IPDB › China Industry › Instruments & Meters
China, Chinese 6000A Clamp on CT Class a Handheld Three Phase Power Quality Analyzer1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Electronic InstrumentFrequency MeterThree Phase Power Quality AnalyzerPower Analyzer
Beijing GFUVE Electronics Co., Ltd.
Preview:
Product Description Product Description GFUVE GF438II 6000A Clamp on ct Class A Handheld Three Phase Power Quality AnalyzerGF438II handheld three phase power quality analyzer offer the best ability in power quality analysis, GF438II handheld power quality analyzer help locate, predict, prevent and troubleshoot power quality problems in three phase and single phase power distribution systems. Additionally, GFUVE patented energy loss algorithm, unified power measurement, measuring and counting energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy losses in the system. FeaturesTroubleshoot real-time: Analyze the trends using the cursors and zoom tools-even while background recording continues.Automatic Transient Mode: Capture 200 kHz waveform data on all phases simultaneously up to 6 kVMeasure all three phases and neutral: With included four current probesSystem-Monitor: Up to ten power quality parameters on one screen according to EN50160 power quality standardView graphs and generate reports: With included analysis softwareLogger function: Configure for any test condition with memory for over 400 parameters at user defined intervals.Mains signaling: Measure interference from ripple control signals at specific frequenciesInrush mode: For troubleshooting nuisance circuit breaker tripping.AutoTrend: Every measurement you see is always automatically recorded, without any setup.Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard.Battery Life: Seven hours operating time per charge on NiMH battery packHigh safety rating: 600 V CAT IV/1000 V CAT III rated for use at the service entranceComparing to online power quality analyzer, E6000 handheld type with small size, light weight, easy for the engineer to carry and carry out to survey work whenever and wherever. Easy to wiring It can operate directly to the line under test under the circumstances that the Power Grid without interrupt. Multi-range current switching based on actual demand, the different range of current clamp can be replaced to improve measurement accuracy. ApplicationsFrontline troubleshooting - quickly diagnose problems on-screen to get your operation back onlinePredictive maintenance - detect and prevent power quality issues before they cause downtimeQuality of service compliance - validate incoming power quality at the service entranceLong-term analysis - uncover hard-to-find or intermittent issuesLoad studies - verify electrical system capacity before adding loadsEnergy assessments - quantify energy consumption before and after improvements to justify energy saving devices.Product Parameters NameMeasurement typeVoltagerms, ava, pk+, pk-, rms-1/2, CFFrequencyFreqCurrentrms, ava, pk+, pk-, rms-1/2, CFPower & energyP, S, Q, PF, DPF, WComputationTHD, DC, 1-63 Harm, 1-62 InHarm, 1-35 HiHarm, 1-62 SubHarmVoltage harmonicTHD, DC, 1-63 Harm, 0-62 InHarm, 1-35 HiHarm, 1-62 SubHarm , KFCurrent harmonicTHD, DC, 1-62 HarmHarmonic powerIa, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutesFluctuation and flickeringPST, PLT, Fluct, Fluct MaxUnbalV Pos, A pos , V neg , A neg , V zero, A zero, UnbalEvent logVoltage swell, voltage sags, DIP, surge current, voltage and currentdistortion out of limit, odd harmonics containing rate out oflimited, unbalanced voltage current out of limit, frequency out of limit, PST out of limit, PLT out of limit, long-term voltage interruption, voltage fluctuation deviation, voltage harmonics out of limit, 2-25st harmonicsout of limitP, Q, S nameMeasurement typeMeasurement typesP: Calculate by every 10 cyclesS: Calculated by the effective value of voltage and currentQ: Calculated by the apparent power, active powerDisplayTable charts, trend chartMeasuring rangeAccording to the range of the voltage and currentResolution0.001WAccuracy±0.5%UrmsMeasurement typeMode'Calculated by the square root value of 10/12 cycleMeasuring circuit1P2W/ 2P3W /3P3W/ 3P4WBasic frequency of the measuring circuit50Hz, 60HzInput channels4 phase voltage, 4 phase currentDisplay modeEffective current value of each channelRange120V, 230V, 400V, 1000V, Max 1000V instantaneous voltageResolution0.001VAccuracy0.1% RGArmsMeasurement typeMode'Calculated by the square root value of 10/12 cycleDisplay modeEffective