IPDB › China Industry › Instruments & Meters
China, Chinese Acrel LCD Display Can Connect To8 Three-Phase Accircuits at The Same Time Power Collection and Monitoring Device Amc200L-8e3/4G1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Meter for ElectricityOther Meters for ElectricityMulti-Loop Intelligent Power MeterCollection and Monitoring Device
ACREL CO., LTD.
Preview:
Product Description Product DescriptionAMC200(L) DC multi-circuit intelligent power acquisition and monitoring device is mainly used for the full electrical parameter measurement of multiple circuits, and can be connected to the current input of up to 12 single-phase DC circuits at the same time. It can directly measure parameters such as voltage, current and power. Product ParametersTechnical ParameterTechnical IndicatorInputDC VoltageOne channel:DC -48VDC Current12 Channels Hall Current Sensor:Hall sensor secondary side DC 5V accessState Grid MonitoringOne channel:DC 0-5VOverloadVoltage: 1.2 times for 1 second, 2 times for 1 second; Current: 1.2 times for 1second, 10 times for 1 secondFrequencyVoltage,Current Class 0.5,Power Class 1.0ResolutionThe voltage output accuracy is 0.01V, the current output accuracy is 0.01A, thepower output accuracy is 0.01kW, and the power output accuracy is 0.01kWhFunctionBasic FunctionMonitoring equipment system time, total voltage, total output current, total power, total electrical energy, voltage of each sub channel, current of each sub channel, power of each sub channel, electrical energy of each sub channel; RS485 communicationAlarm FunctionDC voltage output too low alarm, DC voltage output too high alarm, one-time power-off alarm, module voltage loss alarm, metering sub channel error alarm, internal program error alarm, clock error alarm, memory unit failure alarm, AC input power failure alarmTiming functionSupport broadcast timing, remote timing calibration of metering module can be carried out through RS485 communication interfaceCommunicationSingle-channel RS485, the default baud rate is 9600bps, and can be set to 1200-9600bps. Communication protocol: YD/T1363 protocol or Modbus RTU protocolHall power supplyA set of ±12V power outputHumidity AndTemperature4 Channels NTC Temperature Monitoring:Temperature:-20-100oC(Accuracy±2oC)Humidity:20-90%RH(Accuracy ±5%RH)AuxiliarypowerVoltage RangeDC -40V~-60VPower consumptionThe whole device≤2W (without Hall power supply output)StorageIt has the storage function of historical energy data and historical alarminformationInsulation resistance≥40MΩEnvironmentTemperatureWorking Temperature:-20oC~+60oC;Storage Temperature:-40oC~+70oCHumidity≤98% no condensation, no corrosive gas placeAltitude≤4000m
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...