IPDB › China Industry › Instruments & Meters
China, Chinese Honeywell SPXCDXSO1SS XCD Oxygen O2 Sensor 25.0% Vol Sensor Cartridge1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
SensorGas SensorHoneywell SPXCDXSO1SSXCD Oxygen O2 Sensor
BNSENS Co., Ltd.
Preview:
Product Description The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and Oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. This enables one-man, non-intrusive operation and reduces routine maintenance time and costs.The Sensepoint XCD comprises a gas detector transmitter and a choice of sensors for detecting flammable gas, toxic gas and oxygen. The construction of Sensepoint XCD allows it to be used in hazardous area locations; it may also be used in other areas not classified as hazardous. The transmitter features a display and three programmable relays for controlling external equipment e.g. alarms, sirens, valves or switches. The transmitter provides an industry standard 3-wire, 4-20 mA source or sink output for connection to a dedicated gas detection control system or PLC. Calibration and maintenance are carried out using a Magnetic Wand, this allows a single user to undertake routine maintenance without needing to access internal components. Sensepoint XCD comprises of the main parts as shown below.Installing the sensorTo install the Sensepoint XCD Sensor Cartridge to the transmitter Sensor Socket: 1. Remove the weather protection (if fitted) from the sensor. 2. Use a 1.5 mm Allen key (hexagonal wrench-included) to loosen the Locking Grub Screw on the Sensor Retainer. 3. Unscrew and remove the Sensor Retainer. 4. Remove the XCD Sensor Cartridge from its packaging and plug it into the XCD Sensor Socket, taking care to align the sensor pins with the connector. 5. Refit the Sensor Retainer and tighten the Locking Grub Screw. 6. Refit the weather protection (as required) to the Sensepoint XCD sensor.Sensor replacement The Flammable Catalytic and Toxic ECC sensor cartridges that are used with the Sensepoint XCD Sensor Socket have no serviceable parts. When they have reached the end of their operational life, simply replace the sensor cartridge. To replace the Sensepoint XCD plug-in sensor cartridge use the following procedure: 1. Important: Remove the Power from the Sensepoint XCD Transmitter 2. Remove the Weather Protection or other accessories from the sensor socket thread 3. Loosen the Locking Grub Screw and unscrew the Sensor Retainer 4. Carefully pull the old Sensor from the sensor socket without twisting 5. Fit the new Sensor in its place 6. Calibrate sensorOrdering informationPart numberDescriptionSensepoint XCD transmitter and sensor KIT (ATEX/IECEx/AP*, LM25 and M20 Entry)SPXCDALMFXATEX/IECEx/AP* Methane CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 EntrySPXCDALMRXATEX/IECEx/AP* Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 EntrySPXCDALMPXATEX/IECEx/AP* Propane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 EntrySPXCDALMO1ATEX/IECEx/AP* Oxygen 25.0% v/v with LM25, M20 EntrySPXCDALMHXATEX/IECEx/AP* Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, M20 EntrySPXCDALMCXATEX/IECEx/AP* Carbon Monoxide 0-500ppm (100 to 1000ppm, 100ppm) with LM25, M20 EntrySPXCDALMG1ATEX/IECEx/AP* Hydrogen 0-1000ppm with LM25, M20 EntrySPXCDALNNXATEX/IECEx/AP* Nitrogen Dioxide 0-50ppm with Aluminum alloy, M20 EntrySPXCDALMB1ATEX/IECEx/AP* approved Carbon Dioxide IR 0-2.00% v/v with LM25, M20 EntrySPXCDALMB2ATEX/IECEx/AP* approved Carbon Dioxide IR 0-5.00% v/v with LM25, M20 EntrySensepoint XCD transmitter and sensor KIT (ATEX/IECEx/AP*, 316SS and M20 Entry)SPXCDASMFXATEX/IECEx/AP* approved Methane CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 EntrySPXCDASMRXATEX/IECEx/AP* approved Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 EntrySPXCDASMPXATEX/IECEx/AP* approved Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 EntrySPXCDASMO1ATEX/IECEx/AP* approved Oxygen 25.0% v/v with 316SS, M20 EntrySPXCDASMHXATEX/IECEx/AP* approved Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, M20 EntrySPXCDASMCXATEX/IECEx/AP* approved Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, M20 