current value of each channelRangeCurrent: according to the current clampsOption Current clamps:5A/50A/100A/500A/1000AFlexible Current probe: 1000A/3000A/6000AResolution0.001AAccuracy0.1% + accuracy of the current clampsFrequencyMeasurement typeMeasurement modeCalculate by 10 cycles (50Hz) or (60Hz)Display modeMeasurement by 10 cyclesNominal frequency/resolution50.000Hz/0.001Hz or 60.000Hz/0.001HzBandwidth measurement42.5-57.5Hz or 52.5-67.5HzAccuracy±0.001HzHalf-wave RMS current/voltageMeasurement typeMeasurement modeCalculate by every 2 cycles. Each cycle ,1/2 cycle made up of a waveform calculationMeasuring range/resolutionVoltage: 120V/0.01V, 230V/0.01V, 400V/0.01V, 1000V/0.01V, Current: According to the current clampsmeasurement accuracy±0.1%Power factorMeasurement typeMeasurement modeThe ratio of average power to apparent powerDisplay modeReal-time data showedMeasurement range/resolution-1.000-1.000/0.001Accuracy±0.1%Vfund, Afund, Harmonic powerMeasurement typeMeasurement modeMeet IEC61000-4-7,Analysis time window is ten cyclesWindow points5120 pointsDisplay modeForm figure, trend charts, histogramsNumber of measurement1-50 TimesMeasurement accuracyVfund >1%: Error<1% Vfund <1%: Error<0.05% Rated VoltageAfund >3%: Error<1% Afund <3%: Error<0.05% Current rangeInHarm Voltage, InHarm currentMeasurement typeMeasurement modeMeet IEC61000-4-7, Analysis time window is ten cyclesWindow points5120 pointsDisplay modeForm figure, trend charts, histogramsNumbers of measurement1-16 groupsMeasurement accuracyVfund >1%: Error<1% Vfund <1%: Error<0.05% Rated VoltageAfund >3%: Error<1% Afund <3%: Error<0.05% Current rangeHiHarm Voltage, HiHarm currentMeasurement typeMeasurement modeMeet IEC61000-4-7, Analysis time window is ten cyclesWindow points5120 points every 10 cyclesDisplay modeForm figure, trend charts, histogramsNumbers of measurement1-35 groups/2100Hz-8900HzMeasurement accuracyVfund >1%: Error<1% Vfund <1%: Error<0.05% Rated VoltageAfund >3%: Error<1%Afund <3%: Error<0.05% Current rangeVoltage/current Unbal (pos, neg)Measurement typeMeasurement mode3P3W or 3P4W, using three phase of fundamental wave components to calculateDisplay modeForm figure, trend charts, histogramsMeasurement accuracyVoltage unbal: ±0.2% Current unbal: ±0.5%Voltage fluctuationMeasurement typeMeasurement modeCalculate by the quadratic mean of half waveDisplay modeForm figure, trend chartsMeasurement accuracy±1%IEC FlickeringMeasurement typeMeasurementP short term (Pst) , P long term (Plt)Measurement modeAccording to IEC61000-4-15 Standard to calculate Pst (10 mins) Plt(2 hours)Display modeForm figure, trend chartsMeasurement range0-20Measurement accuracy±5%Surge currentMeasurement typeMeasurement modeHalf-wave RMS of current is higher than set value and sustaintime is 10ms-1minDisplay modeMaximum of the surge current and surge current waveMeasurement accuracy0.1%Voltage swell, Voltage sags, DIPMeasurement typeMeasurement modeSwell: When half-wave RMS of voltage is higher than set valueand sustain time is 10ms-1min, judged as swell.Sags: When half-wave RMS of voltage is lower than set value andsustain time is 10ms-1min, judged as sags.DIP: half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as DIPDisplay modeSwell, sags, DIP wave sustain time, extent and so on.Measurement accuracy0.1%MachinerySize263mm x 168mm x 65mmKey21PCSBinarybinary input:1 ; binary output:1Comunication PortUSB, 10/100M portWeight2KGPower supplyVoltage input110V-240VAdapter outpu15V, 3ABatteryRechargeable nickel metal hydride, 5500mAhBattery working time≥ 6hBattery recharging time5h (Environment temperature 25°C)Power saving facilityLCD backlight brightness is adjustable, standby time is adjustableDisplaySize112.8 x 84.6mmColor260000 colorResolutions640 x 480BrightnessMax 350 cd/m2 (Typ), brightness is adjustableContrast500:1 (Typ)Visual angle70/70/50/70 (Typ.)(CR ≥10) ( Left/ Right/ UP/Down)EnvironmentWorking environment0°C to +45°C, humidity below 90rh%Storing environment'-20°C to +50°C, humidity below 95rh% (non-condensing)StoreTypeTF card (inbuilt)Size32GStandardsMeasurement methodIEC 61000-4-30Measurement performanceIEC 61000-4-30 A LVLFlickeringIEC 61000-4-15HarmonicIEC 61000-4-7SafetyStandardGB 4793.1-2007/IEC 61010-1:2001: "Measurement, control and laboratory electrical equipment safety requirements", first part:general requirements. Security level: CAT III 1000 V/ CAT IV 600 V./td>MAX voltage of phase angle inputCAT III 1000V/CAT IV 600V Detailed Photos
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...