconds during No disturb modeTest modetest the unit to ensure proper operation by pressing the test button. At this time, the red LED will flash once per second with pulsating alarm until test button is releasedNOTEWEEKLY TESTINGIS REQUIRED.Wireless Interconnection Set up:>1<Select one of smoke alarms as the MASTER unit. Treat other units as SLAVE units.>2<Press the test button on the MASTER unit three times within two seconds, the red LED will flash quickly, the unit is now in sending radio signal mode. This mode will last for 48 seconds.>3<While the MASTER unit is in sending radio signal mode, press the test button on any SLAVE unit three times within two seconds, the SLAVE unit learns this signal and completes the pairing after a sound "beep" with light flash once>4<Repeat the above steps on all other SLAVE unitsClear wireless connection functionPress the test button on any SLAVE unit three times within two seconds, the red LED will flash quickly, then press and hold the test button again until the red light goes out the first time and release the button immediately, the red LED will flash slowly, at this time, press the test button again, the SLAVE unit will beep 3 times, which means that the SLAVE unit clears wireless connected successfully.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...