IPDB › China Industry › Instruments & Meters
China, Chinese Manufacturer 8/16/32kv Arc Multipulse Low Medium Voltage Detector Cable Fault Locator1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Test InstrumentCable TesterCable Fault LocatorUnderground Cable Fault Locator
Xian XZH Electric Power Technology Co., Ltd.
Preview:
Product Description Product DescriptionPortable low medium and high voltage cable fault locating systemCable fault pre-location: with the reflectometer XHGG502 based on the low-voltage impulse reflection method(TDR), and high-voltage decay(ICE) method (DECAY)and(ARC)method.XHDD503C uses acoustic-magnetic synchronization method, equipped with 2048 J surge generator and intelligent digital signal receiver.Cable pipe locator: XHLJ507C is an multifunctional equipment, with this equipment, you can realize of cable path tracing, buried depth detection, cable fault point precise location.High voltage 2048 J surge generator XHHV535-4TS is accompanied by a surge levels switch which allows to achieve the maximum surge impulse energy at 8, 16 and 32 kV. It has features operator safety assurance systems and provides a reliable and comprehensive technical solution for low- and medium-voltage cables faults. XHGG502Cable fault pre locatorXHDD503CCable fault pinpointerXHGX507CCable path comprehensive testerXHHV535-4TSHigh voltage surge generator Technical specification XHGG502 Main features? The reflected signal sent by the pulse coupler is automatically displayed, and the full-length waveform of the cable open circuit is displayed at the same time.? Automatic calculation and display of fault distance;? It has the function of storing massive test waveforms: the waveforms obtained from the field test can be conveniently stored in the instrument according to the specified order, and can be recalled and observed at any time;? With standard printer USB interface;? Simple operation and high reliability. Has a very high cost performance;? Built-in polymer lithium battery power supply, which can test cable open circuit and low resistance short circuit fault in no power supply environment.The test working modes of XHGG502 ARC cable fault pre locator include low voltage pulse method, high voltage flashover method, and multiple pulse method. Here focus on the multiple pulse method that is different from other devices.The below picture shows low voltage pulse test mode of XHGG502, test cable length, cable open circuit fault distance, short circuit fault distance.The below picture shows high voltage flashover test mode of XHGG502, measured cable fault distance. Sampling frequency400MHzMinimum resolution0.5m (100m/us)Low voltage pulse width0.2uS/2uS/4uSTest blind zone≤20mRanging range≥68kmMeasurement error≤±(0.5%×L+1m), L is the cable lengthThere are three test cable lengths<1km (short distance); <3km (medium distance); >3km (long distance), (low-voltage pulse test amplitude: 400Vpp)Pulse coupler withstand voltageDC 35kVMeasuring pulseLow voltage pulse 300V±10%Output impedance350 OhmInput signal gain±64dBPower consumption120VApropagation speed factor10-300m/μsWorking conditionstemperature -25oC~+65oC, relative humidity 85%, atmospheric pressure 750±30mmHgVolume and weightCable fault tester 430×380×220mm-10kg;Pulse coupler 430×380×220mm-10kgXHDD503CThe cable fault location instrument uses the acoustic and magnetic synchronization method to determine the power cable fault point. The electronic flashover is generated by the impact discharge generator, picked up and amplified by the corresponding probe, and the precise location of the fault point is determined by auditory and visual judgment. It is a device that completes the precise positioning of the cable fault point within the rough measurement range and collects the acoustic and magnetic time difference. It integrates positioning technology, path-assisted testing and other technologies, providing multiple test modes and rich and diverse prompt information to efficiently and accurately complete cable fault location.This cable fault pinpointer is suitable for low-resistance, short-circuit, open-circuit and disconnection faults of power cables, high-frequency coaxial cables, street light cables, and buried wires made of various materials with different cross-sections and media, as well as high-resistance leakage and high-resistance flashover. Fault. The technical parameters comply with "GB/T 18268.1 Anti-interference requirements for test equipment used in industrial sites". 