IPDB › China Industry › Instruments & Meters
China, Chinese Keysight Dsox2022A Digital Oscilloscope 200 MHz 2 Channel Brand New in Stock1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Electronic InstrumentOscilloscopeKeysightOscilloscope
Shenzhen HOBOY Instruments Co., Ltd.
Preview:
Product Description Product ParametersOscilloscope, 2-channel, 200MHz200 MHz. Bandwidth2 Channels1 GSa/s per channel, 2 GSa/s half channel interleaved mode Sample rate100 kpts Memory depth50,000 waveforms update rate per secondWaveGen built-in 20 MHz function generator (Option DSOX2WAVEGEN)Segmented memory (Option DSOX2SGM)Mask limit testing (Option DSOX2MASK) DescriptionBreakthrough technology for budget conscious customersAgilent Technologies is the fastest growing scope vendor in the market for good reason: we deploy our investments in technology to solve your measurement problems. This commitment to superior technology brings you the InfiniiVision X-Series oscilloscopes - engineered to deliver value, functionality and flexibility at prices that fit into your existing budgets. Whether you are looking for a basic entry-level oscilloscope or a more sophisticated model to get your job done, you want the most you can get for your money. The full line of InfiniiVision X-Series oscilloscopes - 26 models - ensure that you get exactly what you need today with room to grow in the future.More scopeThe InfiniiVision 2000 X-Series offers entry-level price points to fit your budget with superior performance and optional capabilities that are not available in any other oscilloscope in its class. Agilent's breakthrough technology delivers more scope for the same budget.Largest displayEngineering for the best signal visibility starts with the largest display. Our 8.5-inch WVGA display offers twice the viewing area with five times the resolution (WVGA 800x480 versus QVGA 320x240).Fastest update rateWith Agilent-designed MegaZoom IV custom ASIC technology, the InfiniiVision 2000 X-Series family delivers up to 50,000 waveforms per second. With this speed you can see signal detail and infrequent anomalies more of the time.Deeper memory for longer time captureWith up to 100 kpts of memory you get 40X more than other scopes in this class, enabling you to capture long, non-repeating signals while maintaining a high sample rate, then quickly zoom in on areas of interest. Deep memory lets the scope maintain a high sample rate over longer time spans. How does Agilent do that?Agilent-designed MegaZoom IV custom ASIC technology combines the capabilities of an oscilloscope, logic analyzer, and WaveGen built-in function generator in a compact form factor at an affordable price. 4th generation MegaZoom technology enables the industry's fastest waveform update rate with responsive deep memory acquisitions. Best-in-class oscilloscopeThe InfiniiVision 2000 X-Series features the deepest memory in its class with 100 kpts of Agilent's patented MegaZoom IV technology that is always enabled and always responsive providing the industry's fastest update rate at up to 50,000 waveforms per second, with no compromise if you turn on measurements or add digital channels.In addition, the 2000 X-Series offers 23 automated measurements such as voltage, time, and frequency as well as four waveform math functions including FFT. All of this at a comparable price to the Tektronix TDS2000C oscilloscope. Industry's first economy-class mixed signal oscilloscope (MSO)The 2000 X-Series is the first instrument in its class to offer an integrated logic timing analyzer. Up until now oscilloscopes in this class have only come with 2 or 4 analog channel options. However, digital content is everywhere in today's designs and traditional 2 and 4 channel oscilloscopes do not always provide enough channels for the job at hand. With an additional 8 integrated digital timing channels, you now have up to 12 channels of time-correlated triggering, acquisition and viewing on the same instrument. Buy a 2 or 4 channel DSO and at any time, upgrade it yourself to a MSO with a license to turn on those integrated 8 digital timing channels. Industry-exclusive WaveGen built-in function generatorAn industry first, the 2000 X-Series offers an integrated 20 MHz function generator. Ideal for educational or design labs where bench space and budget are at a premium, the integrated function generator provides stimulus output of sine, square, ramp, pulse, DC and noise waveforms to your device under test. No need to buy a separate function generator when you can get one integrated in your new oscilloscope. Turn on WaveGen at any time by ordering the DSOX2WaveGen option and install the license yourself.Upgradability:Project needs change, but