IPDB › China Industry › Instruments & Meters
China, Chinese Low Price Durable Industrial Turbine Flowmeter Measurement for Power Generation1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Meter for Liquid GasFlow MeterIndustrial Turbine FlowmeterTurbine Flowmeter Measurement
Wuhu Schalod Technology Co., Ltd
Preview:
Product DescriptionProduct DescriptionTURBINE FLOWMETERThe MPWY Paddlewheel Flow Sensor offers simple installation, reliable performance, durability, repeatability, ruggedness, little or no maintenance, and exceptional value.The MPWY model has a sinusoidal output signal and is capable of driving a self-powered flow meter. A wide dynamic flow range of 0.3 to 10 m/s enables the sensor to measure liquid flow rates in full pipelines and can be used in low-pressure systems. Model MPWY sensors are available for a wide range of pipe sizes and can be installed in pipes up to DN65 using a variety of custom fittings. When the power is turned on, the green LED will light up and flash proportionally to the rotation frequency of the paddlewheel. The red LED illuminates to indicate a device malfunction. The paddlewheel rotates as liquid flows into the pipe. A non-wetted permanent magnet mounted in the paddlewheel generates a measurement signal whose frequency is proportional to the flow rate.COST-EFFECTIVE METERING SOLUTION FAST RESPONSE TIMEWIDE FLOW RANGE AND TURNDOWN RATIO Delivers a superior price-to-performance ratio, providing high accuracy and reliability at a more affordable cost compared to many other high-precision meter technologies.The rotor reacts almost instantly to changes in flow, providing real-time data that is essential for dynamic process control and fast-acting safety systems.A single turbine meter can accurately measure a wide range of flow rates, providing excellent performance in systems with varying flow conditions.Product ParametersNORMGeneralScope Of Work0.3 To 10 M/SPipe Size RangeDN06 To DN65Biometrics±0.5% Of Maximum Range @ 25 °C (77 °F)Repetitive±0.4% Of Maximum Range @ 25 °C (77 °F)Moisturizing MaterialMountingStainless SteelsO-RingFKM , Optional EPDMShafts And BearingsZrO2Toggle, BracketPVDFElectronicOperating Voltage12... .36 VDC ±10%, Filtered And RegulatedCurrent Consumption<60 MA (12 VDC Without Load In Current Version)Source ImpedanceMaximum Loop Impedance: 1125 At 36 VDC, 650 At 24 VDC, 140 At 12 VDCCable TypeMaximum Cross Section 1.5 Mm2Maximum Rated Temperature/Pressure - Standard SensorsStainless SteelsPN16 (232 PSI) With Metal FittingsOperating TemperatureStainless SteelsStainless Steel: -15... +100 °C(+5... +212 °F) (If Ambient Temperature Is ≤ +45 °C) Or -15... +90 °C (+5... +194 °F)(If +45 °C ≤ T° Ambient Temperature ≤ +60 °C)REGISTER DESCRIPTIONSystem Parameter Register Address: Support Function Code 03H: HOLDING REGISTER, Float CD AB format. USHORT=Unsigned 16bits, FLOAT=32-bit floating point number.Register AddressSports EventByte CountRead/WriteData TypeTransmission Data Description40001Pulse Frequency Of Flow4W/RFLOATUnit Hz40003Number Of Pulses4RUSHORTL/M, Unit Configurable.40005Reservations4RFLOAT09H 10H: Integer Part, Assuming Data A.40007Prompt Flow4RFLOAT11H 12H: Fractional Part, Assuming Data B40009Integer Portion Of Cumulative Flow4RUSHORTAnd Cumulative Flow = A + B.400011Fractional Part Of Cumulative Flow4RFLOAT09H 10H: Integer Part, Assuming Data A.R11H 12H: Fractional Part, Assuming Data B. Cumulative Flow = A +PULSE FREQUENCY FOR READING THE FLOW RATEAs Shown In Table 1.1, The Pulse Frequency Of The Read Flow Corresponds To Addresses 40001 And 40002, I.E., 00H And 01H Registers, And The Corresponding Commands Are As Follows: 01 03 00 00 00 00 02 C4 0BSlave AddressFunctionAddressNumber Of RegistersCRCYour (Honorific)Lower (One'S Head)Your (Honorific)Your (Honorific)Lower (One'S Head)Your (Honorific)1Code0002C40BThe Flow Meter Response Is As Follows:01 03 04 3A AE 41 72 27 7FSlave AddressFunction CodeByte CountRegister 0X01 DataCRCYour (Honorific)Lower (One'S Head)Your (Honorific)Lower (One'S Head)Lower (One'S Head)Your (Honorific)133AAE4172277FREAD INSTANTANEOUS FLOW RATEAs Shown In Table 1.1, The Addresses Corresponding To Reading The Instantaneous Flow Rate Are 40007 And 40008, I.E., 06H And 07H Registers, And The Corresponding Commands Are As Follows: 01 03 00 06 00 02 24 0ASlave AddressFunction CodeAddressNumber Of RegistersCRCYour (Honorific)Lower (One'S Head)Your (Honorific)Your (Honorific)Lower (One'S Head)Your (Honorific)130602240ADetailed PhotosCOMPACT AND LIGHTWEIGHT DESIGN ROBUST CONSTRUCTIONThe simple, in-line design results in a smaller and lighter meter, making it easier to install and support, especially in larger pipe sizes.Made from corrosion-resistant, high-quality materials to ensure long-lasting operation even in harsh environments.COMPACT AND SPACE-SAVING DESIGNEASY MAINTENANCE AND CALIBRATIONSmall footprint allows integration into systems with limited space without compromising performance.Designed for simple periodic calibration and minimal maintenance, reducing downtime and service costs.FAQQ1: Are you a factory or a trader?A: We are a manufacturer integrating industry and trade. Welcome to visit our company. Q2: Can I add my LOGO to the product?A: We support on-demand customization, including LOGO customization, color customization, appearance size customization, etc. Q3: What payment methods do you support?A: We support T/T, Western Union, PayPal, cash, etc. The details can be negotiated. Q4: What are your modes of transportation?A: We usually choose the appropriate mode of transportation (sea, air, land) according to the conditions of the goods, or we can choose the mode of transportation according to your requirements. Q5: How can I get an accurate quotation?A: You can first send your specific demand information and product pictures, and we will customize a solution for you according to your needs and inform you of the specific price.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...