IPDB › China Industry › Instruments & Meters
China, Chinese 30m 0.25mm 0.33um Gas Chromatograph Capillary Gc Column for Oxide Detection1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Analysis InstrumentChromatographySpectroscopy InstrumentGc Capillary ColumnChromatography Column
Jiangxi Aiyi High Tech Co., Ltd.
Preview:
Product Description Product DescriptionApplication Area* Alcohols, aromatics, amines* Drugs of Abuse, flavours, fatty acids* Halogenated hydrocarbons, hydrocarbons* PAHs, Phthalates (EPA Method 606)* Natural Gas* Cyclic Hydrocarbons* Pesticides, solventsColumn length/mInner diameter/mmFilm thickness/um 15m0.25mm0.33um 0.53mm1.00um 30m0.25mm0.33um 0.25mm0.50um 0.25mm1.00um 0.25mm1.40um 0.32mm0.33um 0.32mm0.50um 0.32mm1.00um 0.32mm1.80um 0.53mm0.50um 0.53mm1.00um 0.53mm3.00um 50m0.25mm0.25um 0.25mm0.33um 0.25mm0.50um 0.25mm1.00um 0.32mm0.25um 0.32mm0.33um 0.32mm0.50um 0.32mm1.00um 0.32mm3.00um 60m0.25mm0.25um 0.25mm0.33um 0.25mm0.50um 0.25mm1.00um 0.32mm0.25um 0.32mm0.33um 0.32mm0.50um 0.32mm1.00um 0.32mm1.80um 0.32mm3.00um Detailed PhotosHow to choose a right capillary column?1. Column lengthThe resolution is proportional to the square root of the column length. Under other conditions unchanged, 4 times the column length is required to obtain doubled resolution. Shorter columns are suitable for simpler samples, especially those composed of components that differ greatly in structure, polarity, and volatility. 15m short column is used to quickly separate simpler samples and is also suitable for scanning analysis; 30m chromatographic column is the commonly used column length, most of the analysis is done on this length of the column; 50m/60m or longer chromatographic columns are used to separate more complex samples.2. Column inner diameterThe inner diameter of the column directly affects the efficiency, retention characteristics and sample capacity of the column. Small-bore columns have higher efficiency than large-bore columns, but the column capacity is smaller0.25mm: Has higher column efficiency and lower column capacity. It is better to separate complex samples.0.32mm: The column efficiency is slightly lower than 0.25mm, but the column capacity is about 60% higher.0.53mm: It has a column capacity similar to a packed column and can be used for split injection or splitless injection.When performing trace analysis, a large-bore capillary column is more appropriate.3. Liquid film thicknessThe thickness of the liquid film affects the retention characteristics and capacity of the column. As the thickness increases, the retention time also increases.0.1-0.2um: The thin liquid film capillary column elutes components faster than the thick liquid film capillary column, the required column temperature is lower, and the column loss is smaller at high temperature, which is suitable for the analysis of high boiling point compounds. 0.25-0.5um: commonly used liquid film thickness. 0.6-5.0urn: thick liquid film, which is more advantageous for the analysis of low boiling point compounds.Packaging & Shipping Company ProfileFounded in 2015, Jiangxi Aiyi High-Tech Co., Ltd. is located in Nanchang, a beautiful hero city. It is a professional company integrated R&D, design, manufacturing and sales of a full range of laboratory instruments and consumables. Aiyi is a one-stop supplier and service provider of laboratory instruments and laboratory consumables. The company's main business varieties are: laboratory basic equipment, analytical instruments, optical instruments, environmental protection equipment, electronic equipment, medical equipment. The company's products are widely used at home and abroad: colleges and universities, research institutes, chemical, pharmaceutical, environmental protection, petroleum, food, light industry and other fields. Provide them with advanced equipment and technical support.CertificationsFAQ1. who are we?We are based in Jiangxi, China, start from 2015,sell to Domestic Market(45.00%),Southeast Asia(15.00%),North America(10.00%),South Asia(5.00%),Eastern Europe(5.00%),Western Europe(5.00%),South America(4.00%),Eastern Asia(3.00%),Southern Europe(3.00%),Northern Europe(3.00%),Mid East(2.00%). There are total about 11-50 people in our office.2. how can we guarantee quality?Always a pre-production sample before mass production;Always final Inspection before shipment;3.what can you buy from us?Chromatographic instruments, biochemical instruments, laboratory cabinets, physical and physical optical instruments, spectroscopic instruments4. why should you buy from us not from other suppliers?Stability and reliability, energy saving and environmental protection, intelligent innovation are our own core technology, and we also have years of professional R & D design, equipment production, instrument maintenance experience5. what services can we provide?Accepted Delivery Terms: FOB;Accepted Payment Currency:USD,EUR,GBP,CNY;Accepted Payment Type: T/T,L/MoneyGram, Credit Card, Western Union, Cash, Escrow;Language Spoken: English, Chinese
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...