traditional oscilloscopes are fixed - you get what you pay for at the time of purchase. With the 2000 X-Series, your investment is protected. If you need more bandwidth (up to 200 MHz), digital channels, WaveGen or measurement applications in the future, you can easily add them all after the fact.Mask testingWhether performing pass/fail tests to specified standards in manufacturing or testing for infrequent signal anomalies in R&D debug, the mask test option can be a valuable productivity tool. The 2000 X-Series features the industry's only hardware-based mask testing and can perform up to 50,000 tests per second. Segmented memoryWhen capturing low-duty cycle pulses or data bursts, you can use segmented memory acquisition to optimize acquisition memory. Segmented memory acquisition lets you selectively capture and store important segments of signals without capturing unimportant signal idle/deadtime. Segmented memory acquisition is ideal for applications including packetized serial pulses, pulsed laser, radar bursts and high-energy physics experiments. Up to 25 segments can be captured on the 2000 X-Series models with a minimum re-arm time under 19 μs. Reference waveformsStore up to two waveforms in the scope's non-volatile reference waveform memory locations. Compare these reference waveforms with live waveforms, and perform post analysis and measurements of stored data. You can also store waveform data on a removable USB memory device that can be recalled back into one of the available two reference memories of the scope for full waveform measurement and analysis. Save and/or transfer waveforms as XY data pairs in a comma-separated values format (*.csv) for PC analysis. Save screen images to a PC for documentation purposes in a variety of formats including: 8-bit bitmaps (*.bmp), 24-bit bitmaps (*.bmp), and PNG 24-bit images (*.png).Localized GUI and helpOperate the scope in the language most familiar to you. The graphical user interface, built-in help system, front panel overlays, and user's manual are available in 11 languages. Choose from: English, Japanese, simplified Chinese, traditional Chinese, Korean, German, French, Spanish, Russian, Portuguese and Italian. During operation, access the builtProbe solutionsGet the most out of your 2000 X-Series scope, by using the right probes and accessories for your application. Agilent offers a complete family of innovative probes and accessories for the InfiniiVision 2000 X-Series scopes. AutoscaleQuickly display any active signals and automatically set the vertical, horizontal and trigger controls for optimal viewing with the press of the autoscale button. (This feature can be disabled or enabled for the education environment). ConnectivityBuilt-in USB host (one front, one rear),and USB device ports make PC connectivity easy. A web browser interface allows you to fully operate the scope from your PC and save and recall stored waveforms as well as set-up files via LAN. An optional LAN/VGA module gives you network connectivity if you need it as well as the ability to connect to an external monitor. An optional GPIB module is also available. Only one module may be used at a time. Keep accessories with the scopeA built-in storage compartment allows you to easily keep your probes, power cords and other accessories with the oscilloscope.Designed with education in mindQuickly and easily set up or upgrade a teaching labTeach your students what an oscilloscope is and how to perform basic measurements with the Educator's Oscilloscope Training Kit (DSOXEDK). It includes training tools created specifically for electrical engineering and physics undergraduate students and professors. It contains an array of built-in training signals, a comprehensive oscilloscope lab guide and tutorial written specifically for the undergraduate student, and an oscilloscope fundamentals PowerPoint slide set for professors and lab assistants.Get your students to quickly put the scope to workIntuitive localized front panel design with pushable knobs for quick access to commonly used oscilloscope functions helps students spend more time learning the concepts and less time learning how to use the oscilloscope. Enable your students to answer their own questions with the localized built-in help system that provides quick access by simply pressing and holding any button.Stretch your budget over the long termSave money with an industry-exclusive built-in 20 MHz WaveGen, instead of a separate function generator. Buy what you need today and protect your investment in the future with the only oscilloscopes in this class with upgradable bandwidth, 8 digital channels (MSO), WaveGen and measurement applications. Get long scope life and keep