IPDB › China Industry › Instruments & Meters
China, Chinese Fluke 123b Industrial Scopemeter Hand-Held Oscilloscope, 20 MHz1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Electronic InstrumentOscilloscope20 MHzFlukeOscilloscope
Shenzhen HOBOY Instruments Co., Ltd.
Preview:
Product Description Product ParametersFluke 123B/NA 20 MHz, 2-Channel, 40 MS/s Industrial ScopeMeter Hand-Held Oscilloscope with Fluke Connect Compatibility123B/NA Industrial ScopeMeter Handheld Oscilloscope 20MHz (North America)Dual-input digital oscilloscope and multimeter20 MHz oscilloscope bandwidthTwo 5,000-count true-rms digital multimetersConnect-and-View? trigger simplicity for hands-off operationIntellaSet? technology automatically and intelligently adjusts numerical readout based on the measured signalDual-input waveform and meter reading recorder for trending data over extended periodsRecorder Event Detect captures elusive intermittent signals on repetitive waveforms up to 4 kHzShielded test leads for oscilloscope, resistance and continuity measurementsResistance, continuity, diode and capacitance meter measurementsPower measurements (W, VA, VAR, PF, DPF, Hz)Voltage, current and power harmonicsCheck Industrial networks with BusHealth physical layer tests against defined reference levelsSave or recall data and instrument setupsStore instrument setups defined by a test sequence for routine maintenance or most often used test procedures.External optically isolated USB interface to transfer, archive and analyze scope or meter dataOptional WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect? mobile app*FlukeView? ScopeMeter? Software for Windows?Rugged design to withstand 3g Vibration, 30g shock, and rated IP51 according to EN/IEC60529Highest safety rating in the industry: safety rated for CAT IV 600 VLi-Ion rechargeable battery, seven-hours operation (with four-hour charge time)View Product Details Manufacturer SpecsFluke 120B Series SpecificationsOscilloscope modeVerticalFrequency response - dccoupledWithout probes and test leads(with BB120)123B: dc to 20 MHz (-3 dB)124B and 125B: dc to 40 MHz (-3dB)With STL120-IV 1:1 shielded testleadsDC to 12.5 MHz (-3 dB) / dc to 20MHz (-6 dB)With VP41 10:1 Probe123B: dc to 20MHz (-3 dB)124B and 125B: dc to 40 MHz (-3dB)Frequency response - accoupled (lf roll off)Without probes and test leads<10 Hz (-3 dB)With STL120-IV 1:1 shielded testleads<10 Hz (-3 dB)With VP41 10:1 Probe<10 Hz (-3 dB)Rise time, excluding probes,test leads123B <17.5 ns124B and 125B <8.75 nsInput impedanceWithout probes and testleads1 MΩ//20 pFWith BB1201 MΩ//24 pFWith STL120-IV 1:1 shielded testleads1 MΩ//230 pFWith VP41 10:1 Probe5 MΩ//15.5 pFSensitivity5 mV to 200 V/divAnalog bandwidth limiter10 kHzDisplay modesA, -A, B, -BMax. input voltage A and BDirect, with test leads, or withVP41 Probe600 Vrms Cat IV, 750 Vrmsmaximum voltage.With BB120600 VrmsMax. floating voltage, from anyterminal to ground600 Vrms Cat IV, 750 Vrms up to 400HzHorizontalScope modesNormal, Single, RollRanges (normal)Equivalent sampling123B: 20 ns to 500 ns/div,124B and 125B: 10 ns to 500ns/divReal time sampling1 μs to 5 s/divSingle (real time)1 μs to 5 s/divRoll (real time)1s to 60 s/divSampling rate (for bothchannels simultaneously)Equivalent sampling (repetitivesignals)Up to 4 GS/sReal time sampling 1 μs to 60s/div40 MS/sTriggerScreen updateFree run, on triggerSourceA, BSensitivity A and B@ DC to 5 MHz0.5 divisions or 5 mV@ 40 MHz123B: 4 divisions124B and 125B: 1.5 divisions@ 60 MHz123B: N/A124B and 125B: 4 divisionsSlopePositive, negativeAdvanced scope functionsDisplay modesNormalCaptures up to 25 ns glitches anddisplays analog-like persistencewaveformSmoothSuppresses noise from a waveformGlitch offDoes not capture glitches betweensamplesEnvelopeRecords and displays the minimumand maximum of waveforms overtimeAuto set (Connect-and-View?)Continuous fully automatic adjustments of amplitude, time base, triggerevels, trigger gap, and hold-off. Manual override by user adjustment ofamplitude, time base, or trigger level.Dual input meterThe accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C.Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1probe, add probe uncertainty +1%. More than one waveform period must be visible on the screen.Input A and input BDC voltage (VDC)Ranges500 mV, 5 V, 50 V, 500 V, 750 VAccuracy±(0.5% +5 counts)Common mode rejection(CMRR)>100 dB @ dc, >60 dB @ 50, 60, or 400 HzFull scale reading5000 countsTrue-rms voltages (V ac and V ac+dc)Ranges500 mV, 5 V, 50 V, 500 V, 750 VAccuracy for 5% to 100% of range(DC coupled)DC to 60 Hz (V ac+dc)±(1% +10 counts)1 Hz to 60 Hz (V ac)±(1% +10 counts)Accuracy for 5% to 100% of range(AC or dc coupled)60 Hz to 20 kHz±(2.5% +15 counts)DC rejection (only VAC)>50 dBCommon mode rejection(CMRR)>100 dB @ dc>60 dB @ 50, 60, or 400 HzFull scale reading5000 counts, reading is independent of any signal crest factor.PeakModesMax peak, Min peak, or pk-to-pkRanges500 mV, 5 V, 50 V, 500 V, 2200 VAccuracyAccuracy Max peak or Min peak5% of full scaleAccuracy Peak-to-Peak10% of full scaleFull scale reading500 countsFrequency (Hz)Ranges123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz,and 50 MHz124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz,10 MHz, and 70 MHzFrequency range15 Hz (1 Hz) to 50 MHz in continuous autosetAccuracy @1 Hz to 1 MHz±(0.5% +2 counts)Full scale reading10,000 countsRPMMax reading50.00 kRPMAccuracy±(0.5% +2 counts)Duty cycle (PULSE)Range2% to 98%Frequency range15 Hz (1 Hz) to 30 MHz in continuous autosetPulse width (PULSE)Frequency range15 Hz (1 Hz) to 30 MHz in continuous autosetFull scale reading1000 countsAmperes (AMP)With current clampRangesSame as V dc, V ac, V ac+dc, orPEAKScale factors0.1 mV/A, 1 mV/A, 10 mV/A, 100mV/A, 400 mV/A, 1 V/A, 10mV/mAAccuracySame as V dc, V ac, V ac+dc, orPEAK (add current clampuncertainty)Temperature (TEMP) with optional temperature probeRange200 °C/div (200 °F/div)Scale factor1 mV/°C and 1 mV/°FAccuracyAs V dc (add temp. probe uncertainty)Decibel (dB)0 dBV1 V0 dBm (600 Ω /50 Ω)1 mW referenced to 600 Ω or 50 ΩdB onV dc, V ac, or Vac+dcFull scale reading1000 countsCrest factor (CREST)Range1 to 10Full scale reading90 CountsPhaseModesA to B, B to ARange0 to 359 degreesResolution1 degreePower (125B only)Configurations1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamentalcomponent only, AUTOSET mode only)Power factor (PF)Ratio between watts and VA range - 0.00 to 1.00WattRMS reading of multiplying corresponding samples of input A (volts)and input B (amperes)Full scale reading999 countsVAVrms x ArmsFull scale reading999 countsVA reactive (var)v((VA)2-W2)Full scale reading999 countsVpwmPurposeTo measure on pulse width modulated signals, like motor drive inverteroutputsPrincipleReadings show the effective voltage based on the average value ofsamples over a whole number of periods of the fundamental frequencyAccuracyAs Vrms for sinewave signalsInput A to commonOhm (Ω)Ranges123B and 124B500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ125B50 Ω, 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩAccuracy±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)Full scale reading50 O to 5 MΩ - 5000 counts, 30 MΩ - 3000 countsMeasurement current0.5 mA to 50 nA, decreases with increasing rangesOpen circuit voltage<4 