EntrySPXCDASMG1ATEX/IECEx/AP* approved Hydrogen 0-1000ppm with 316SS, M20 EntrySPXCDASNNXATEX/IECEX/ AP* approved Nitrogen Dioxide 0-50ppm with SS316, M20 EntrySPXCDASMB1ATEX/IECEx/AP* approved Carbon Dioxide IR 0-2.00% v/v with 316SS, M20 EntrySPXCDASMB2ATEX/IECEx/AP* approved Carbon Dioxide IR 0-5.00% v/v with 316SS, M20 EntrySensepoint XCD transmitter and sensor KIT (UL, LM25 and 3/4' NPT Entry)SPXCDULNFXUL/cUL approved Methane CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4, NPT EntrySPXCDULNRXUL/cUL approved Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4, NPT EntrySPXCDULNPXUL/cUL approved Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4, NPT EntrySPXCDULNO1UL/cUL approved Oxygen 25.0% v/v with LM25, 3/4, NPT EntrySPXCDULNHXUL/cUL approved Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, 3/4, NPT EntrySPXCDULNCXUL/cUL approved Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with LM25, 3/4, NPT EntrySPXCDULNG1UL/cUL approved Hydrogen 0-1000ppm with LM25, 3/4, NPT EntrySPXCDULNNXUL approved SP XCD Nitrogen Dioxide 0-50ppm with LM25, 3/4, NPT EntrySPXCDULNB1UL/cUL approved Carbon Dioxide IR 0-2.00% v/v with LM25, 3/4, NPT EntrySPXCDULNB2UL/cUL approved Carbon Dioxide IR 0-5.00% v/v with LM25, 3/4, NPT EntrySensepoint XCD transmitter and sensor KIT (UL, 316SS and 3/4, NPT Entry)SPXCDUSNFXUL/cUL approved Methane CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4, NPT EntrySPXCDUSNRXUL/cUL approved Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4, NPT EntrySPXCDUSNPXUL/cUL approved Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4, NPT EntrySPXCDUSNO1UL/cUL approved Oxygen 25.0% v/v with 316SS, 3/4, NPT EntrySPXCDUSNHXUL/cUL approved Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, 3/4, NPT EntrySPXCDUSNCXUL/cUL approved Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, 3/4, NPT EntrySPXCDUSNG1UL/cUL approved Hydrogen 0-1000ppm with 316SS, 3/4, NPT EntrySPXCDUSNNXUL approved SP XCD Nitrogen Dioxide 0-50ppm with SS316, 3/4, NPT EntrySPXCDUSNB1UL/cUL approved Carbon Dioxide IR 0-2.00% v/v with 316SS, 3/4, NPT EntrySPXCDUSNB2UL/cUL approved Carbon Dioxide IR 0-5.00% v/v with 316SS, 3/4, NPT EntrySensepoint XCD transmitter and sensor KIT (ATEX/IECEx/AP*, LM25 and M20 Entry with Modbus)SPXCDALMFXMATEX/IECEx/AP* Methane CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 Entry, with ModbusSPXCDALMRXMATEX/IECEx/AP* Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 Entry, with ModbusSPXCDALMPXMATEX/IECEx/AP* Propane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 Entry, with ModbusSPXCDALMO1MATEX/IECEx/AP* Oxygen 25.0% v/v with LM25, M20 Entry, with ModbusSPXCDALMHXMATEX/IECEx/AP* Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, M20 Entry, with ModbusSPXCDALMCXMATEX/IECEx/AP* Carbon Monoxide 0-500ppm (100 to 1000ppm, 100ppm) with LM25, M20 Entry, with ModbusSPXCDALMG1MATEX/IECEx/AP* Hydrogen 0-1000ppm with LM25, M20 Entry, with ModbusSPXCDALNNXMATEX/IECEX /AP approved Nitrogen Dioxide 0-50ppm with LM25, M20 Entry, With ModbusSPXCDALMB1MATEX/IECEx/AP* approved Carbon Dioxide IR 0-2.00% v/v with LM25, M20 Entry, with ModbusSPXCDALMB2MATEX/IECEx/AP* approved Carbon Dioxide IR 0-5.00% v/v with LM25, M20 Entry, with ModbusSensepoint XCD transmitter and sensor KIT (ATEX/IECEx/AP*, 316SS and M20 Entry with Modbus)SPXCDASMFXMATEX/IECEx/AP* approved Methane CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with ModbusSPXCDASMRXMATEX/IECEx/AP* approved Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with ModbusSPXCDASMPXMATEX/IECEx/AP* approved Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with ModbusSPXCDASMO1MATEX/IECEx/AP* approved Oxygen 25.0% v/v with 316SS, M20 Entry, with ModbusSPXCDASMHXMATEX/IECEx/AP* approved Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, M20 Entry, with ModbusSPXCDASMCXMATEX/IECEx/AP* approved Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, M20 Entry, with ModbusSPXCDASMG1MATEX/IECEx/AP* approved Hydrogen 0-1000ppm with 316SS, M20 Entry, with ModbusSPXCDASNNXMATEX/IECEX /AP approved Nitrogen Dioxide 0-50ppm with SS316, M20 Entry, With ModbusSPXCDASMB1MATEX/IECEx/AP* approved Carbon Dioxide