repair costs to a minimum with a standard 3-year warranty, and an instrument reliability you've come to expect from the leader in test and measurement equipment.Optimize lab bench spaceWith 3 instruments in 1, you will save on precious lab bench space by getting an oscilloscope, logic timing analyzer, and WaveGen function generator all in one innovative instrument with a footprint that is only 5.57 inches deep. With the large 8.5-inch WVGA display, you can easily view all signals on one screen with enough viewing area for more than one student to view.Designed with research and development in mindFind more glitches and infrequent eventsWith the fastest architecture in the industry, up to 50,000 aveforms/sec, you can see jitter, infrequent events, and more subtle signal details that other oscilloscopes miss.Capture and view more of your signals at onceWith integrated eight digital timing channels (MSO) models, you can get up to 12 channels of time-correlated triggering, acquisition and viewing on the same instrument with no compromise to the oscilloscopes waveform update rate. Don't need an MSO right now? No problem, just upgrade later when you need it.Optimize lab bench spaceWith 3 instruments in 1, you will save money and precious lab bench space by getting an oscilloscope, logic timing analyzer, and WaveGen function generator all in one innovative instrument with a footprint that is only 5.57 inches deep. With the large 8.5-inch WVGA display, you can easily view all signals on one screen with enough viewing area for more than one engineer to view.Make the most of a limited budgetProject needs change, but traditional oscilloscopes are fixed - you get what you pay for at time of purchase. With the 2000 X-Series, your investment is protected. If you need more bandwidth (up to 200 MHz), 8 digital channels (MSO), WaveGen or measurement applications like mask testing and segmented memory in the future, you can easily add them all when you need to.Designed with manufacturing in mindStretch a limited budgetProtect your investment with the 2000 X-Series. If you need more bandwidth (up to 200 MHz) or measurement applications like mask testing in the future, you can easily add them all when you need them.Get your technicians to quickly put the scope to workIntuitive localized front panel design and pushable knobs for quick access to commonly used oscilloscope functions allow technicians to spend more time testing and less time learning where the menus are on the oscilloscope. Enable your technicians to answer their own questions with the localized built-in help system that provides quick access by simply pressing and holding any button.Faster, low-escape test throughputWith the fastest architecture in its class, featuring up to 50,000 waveforms/sec, you will capture more of those elusive problems you worry about and ensure they don't ship to customers. With the mask limit testing measurement application, you can quickly test up to 50,000 signals per second to a known good waveform with quick go/no-go test results, saving you valuable test time while having more certainty.Optimize test bench spaceWith 3 instruments in 1, you will save on precious line bench space by getting an oscilloscope, logic timing analyzer, and WaveGen function generator all in one innovative instrument with a footprint that is only 5.57 inches deep. With the large 8.5-inch WVGA display, you can easily view all signals on one screen even when the scope is sitting far away from the operator.Manuals/GuidesManualsManualSpec SheetsData SheetOtherQuick Demo GuideProgrammers GuideSegmented Memory AcquisitionMask/Waveform Limit TestingEducators Training KitPower Measurement ApplicationProbes and AccessoriesManufacturer SpecsDSOX2000 Series (digital signal oscilloscope)ModelDSOX2002ADSOX2004ADSOX2012ADSOX2014ADSOX2022ADSOX2024AAnalog Bandwidth* (-3 dB)70 MHz100 MHz200 MHzBandwidth upgradeYESYESNOChannels242424Sample rate on each channelSample rate on each channelMemory depth (record length)100 kptsDisplay8.5-inch WVGA with 64 levels of intensity gradingWaveform update rate50,000 waveforms/sExternal trigger inputIncluded on all modelsVertical resolution8 bitsHorizontal resolution2.5 psVertical sensitivity (range)2 mV/div to 5 V/div **DC vertical accuracy±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale] **DC vertical gain accuracy*±3% full scale (= 10 mV/div); ±4% full scale (< 10 mV/div) **DC vertical offset accuracy±0.1div ± 2mV ± 1% of offset settingVertical zoomAbility to scale and position a live or stopped waveform vertically. When the acquisition is stopped, turning the vertical scale and offset (position) knobs will scale and move the signal. Pan and zoom redraws the waveform