1Filter parametersAll-pass: 100Hz~1600Hz.Low pass: 100Hz~300Hz.Qualcomm: 160Hz~1600Hz.Bandpass: 200Hz~600Hz.2Channel gain8 levels adjustable.3Magnetic channel gain8 levels adjustable.4Output gain16 levels (0~112db)5Output impedance350Ω6Acoustomagnetic positioning accuracy less than 0.2m.7Path identification accuracy less than 0.5m.8Power supply4*18650 standard lithium batteries.9Standby timemore than 8 hours.10Volume428L×350W×230H11Screen pixels854-48012Brightness800nit13Transmission speed unit0-100ms14Accuracy1ms15Sound bandwidth100-1.6khz16Magnetic coil bandwidth100-20kHZ17Both sound and magnetism aregreater than 75db18Weight 6.5kg.19Ambient temperature-25~65oC; Relative humidity: ≤90%. XHGX507CXHGX507C is a path detection instrument with strong comprehensive performance.It has multiple functions such as pipeline path detection, cable identification, fault finding, etc. The instrument consists of a transmitter, a transmitting current clamp,a receiver, a receiving flexible current clamp, a connecting test line, and an A-frame (optional).The cable path tester can be used for path detection, pipeline census and depth measurement of metal pipelines and underground cables without excavation. The instrument uses a variety of filtering technologies, has anti-interference capabilities, can accurately locate and measure depth, and is suitable for the detection and patrol of various underground metal pipelines, pipeline management and maintenance, municipal planning and construction, and pipeline detection in power supply and other departments. It is one of the necessary instruments for pipeline maintenance units. This function is achieved by the cooperation of signal transmitters, receivers, signal transmitting clamps and connecting test lines.Features1. Multiple detection modes: classic positioning mode, wire cruise mode, signal distortion measurement mode;2. Classic positioning mode: compass, direction and signal amplitude display, intuitive display of the left and right directions of the pipeline.3. Wire cruise mode: 360° all-round pipeline path indication, continuous display of depth, current and relative position of pipeline.The interface is simple and intuitive, and can be operated without experience4. Signal distortion measurement mode: simultaneous display of peak and trough waveforms. In the distortion-free site, the peak and trough positions should be consistent, and the site shape should be symmetrical relative to the center line.5. Current direction determination (partial frequency), can eliminate interference from adjacent lines and prevent tracking errors by calibrating the current direction.6. Fully digital high-precision sampling and processing: stable and reliable, ultra-high sensitivity, extremely narrow receiving passband, strong anti-interference ability, and can fully suppress the power frequency and harmonic interference of adjacent running cables and pipelines.7. Multiple detection frequencies: 11 active detection frequencies and 3 passive detection frequencies. 8. The transmitter has multiple signal output modes: direct output, caliper coupling, and induction method.9. The transmitter has digital amplified power output, fully automatic impedance matching, and fully automatic protection.XHHV535-4TS The XHHV535-4TS high voltage pulse generator can be used impulse discharge and withstand voltage test in low and high voltage cable fault test. High-precision test cable fault sampling waveform module and small transformer are installed inside, which can truly achieve the effect of not being damaged by impact, and it also has the functions of automatic timing impact, manual impact and withstand voltage test.High voltage surge generator XHHV535-4TSSurge voltage levels and adjustmentrangesLevel 1 : 0-8KVLevel 2: 0-16KVLevel 3: 0-32KVSurge voltage levels switchManualVoltage adjustment typeContinuousIndicationHigh-voltage side voltage metering, indication of output voltage and current in real timeSurge energy at each levelUp to 2048JOperating modeSingle trigger, cycle, DCOperating modes switchManualImpact timeabout 7 seconds for automatic impact, arbitrary control time for manual impactImpact power2KVAContinuous output current60mABuilt-in capacitor4μF/32kV, 16μF/16kV, 64μF/8kV three-speed adjustmentSafe operationWith zero start protection function, safe and reliableDischargeUnique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the deviceWorking powerAC 220V±10% 50Hz±2Hz (other voltage and frequency can be customized)DC withstand voltage testingOutput voltage adjustment andindication range 0-32KV, Output current indication range 0-20ABurn currentFault conditioning (burning) with current up to60 mA @ 32 kV, 120 mA @ 16kV, 240mA@8kV.Connecting cableHigh voltage output cable: 5m, Protective earthing cable:5m,power cord 2.5m. Cables can be customized according to customer requirements.SafetyOver-voltage, Over-current, Overheating protection.Automatic discharge after operation.Protection ratingNot lower than IP54Working powerAC 220V±15%, 50Hz±2HzDimensions(mm)534L×444W×805HTotal weightAbout 120kg If you want to know more product-related information, please contact me, I will be honored to answer your questions.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...