IR 0-2.00% v/v with 316SS, M20 Entry, with ModbusSPXCDASMB2MATEX/IECEx/AP* approved Carbon Dioxide IR 0-5.00% v/v with 316SS, M20 Entry, with ModbusUL APPROVAL (Epoxy Coated Aluminum Alloy, LM25, With Modbus)SPXCDULNFXMUL/cUL approved Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, 3/4, NPT Entry, with ModbusSPXCDULNRXMUL/cUL approved Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, 3/4, NPT Entry, with ModbusSPXCDULNPXMUL/cUL approved Propane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, 3/4, NPT Entry, with ModbusSPXCDULNO1MUL/cUL approved Oxygen 25.0% v/v with LM25, 3/4, NPT Entry, with ModbusSPXCDULNHXMUL/cUL approved Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, 3/4, NPT Entry, with ModbusSPXCDULNCXMUL/cUL approved Carbon Monoxide 0-500ppm (100 to 1000ppm, 100ppm) with LM25, 3/4, NPT Entry, with ModbusSPXCDULNG1MUL/cUL approved Hydrogen 0-1000ppm with LM25, 3/4, NPT Entry, with ModbusSPXCDULNNXMUL/cUL approved Nitrogen Dioxide 0-50ppm with LM25, 3/4, NPT Entry, with ModbusSPXCDULNB1MUL/cUL approved Carbon Dioxide IR 0-2% v/v with LM25, 3/4, NPT Entry, with ModbusSPXCDULNB2MUL/cUL approved Carbon Dioxide IR 0-5% v/v with LM25, 3/4, NPT Entry, with ModbusUL APPROVAL (Epoxy Coated Stainless Steel, SS316, With Modbus)SPXCDUSNFXMUL/cUL approved Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with SS316, 3/4, NPT Entry, with ModbusSPXCDUSNRXMUL/cUL approved Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with SS316, 3/4, NPT Entry, with ModbusSPXCDUSNPXMUL/cUL approved Propane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with SS316, 3/4, NPT Entry, with ModbusSPXCDUSNO1MUL/cUL approved Oxygen 25.0% v/v with SS316, 3/4, NPT Entry, with ModbusSPXCDUSNHXMUL/cUL approved Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with SS316, 3/4, NPT Entry, with ModbusSPXCDUSNCXMUL/cUL approved Carbon Monoxide 0-500ppm (100 to 1000ppm, 100ppm) with SS316, 3/4, NPT Entry, with ModbusSPXCDUSNG1MUL/cUL approved Hydrogen 0-1000ppm with SS316, 3/4, NPT Entry, with ModbusSPXCDUSNNXMUL/cUL approved Nitrogen Dioxide 0-50ppm with SS316, 3/4, NPT Entry, with ModbusSPXCDUSNB1MUL/cUL approved Carbon Dioxide IR 0-2% v/v with SS316, 3/4, NPT Entry, with ModbusSPXCDUSNB2MUL/cUL approved Carbon Dioxide IR 0-5% v/v with SS316, 3/4, NPT Entry, with ModbusReplacement sensor CartridgeSPXCDXSFXSSMethane CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL)SPXCDXSRXSSMethane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL)SPXCDXSPXSSPropane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL)SPXCDXSO1SSOxygen 25.0% v/v onlySPXCDXSHXSSHydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm)SPXCDXSCXSSCarbon Monoxide 0-500ppm (100 to 1000ppm, 100ppm)SPXCDXSG1SSHydrogen 0-1000ppm onlySPXCDXSNXSSNitrogen Dioxide 0-10ppm (10.0 to 50.0ppm)SPXCDXSB1SSCarbon Dioxide IR 0-2.00% v/v onlySPXCDXSB2SSCarbon Dioxide IR 0-5.00% v/v onlyAccessoriesS3KCALCalibration capSPXCDCCCollecting cone for use with lighter than air gasesSPXCDDMKDuct mounting kitSPXCDMTBRPipe Mounting bracket (including fixings and hex wrench set)SPXCDSDPSunshade / Deluge ProtectionSPXCDHMANENHard Copy Manual in English languageSPXCDHMANCNHard Copy Manual in Chinese languageSPXCDHMANKRHard Copy Manual in Korean languageSparesSPXCDDMT12Replacement display module (O2 & Toxic)SPXCDDMF12Replacement display module (FL & IR)SPXCDTMO12Replacement terminal module (O2)SPXCDTMT12Replacement terminal module (Toxic)SPXCDTMF12Replacement terminal module (FL & IR)SPXCDMBUSReplacement Modbus ModuleSPXCDSERVKService Kit containing all o-rings, terminal module and locking screwsSPXCDTOOLKFactory toolkit containing magnetic wand and hex wrenches for locking and earth screwsSPXCDTMKTerminal block setSPXCDNPTP3/4, NPT PlugSPXCDM20PM20 PlugSPXCDMANCDInstruction manual CD-ROMSPXCDNADP3/4, NPT to M20 AdaptorSPXCDWPWeather ProtectionSPXCDSRLSSensor Retainer with locking screwSPXCDEBSEarth Bracket and ScrewsSpecial Flammable Gas CalibrationSPXCDSFGC1Special Flammable Gas Calibration, 0-100%LEL, 1*SPXCDSFGC2Special Flammable Gas Calibration, 0-100%LEL, 2*SPXCDSFGC3Special Flammable Gas Calibration, 0-100%LEL, 3*SPXCDSFGC4Special