in < 100 ms.Maximum input voltageCAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpkCAT II 300 Vrms, 400 Vpk with N2862A or N2863A 10:1 probe: 300 VrmsPosition range/offset2 mV to 200 mV/div: ±2 V >200 mV to 5 V/div: ± 50VBandwidth limit20 MHz selectableInput couplingAC, DC, GNDInput impedance1 MΩ ±2%Time base range5 ns/div to 50 s/div5 ns/div to 50 s/div2 ns/div to 50 s/divTime base accuracy*25 ppm ±5 ppm per year (aging)Time accuracy (using cursors)± (time base * reading) ± (0.0016 * screen width) ± 100 psDynamic range(±8 divisions from center screen)Horizontal zoom (modes)Horizontally expand or compress a live or stopped waveform* Denotes warranted specifications, all others are typical.Specifications are valid after a 30-minute warm-up period and from ±10 °C firmware calibration temperature.** 2 mV/div is a magnification of 4 mV/div setting. For vertical accuracy calculations, use full scale of 32 mV for 2 mV/div sensitivity setting. Acquisition modesNormalPeak detectCapture glitch as narrow as 500 ps at all timebase settings.AveragingSelect from 2,4,8,16, 64... to 65,536High resolution mode12 bits of resolution when ≥ 20 μs/divSegmentedRe-arm time= 19 μs (minimum time between trigger events) Trigger systemTrigger couplingCoupling selections: AC, DC, noise reject, LF reject and HF reject.Trigger modesEdge (rising/falling alternate, either)-Conventional level-driven trigger.Pulse width (or glitch)-Trigger on a pulse width less than, greater than, or within a time range, with a selectable time limit ranging from 17 ns to 10 s.Pattern-trigger on a logical AND combination of the channels. Each channel can have a value of zero, one, don't care (X), or a rising or falling edge (one channel only).Video-Trigger on all lines or individual lines, odd/even or all fields from composite video or broadcast standards (NTSC, PAL, PAL-M, SECAM).Trigger sourceEach analog channel, each digital channel (MSO models or DSOX2MSO upgrade, Ext, WaveGen, line)Trigger sensitivity (internal)*< 10 mV/div: greater of 1 div or 5 mV; ≥ 10 mV/div: 0.6 divTrigger sensitivity (external)*200 mV (DC to 100 MHz); 350 mV (100 MHz - 200 MHz) CursorsTypesAmplitude, time , frequency (FFT), manual, tracking, binary, HEXMeasurementsΔT, 1/ΔT, ΔV/X, 1/ΔX, ΔYCursors**Single cursor accuracy: ±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]Dual cursor accuracy: ±[DC vertical gain accuracy + 0.5% full scale]* Automatic waveforms measurementsVoltageSnapshot all, maximum, minimum, peak-to-peak, top, base, amplitude, overshoot, preshoot, average- N cycles, average-full screen, DC RMS- N cycles, DC RMS- full screen, AC RMS- N cyclesTimePeriod, frequency, rise time, fall time, + width, - width, duty cycle, delay A→B (rising edge), delay A→B (falling edge), phase A→B (rising edge,) and phase A→B (falling edge)* Denotes warranted specifications, all others are typical.Specifications are valid after a 30-minute warm-up period and from ±10 °C firmware calibration temperature** 2 mV/div is a magnification of 4 mV/div setting. For vertical accuracy calculations, use full scale of 32 mV for 2 mV/div sensitivity setting. Waveform mathOperatorsAdd, subtract, multiply, FFTFFT WindowsHanning, flat top, rectangular; Blackman-HarrisSourcesAnalog channels 1 and 2, analog channels 3 and 4 Display characteristicsDisplay8.5-inch WVGAResolution800 (H) x 480 (V) pixel format (screen area)InterpolationSin(x)/x interpolation (using FIR filter; used when there is less than one sample per column of the display)PersistenceOff, infinite, variable persistence (100ms-60s)Intensity gradation64 intensity levels MSO (digital channels)Upgradable from DSOYesMSO channels8 channels (D0 to D7)MSO sample rate1 GSa/sThreshold selectionsTTL (+1.4 V), CMOS (+2.5 V), ECL (-1.3 V), User-definable (±8.0 V in 10 mV stops)Threshold accuracy*± (100 mV + 3% of threshold settings)Maximum input dynamic range±10 V about thresholdMinimum voltage swing500 mVppInput impedance100 kΩ ± 2% at probe tip, ~8 pFMinimum detectable pulse width5nsChannel-to-channel skew2 ns (typical), 3 ns (maximum) Environmental and safetyTemperatureOperating: 0 to +55 °CNon-operating: -40 to +71 °CHumidityOperating: Up to 80% RH at or below +40 °C; up to 45% RH up to +50 °CNon-operating: Up to 95% RH up to 40 °C; up to 45% RH up to 50 °CAltitudeOperating and non-operating: up to 4,000 mElectromagnetic compatibilityMeets EMC Directive (2004/108/EC), meets or exceeds IEC 61326-1:2005/EN61326-1:2006 Group 1 Class A requirementCISPR 11/EN 55011IEC 61000-4-2/EN 61000-4-2IEC 61000-4-3/EN 61000-4-3IEC 61000-4-4/EN 61000-4-4IEC 61000-4-5/EN 61000-4-5IEC 61000-4-6/EN 61000-4-6IEC 61000-4-11/EN 61000-4-11Canada: ICES-001:2004Australia/New Zealand: AS/NZSSafetyUL61010-1 