VContinuity (Cont)Beep<(30 O ±5 Ω ) in 50 Ω rangeMeasurement current0.5 mADetection of shorts of=1 msDiodeMeasurement voltage@0.5 mA>2.8 V@open circuit<4 VMeasurement current0.5 mAPolarity+ on input A, - on COMCapacitance (CAP)Ranges50 nF, 500 nF, 5 μF, 50 μF, 500 μFFull scale reading5000 countsMeasurement current500 nA to 0.5 mA, increases with increasing rangesAdvanced meter functionsZero SetSet actual value to referenceAutoHold (on A)Captures and freezes a stable measurement result. Beeps when stable.AutoHold works on the main meter reading, with thresholds of 1 Vppfor AC signals and 100 mV for DC signals.Fixed decimal pointActivated by using attenuation keysCursor Readout (124B and 125B)SourcesA, BSingle vertical lineAverage, min and max readoutAverage, min, max and time from start of readout (in ROLL mode;instrument in HOLD)Min, max and time from start of readout (in RECORDER mode;instrument in HOLD)Harmonics values in POWER QUALITY mode.Dual vertical linesPeak-peak, time distance and reciprocal time distance readoutAverage, min, max and time distance readout (in ROLL mode; instrument in HOLD)Dual horizontal linesHigh, low and peak-peak readoutRise or fall timeTransition time, 0%-level and 100%-level readout (manual or autoleveling; auto leveling onlypossible in single channel mode)AccuracyAs oscilloscope accuracyRecorderThe recorder captures meter readings in Meter Recorder mode or continuously captures waveform samplesin Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the125B or 124B).The results are displayed as Chart recorder display that plots a graph of min and max values of Metermeasurements over time or as a waveform recorder display that plots all the captured samples.Meter readingsMeasurement SpeedMaximum 2 measurement/sRecord Size (min, max, average)2 M readings for 1 channelRecorded Time Span2 weeksMaximum number of events1024Waveform recordMaximum sample rate400 K sample/sSize Internal memory400 M samples Recorded TimeSpan internal memory15 minutes at 500 μs/div11 hours at 20 ms/divRecord Size SD card1.5 G samplesRecorded Time Span SD card11 hours at 500 μs/div14 days at 20 ms/divMaximum number of events64Power Quality (125B only)ReadingsWatt, VA, var, PF, DPF, HzWatt, VA, var ranges (auto)250 W to 250 MW, 625 MW, 1.56 GWWhen selected: total (% r)±(2% + 6 counts)When selected: fundamental (% f)±(4% + 4 counts)DPF0.00 to 1.00PF0.00 to 1.00, ±0.04Frequency range10.0 Hz to 15.0 kHz40.0 Hz to 70.0 HzNumber of HarmonicsDC to 51Readings / Cursor readings(fundamental 40 Hz to 70 Hz)Vrms / Arms /WattEach harmonic from fundamentalmaybe selected for individualreadingsIncludes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)BusHealth tester (Fluke 125B only)TypeSubtypeProtocolAS-iNEN-EN50295CANISO-11898Interbus SRS-422EIA-422ModbusRS-232RS-232/EIA-232RS-485RS-485/EIA-485Foundation FieldbusH161158 type 1, 31.25 kBitProfibusDPEIA-485PA61158 type 1MiscellaneousDisplayType5.7-inch color active matrix TFTResolution640 x 480 pixelsWaveform DisplayVertical10 div of 40 pixelsHorizontal12 div of 40 pixelsPowerExternalVia Power Adapter BC430Input voltage10 V DC to 21 V DCPower consumption5 W typicalInput connector5 mm jackInternalVia Battery Pack BP290Battery powerRechargeable Li-Ion 10.8 VOperating time7 hours with 50% backlight brightnessCharging time4 hours with test tool off, 7 hours with test tool onAllowable ambient temp0 to 40 °C (32 to 104 °F) during chargingMemoryInternal memory can store20 data sets (screenwaveform and setup)Micro SD card slot with optional SD card (max size of 32 GB)MechanicalSize259 x 132 x 55 mm(10.2 x 5.2 x 2.15 in)Weight1.4 kg (3.2 lb) including battery