IPDB › China Industry › Instruments & Meters
China, Chinese Multifunction Portable Single Phase Kwh Meter Testing Set with Power Source1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Meter for ElectricityOther Meters for ElectricityMultifunction Reference Standard MeterReference Standard
Beijing GFUVE Electronics Co., Ltd.
Preview:
Product Description GF102 Portable Single Phase Kwh Meter Testing Set with Power SourceDetailed PhotosProduct Description GF102 single phase energy meter testing set used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology. High voltage and current output. Widely used in lab and field.FeaturesMeter under testing: 1P2WTesting mode: Active power, reactive powerTest 3PCS or 2PCS meter synchronouslyStarting test and creeping testReference standard and power source integrated, easy to carry.Measuring mechanical meter and electric meterOperating by manual keyboard or PCWith shortcut key of normal test point, speed up testingInternal large capacity storage device for mass memoryLocal checking the testing resultOverload, short circuit, open circuit protectionWith self-checking functionTechnical DataVoltageTest voltage output (Phase-Neutral)0V~264VPower of the voltage outputMax. 30VA, 15VAResolution0.01%Accuracy0.1%, 0.2%Stability0.02%/120s, 0.05%/120sDistortion factor< 0.3% for linear resistance loadCurrentTest current output1mA~120A, 1mA~60APower of the current outputMax. 100VA, 30VAResolution0.01%Accuracy0.1%, 0.2%Stability0.02%/120sDistortion factor< 0.3% for linear resistance loadPhase angleRange0 -- 360°Resolution0.1°Accuracy0.2°FrequencyRange45Hz~65HzResolution0.005HzPulse outputHigh frequency output(CH)1.666× 105 HzLow frequency output(CL)5× 10-5× CHPulse inputInput channel3Input frequencyMax. 20HzOtherVoltage Supply220V± 10% 50/60Hz± 2HzAmbient temperature-10° C -- +40° CRelative humidity35% -- 85%Accuracy class0.02%, 0.05%, 0.1%Power SupplyOne Phase AC 100-265V, frequency 50/60Hz.AC Voltage OutputRange57.7V, 100V, 220V, 380V; max 600VAdjustment range(0-120)%RG(1)Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.Stability0.01%/120sDistortion0.1% (Non-capacitive load)Output load25VA or 50VAMeasuring accuracy0.02%RG or 0.05%RGAC Current OutputRange200mA, 1A, 5A, 20A, 100A; max 120AAdjustment range(0-120)%RGAdjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.Stability<0.01%/120sDistortion≤0.1% (Non-capacitive load)Output load50VA or 100VAAccuracy0.02%RG or 0.05%RGPower OutputActive power output stability<0.01%RG/120sReactive power output stability<0.02%RG/120sActive power measuring accuracy0.02%RG or 0.05%RGReactive power measuring accuracy0.05%RG or 0.1%RGPhase OutputOutput adjustment range0°-359.999°Output adjustment fineness10, 1, 0.1, 0.01 as optional.Resolution0.01°Accuracy0.02°Power FactorAdjustment range-1 ~ 0 ~ 1Resolution0.0001Measurement accuracy0.0005Frequency OutputAdjustment range40Hz-70HzOutput adjustment fineness5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.Resolution0.001HzAccuracy0.002HzVoltage /Current/Harmonic SettingHarmonic number2-63timesHarmonic content0-40%Harmonic phase0-359.99Harmonic setting accuracy(10%±0.1%)RD(2)Power Energy Measurement ErrorActive power energy0.02%RG or 0.05%RGReactive power energy0.05%RG or 0.1%RGPower Pulse OutputPower pulse typeactive pulse, reactive pulseActive power pulse output5V, 10mAPower Pulse InputEnergy pulse typesupport active and reactive pulse, the highest frequency power pulse input is 200K.StandardStandardIEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002;JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019;DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016SafetyIsolation protectionIEC 61010-1:2001Measurement Category300 V CAT III, 600 V CAT IIDegree of protectionIP20Declaration of conformityCE & CNAS certifiedFunctionsLCD7 inch touch TFT color LCDCommunication portRS232 or USBProgrammableYesMeter position1pc or 3pcsPC control softwareOptionalMechanical parametersDimensions (W×D×H) (mm)455x440x150Weight (kg)12Environmental conditionsAmbient temperature-10°C to +40°CRelative humidity35%-85%(1) RG means range, the same as below;(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...