2nd edition, CAN/CSA22.2 No. 61010-1-04* Denotes warranted specifications, all others are typical.Specifications are valid after a 30-minute warm-up period and from ±10 °C firmware calibration temperature. WaveformsSine, square, pulse, triangle, ramp, noise, DCSineFrequency range: 0.1 Hz to 20 MHzAmplitude flatness: ±0.5 dB (relative to 1 kHz)Harmonic distortion: -40 dBcSpurious (non harmonics): -40 dBcTotal harmonic distortion: 1%SNR (50 ohm load, 500 MHz BW) : 40 dB (Vpp = 0.1 V); 30 dB (Vpp <0.1 V)Square wave/pulseFrequency range: 0.1 Hz to 10 MHzDuty cycle: 20 to 80%Duty cycle resolution: Larger of 1% or 10 nsPulse width: 20 ns minimumPulse width resolution: 10 ns or 5 digits, whichever is largerRise/fall time: 18 ns (10 to 90%)Overshoot: < 2%Asymmetry (at 50% DC): ±1% ± 5 nsJitter (TIE RMS): 500 psRamp/triangle waveFrequency range: 0.1 Hz to 100 kHzLinearity: 1%Variable symmetry: 0 to 100%Symmetry resolution: 1%NoiseBandwidth: 20 MHz typicalFrequencySine wave and ramp accuracy:130 ppm (frequency < 10 kHz)50 ppm (frequency > 10 kHz)Square wave and pulse accuracy:[50+frequency/200] ppm (frequency < 25 kHz)50 ppm (frequency = 25 kHz)Resolution: 0.1 Hz or 4 digits, whichever is largerAmplitudeRange:20 mVpp to 5 Vpp into Hi-Z10 mVpp to 2.5 Vpp into 50 ohmsResolution: 100 μV or 3 digits, whichever is largerAccuracy: 2% (frequency = 1 kHz)DC offsetRange:±2.5 V into Hi-Z±1.25 V into 50 ohmsResolution: 100 μV or 3 digits, whichever is largerAccuracy: ±1.5% of offset setting ±1.5% of amplitude ±1 mVTrigger outputTrigger output available on Trig out BNC InstrumentDimensionsmmInchesWidth380.614.98Height204.48.05Depth141.55.57WeightkglbInstrument only3.858.5With accessories4.089.0Instrument shipping - package dimensionsmmInchesWidth45017.7Height2509.84Depth36014.17Rack mountmmInchesWidth481.618.961Height221.58.72Depth189.347.454 ConnectivityStandard portsOne USB 2.0 high-speed device port on rear panelTwo USB 2.0 high-speed host ports, front and rear panelSupports memory devices and printersOptional portsGPIB, LAN, VGA Nonvolatile storageReference waveform display2 internal waveforms or USB thumb driveWaveform storageSet up, .bmp, .png, .csv, ASCII, XY, reference waveforms, .alb, .bin, lister, maskMax USB flash drive sizeSupports industry standard flash drivesSet ups without USB flash drive10 internal setupsSet ups with USB flash driveLimited by size of USB driveTech SpecsOscilloscopes/Digital Oscilloscopes TemplateBandwidth200 MHzChannels2Sampling Rate2 GS/SMemory8 kBRise Time18 nsScreen Size12.1 INBits8Test Equipment General AttributesUnique FeaturesBest-in-class oscilloscopeIntegrated logic analyzer (MSO, Optional and upgradable with DSOX2MSO)Only built-in 20-MHz function generator: WaveGenWarranty3 YEARSWarranty DetailsReturn to Agilent Warranty - 3 yearsInterfaces I/OAnalog Output, GPIB, LAN / Ethernet, LXI, Web Host / Web Server, Analog Input StorageCompact FlashProduct Weight9 LBSProduct Height5.57 INProduct Length14.98 INProduct Width8.05 INData LoggingYesCalibration IncludedNIST Calibration Power Supply Voltage120V/220V UniversalCountry of OriginUnited States s an important international instrument sales platform, our company has the authorization qualifications of many international first-line brands. Relying on the advanced digital information management platform and international procurement platform, we provide more than 100,000 instruments, industrial MRO products, industrial products and spare parts to global customers. Our business scope: industrial testing, non-destructive testing, gas testing, electrical testing, laboratory testing, water quality testing, environmental testing, medical testing... So far, we have become an important partner of many global top 500 companies and well-known local Chinese companies. Create an efficient supply chain system to provide customers with strong supply guarantee. Packaging & Shipping As an important international instrument sales platform, our company has the authorization qualifications of many international first-line brands. Relying on the advanced digital information management platform and international procurement platform, we provide more than 100,000 instruments, industrial MRO products, industrial products and spare parts to global customers. Our business scope: industrial testing, non-destructive testing, gas testing, electrical testing, laboratory testing, water quality testing, environmental testing, medical testing... So far, we have become an important partner of many global top 500 companies and well-known local Chinese companies. Create an efficient supply chain system to provide customers with strong supply guarantee.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...