packInterfaceOptically isolatedTransfer screen copies (bitmaps), settings and dataUSB to PC/laptopOC4USB optically isolated USB adapter/cable, (optional), usingFlukeView? software for Windows?.Optional WiFi adapterFast transfer of screen copies (bitmaps), settings and data toPC/laptop, tablet, smartphone, etc. A USB port is provided forattaching the WiFi dongle. Do not use the USB port with a cablefor safety reasons.EnvironmentalEnvironmentalMIL-PRF-28800F, Class 2TemperatureBattery Operation0 to 40 °C (32 to 104 °F)Power Adapter Operation0 to 50 °C (32 to 122 °F)Storage-20 to 60 °C (-4 to 140 °F)Humidity (Operating)@ 0 to 10 °C (32 to 50 °F)Non-condensing@ 10 to 30 °C (50 to 86 °F)95%@ 30 to 40 °C (86 to 104 °F)75%@ 40 to 50 °C (104 to 122 °F)45%Storage@ -20 to 60 °C (-4 to 140 °F)Non-condensingAltitudeOperating at 3 km (10,000 feet)CAT III 600 VOperating at 2 km (6,600 feet)CAT IV 600 VStorage12 km (40,000 feet)EMC electromagneticcompatibilityInternationalIEC 61326-1: Industrial, CISPR 11: Group 1,Class AKorea (KCC)Class A Equipment (Industrial Broadcasting &Communication Equipment)USA (FCC)47 CFR 15 subpart B. This product isconsidered an exempt device per clause15.103.Wireless radio withadapterFrequency range2412 MHz to 2462 MHzOutput power<100 mWEnclosure protectionIP51, ref: EN/IEC60529SafetyGeneralIEC 61010-1: Pollution Degree 2MeasurementIEC 61010-2-033: CAT IV 600 V/CAT III 750 VMax. input voltage inputA and BDirect on input or with leads600 Vrms CAT IV for deratingWith Banana-to-BNC AdapterBB120600 Vrms for deratingMax. floating voltage fromany terminal to ground600 Vrms Cat IV, 750 Vrms up to 400 HzTech SpecsMultimeters TemplateStyleHand-HeldMeasures AC VYesMeasures DC VYesMeasures AC ANo Measures DC ANo True RMSYesMaximum Voltage AC750 VMaximum Voltage DC750 VBasic Accuracy V DC±(0.5 % + 5 counts)Counts5000 .BacklightYesManual/AutorangingBothDecibelsYesResistanceYes FrequencyYes CapacitanceYes TemperatureNo Diode TestingYesCAT RatingIV CAT Voltage600 VIntrinsically SafeNoPeak HoldNo Overload ProtectorNoKelvin 4-Wire Measurement CapabilityNoWireless DisplayNoData HoldNoLow-Pass FilterNoDuty Cycle %2 % to 98 %Oscilloscopes/Portable Oscilloscopes TemplateBandwidth20 MHzChannels2Sampling Rate40 MS/S Screen Type (Oscilloscopes)TFT/LCDIsolated InputsNoScreen Size5.7 INColor ScreenYesRise Time8.75 nsMemory400 MP [megapoints] (409600 kB)Test Equipment General AttributesUnique FeaturesPower measurements (W, VA, VAR, PF, DPF, Hz)Dual-input digital oscilloscope and multimeter.Warranty3 YEARSSafety ApprovalCE, CSAInterfaces I/OUSB StorageInternal Memory, Micro SDIP RatingIP51Product Weight1.4 KILOS (3.09 LBS)Product Height2.15 INProduct Length10.2 INProduct Width5.2 INData LoggingYesCalibration IncludedNoneBattery TypeLi-ionPower Supply VoltageBattery PoweredCountry of OriginRomania Packaging & Shipping As an important international instrument sales platform, our company has the authorization qualifications of many international first-line brands. Relying on the advanced digital information management platform and international procurement platform, we provide more than 100,000 instruments, industrial MRO products, industrial products and spare parts to global customers. Our business scope: industrial testing, non-destructive testing, gas testing, electrical testing, laboratory testing, water quality testing, environmental testing, medical testing... So far, we have become an important partner of many global top 500 companies and well-known local Chinese companies. Create an efficient supply chain system to provide customers with strong supply guarantee.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...