IPDB › China Industry › Instruments & Meters
China, Chinese Automatic CT PT Analyzer Current Transformer Test Kit for Transformer Testing Equipment1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Test InstrumentComponent TesterCT AnalyzerCT Tester
Wuhan Goldhome Hipot Electrical Co., Ltd.
Preview:
Product Description Automatic ct pt analyzer current transformer test kit for transformer testing equipmentI. Summary:CT PT analyzer is used to measure all kinds of current transformer and voltage transformer. It can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one time test. The tester can automatically evaluate the test results according to the selected standard to determine whether the transformer is qualified.II. Applications:Tests for current transformer:1) Excitation curve and parameters test2) Turns ratio test3) Ratio and phase error test4) Polarity mark check5) Winding resistance measurement6) Secondary loop burden measurement7) Error line curve test for protection CT8) Transient CT parameters test9) CT nameplate guess10) Saturation hysteresis loop curve measurementTests for voltage transformer:1) Turns ratio test2) Ratio error and phase angle error test3) Polarity test4) Secondary burden test5) Winding resistance testIII. Features:1. Make evaluation for test results according to selected standards.2. Make word report for test result.3. Make word reports one time for multi-group test records on the PC.4. Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test.5. Compare excitation curves with saved excitation curves in the same window.IV. Technical parameter1 Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.132 Power supply: AC220V±10%,50Hz/60Hz±10%3 Power output: 0.1~125V (AC)4 Current output: 0.001~5A(RMS)5 Power output:300VA6 Maximum knee voltage measurement; 45kv7 Current measurement:Range:0~10A (automatically change range in 0.1/0.4/2/10A)Error <±0.1%+0.01%FS8 Voltage measurement:Range:0~200 V (automatically change range in 1V/10V/70V/200V)Error < ±0.1%+0.01%FS9 Turns ratio measurement:Range :1~30000,1~1000 error<0.05%1000~2000 error<0.1%2000~30000 error<0.2%10 Phase measurement: error:±2min,resolution:0.01min11 Coil resistance measurement:Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)Error< 0.1%RDG+0.01%FSMaximum resolution:0.1mΩ12 Temperature measurement:-50~100 Celsius degree, error<3 Celsius degree13 CT Secondary burden:Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)Error <0.2%RDG+0.02%FSMaximum resolution 0.001ohm14 PT Secondary burden:Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)Error <0.2%RDG+0.02%FSMaximum resolution: 0.1ohm15 Saved data groups:>1000groups16 Work condition: Temperature:-10oC~50oC, moist:≤90%17 Size: 485mm×356mm×183mm18 Weight: <15KgV. Application field VI. Related products
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...