IPDB › China Industry › Instruments & Meters
China, Chinese Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
TransmitterWeight Transmitter20mA Output Load Cell AmplifierOutput Load Cell Amplifier
Shenzhen Sensor and Control Company Limited
Preview:
Product Description Weight transmitter 0-5v 0-10v 4-20mA output load cell amplifier Product List Sensorcon Product ListsStrain GaugeLoad CellTorque SensorDisplayLinear Strain gauge-AAWireless sensorSlip ring rotary torque sensorPlatform scale displayHalf bridge strain gauge-BB,HA,GB,FBMicro load cellContactless rotary torque sensorTruck scale displayShear/torque strain gauge-AB,HASingle point load cellStatic torque sensorControllerFull bridge strain gauge-EB, FG,FDButton load cellMetersJunction box Tee Rosettes strain gauge-CA,BAShear beam load cellCouplingBig screen displayRound type strain gaugeS type load cell AmplifierSemi-conductor strain gaugeColumn load cell Bridge type load cell Product Overviews Size: Features: Plastic housing, durable, cost-effectiveHousing and wire joints are waterproof design, good sealingHigh precision amplifier circuit, good stabilityAnti-jamming performanceWide sensitivity input rangepower supply with reverse protection, surge protection, overcurrent protectionSensor excitation voltage adjustablePortable, small size, light weight, easy to installSuitable for weighing, pull push force, torque, tension and other strain sensor Parameter Mode PY-V-SP Input Signal mV Sensitivity range Standard: 1MV/V, 1.5MV/V, 2MV/V, 3MV/VOptional: 0.5MV/V, 4MV/V, 5MV/V ,6MV/V Load cell Excitation Voltage 5~15VDC(Adjustable) Operating Temperature -20~60 Operating Humidity <90%RH Protection grade IP65 Installation Housing fixing Housing material ABS Working Excitation voltage Standard: 12VDC, Optional: 24VDC Output signal Current:4~20mA, 0~10mA, 0~20mA Voltage:0~5V, 0~10V, 1~5V, ±5V, ±10V Please notify us which output you want when place orderCustomized output for voltage output is supported Accuracy Current output type ≥ 0.05%F.S Voltage output type ≥ 0.1%F.S Load cell connection At most 4 units of load cell in 350 ohm Connection: Wire definition INPUT E+ S+ S- GND GNDD Load cell Input Load cell Exc + Load cell Signal+ Load cell Signal- Load cell Exc - Shield OUTPUT 24V Out GND GNDD Transmitter output Transmitter Exc+ Transmitter Signal output Transmitter Exc-(0V) Shield VR Zero Span Sensor bridge voltage adjustment potentiometer ZERO C potentiometer Full-scale control point potentiometer I Zero-Current type, V Zero-Voltage type I Span-Current type, V Span-Voltage type Calibration: 1. Excitation voltage regulation1.1 Transmitter 24V power supply, a) When output signal is 0-10mA, 0-20mA, 4-20mA, 0-5V, 1-5V and ± 5V,Excitation voltage is adjusted to 8-10.5V, (load ≤ 500Ω), factory default setting is 10.1V, b) When output signal is 0-10V, excitation voltage is adjusted to 11-12VDC, (load ≤ 500Ω), factory default setting is 11V; 1.2 Transmitter 12V power supply When output signal is 0-10mA, 0-20mA, 4-20mA, 0-5V, 1-5V and ± 5V, the excitation voltage is adjusted to 6-8.5V, (load ≤ 320Ω), factory default setting is 8.01V 1.3 User can adjust the "VR" according to actual situation. Adjust excitation voltage according to the sensor impedance but should not be higher than the max. Excitation voltage of load cell otherwise it will cause damage to the sensor or the sensor will not work properly. 2. Zero adjustmentFirst leave the system under no-load state, adjust the "ZERO" potentiometer to adjust the zero deviation. Till the indication is to zero. 3. Gain adjustmentAdd certain weight to the system, (recommend 60% to 100% full scale), Calculate output value based on the ratio of added weight and the max. measuring value. Adjust the "SPAN" potentiometer till the indicator is to Load ratio indication 4. Re-examinationleave the system under no-load state, measure zero output; add certain weight, measure the output again and see whether it is in line with the expected gain. If not, please repeat steps 2, 3 Note: After the adjustment is done, fix the end of the potentiometer with a sealant or glue to prevent any changing of potentiometer's resistance from vibration Terms and Conditions1, in strict accordance with the definition of wiring, with particular attention to distinguish between the sensor and the output side, the wrong wiring may cause no output or damage.2, Except the potentiometer, all other electronic components should not have any change. 3, the device should be installed to the place without vibration impact, the installation should be reliable, beware of bumps and no strong corrosive gas around Load cell Accessorie Company InformationSensor and Control Co., Ltd. was founded in 2006, mainly engaged in Torque Sensor, Load Cell, Pressure Transducer, Strain Gauges and Weighing Indicators. Since establishment, we insist the guidelines of "Customer Oriented, Quality Focused, Professional Service "All products we supply are environment friendly and has passed RoHS test. Sensorcon, in accordance with the principle of the introduction of advanced professional ultrasonic gas cleaning, clean Room patches, automatic temperature compensation and detection, high and low temperature testing and thermal experiments, laser welding and printing, CAD design, manufacturing and testing sensor test equipment and production technology ,manufacture all varieties of sensors, high precision, stable performance and also has antiseptic, waterproof, anti-explosion, anti-lightning, etc favored deeply by users. Packaging & Shipping
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...