Flammable Gas Calibration, 0-100%LEL, 4*SPXCDSFGC5Special Flammable Gas Calibration, 0-100%LEL, 5*SPXCDSFGC7Special Flammable Gas Calibration, 0-100%LEL, 7*SPXCDSFGC8Special Flammable Gas Calibration, 0-100%LEL, 8*Note: If no Special Flammable Gas Calibration part no. is included on PO, a Methane (6* calibration will be supplied) https://bnsens.en.made-in-china.com/product/JtfRyruOvqkm/China-Honeywell-Midas-Gas-Detector-MIDAS-K-HCL.html BNSENS (Nanjing) Sensor Technology Co., Ltd. is located in Nanjing, China. It is a high-tech enterprise specializing in the development, manufacturing and trade of sensor products. The company has brought together a group of outstanding technical experts in various fields such as automation, electronics, machinery and computers. All employees of the company have college degrees or above. It adopts the world-class management and operation model and 6 sigma quality system. At present, the company's main products are pressure, liquid level, flow, current, switches, etc. The company's users are all over the country, and some products have been exported to Japan, South Korea and Southeast Asia.Since its inception, the company has been based on the technical accumulation and management standards of American sensor giants. It is composed of senior engineers and managers who have served in multinational companies for many years, and has rapidly developed various pressure sensors, transmitters, liquid level, flow meters, pressure switches, digital meters, current sensors, proximity switches and other products. After years of unremitting efforts, it has become one of the leading suppliers in the domestic automation industry. Our pressure transmitters can achieve an accuracy of more than 3/10, 000. The products have been widely used in oil, natural gas, electricity, chemical industry, metallurgy, building materials, food, light industry, environmental protection, aerospace, tap water, municipal and other industries.It is a sensor science and technology innovation company that masters the core technology of MEMS chips. The company has a research and development center in Minnesota, USA. The leader is Dr. Pan Hanjin, a famous scientist in the sensor industry. Dr. Pan Hanjin has been deeply involved in the sensor industry for more than 20 years and is an expert in the sensor industry.The company has a number of ASIC chips independently developed, which are widely used in industrial, automotive, home appliance and other markets.BNSENS (Nanjing) Sensing Technology Co., Ltd. is a strategic partner of Honeywell in China. The two parties proposed a plan of East serving East and jointly developed several sensors specifically for the Chinese market. These sensors will be widely used in intelligent manufacturing, Internet of Things, artificial intelligence, and smart home fields. These sensors include: Magnetic sensors, temperature sensors, humidity sensors, force sensors, fire water pressure sensors, equipment vibration sensors, human body status monitoring sensors, motion sensors, etc.History of BNSENS Company:BNSENS is a company focusing on sensors, instruments, and electronic components. We are a young company, founded in 1999, just 25 years old, and we are still growing.1999: The company's first pressure sensor was launched, mainly for the petroleum and petrochemical industries.2002: The company expanded its product line and launched temperature sensors2005: Started producing high-precision pressure sensors for the test and measurement market2006: Became an official authorized agent of Honeywell2009: Introduced the Six Sigma management system, and the product qualification rate was greatly improved2010: Became a supplier of Emerson2011: We started selling SICK sensors2014: Introduced the sensor production line from Germany, developed more industrial control sensors, and cooperated with TSMC2015: Cooperated with Siemens in Vietnam2017: The factory moved to Nanjing High-tech Zone2019: Became a national high-tech enterprise in China2023: We started selling products from Infineon and RohmBNSENS, The Future Starts Here.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...