IPDB › China Industry › Instruments & Meters
China, Chinese Siemens 7ME5865-2FD33-0AA0 Electromagnetic Liquid Flow Measurement Device1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Meter for Liquid GasOther Meters for Liquid GasLiquid Flow Measurement DeviceElectromagnetic Flowmeter
Beijing Zhongping Technology Co., Ltd.
Preview:
Product Description Title:Siemens 7ME5865-2FD33-0AA0 MAG 6000 Electromagnetic Flowmeter DN100The Siemens 7ME5865-2FD33-0AA0 is a MAG 6000 electromagnetic flowmeter designed for precise flow measurement of conductive liquids.With a DN100(4-inch)nominal diameter and IP67 protection,this compact flowmeter delivers accurate measurement with minimal pressure drop.The device features robust construction suitable for water,wastewater,and various industrial process applications requiring reliable flow monitoring.Product ParametersParameter Name Parameter ValueProduct Designation MAG 6000 FlowmeterArticle Number 7ME5865-2FD33-0AA0Nominal Diameter DN100(4 inch)Measurement Range 0.1-10 m/sAccuracy±0.3%of measured valuePressure Rating PN16Process Temperature-25°C to+120°CProtection Class IP67Electrode Material Stainless Steel 1.4435Lining Material PTFAOutput Signals 4-20 mA,PulseProduct FeaturesThis electromagnetic flowmeter utilizes Faraday's law of induction for precise flow measurement independent of fluid density,viscosity,and temperature.The compact SITRANS F C sensor design ensures minimal space requirements.Integrated empty pipe detection prevents false measurements.The robust housing provides excellent EMC immunity and environmental protection.Advanced signal processing ensures stable measurement even under challenging conditions.The device features bidirectional flow measurement capability.Automatic electrode cleaning function maintains long-term accuracy.Modular design allows easy maintenance and component replacement.AdvantagesHigh measurement accuracy ensures reliable process control and billing applications.Minimal pressure drop reduces energy consumption in pumping systems.Robust construction guarantees long-term stability in harsh environments.Wide measurement range accommodates varying flow conditions.Bidirectional measurement eliminates need for specific installation orientation.Comprehensive diagnostics enable predictive maintenance and reduce downtime.Application ScenariosThis flowmeter is ideal for drinking water distribution and monitoring systems.It serves wastewater treatment plants for inflow and sludge measurement.The device operates in chemical processing for corrosive liquid measurement.Other applications include pharmaceutical production for batch process control.It is used in food and beverage industry for ingredient flow monitoring.The flowmeter serves HVAC systems for chilled and hot water circuits.Usage InstructionsInstall the flowmeter in vertical or horizontal pipelines ensuring full pipe conditions.Maintain straight pipe runs of 5D upstream and 3D downstream for optimal accuracy.Ground the pipeline properly according to installation guidelines.Configure parameters such as measuring unit,current output,and pulse value.Perform zero point calibration under no-flow conditions.Verify proper operation through simulated flow conditions.PrecautionsEnsure the measured liquid has minimum conductivity of 5μS/cm.Avoid installation in locations with strong electromagnetic interference.Protect from direct sunlight and extreme weather conditions.Verify chemical compatibility of wetted materials with process media.Use appropriate lifting equipment during installation due to weight.Follow safety procedures when working with pressurized systems.Frequently Asked QuestionsWhat is the minimum fluid conductivity required for accurate measurement?The MAG 6000 requires a minimum fluid conductivity of 5μS/cm for reliable operation.This relatively low threshold makes it suitable for most water applications,including deionized water in many cases.The measurement principle relies on Faraday's law,where the induced voltage is proportional to the flow velocity and magnetic field strength.For fluids with conductivities near the minimum threshold,ensure optimal grounding conditions and consider using the built-in signal amplification features.The flowmeter automatically detects and compensates for conductivity variations within the operating range.For applications with fluctuating conductivity,the advanced signal processing maintains measurement stability.If conductivity falls below the minimum threshold,the device provides clear diagnostic warnings to alert operators of potential measurement inaccuracies.How does the empty pipe detection function work?The empty pipe detection uses intelligent electrode monitoring to determine when the pipe is not completely filled.The system continuously measures the electrical characteristics between electrodes and detects significant changes indicating air or gas presence.When an empty pipe condition is detected,the flowmeter can be configured to hold the last value,output zero,or trigger an alarm based on application requirements.This feature prevents false flow readings during partial fill conditions,ensuring measurement integrity.The detection sensitivity can be adjusted to match specific process conditions.The empty pipe status is available as a discrete output and can be integrated into control system logic for appropriate response actions.What maintenance procedures are required for long-term accuracy?Regular maintenance includes visual inspection for physical damage or coating buildup on electrodes.Verify zero point calibration quarterly under no-flow conditions.Check electrode resistance annually using diagnostic functions-values should typically be between 1 kΩand 50 MΩ.Inspect liner condition for wear or damage during planned shutdowns.The built-in electrode cleaning function can be activated manually or scheduled automatically to maintain signal quality.For applications with heavy coating tendencies,consider periodic mechanical cleaning.Document all maintenance activities and performance verification for trend analysis and predictive maintenance planning.Can this flowmeter measure bidirectional flow?Yes,the 7ME5865-2FD33-0AA0 supports bidirectional flow measurement without additional hardware.The device automatically detects flow direction and provides signed measurement values.Directional identification is available through the current output(below 4mA or above 20mA)or as a discrete signal.The bidirectional capability is particularly valuable for applications involving backflow,storage tank filling/emptying,or complex piping networks.Configuration allows separate parameterization for forward and reverse flow measurements,including individual scaling of current outputs and pulse values.This flexibility ensures optimal performance in applications where flow direction may change periodically or unexpectedly.What communication options are available?The standard configuration includes 4-20 mA analog output and pulse/frequency output for totalization.Additionally,the device supports HART communication for advanced parameterization and diagnostics.For projects requiring fieldbus integration,Siemens offers separate transmitter versions with PROFIBUS PA or Foundation Fieldbus protocols.The HART interface enables remote configuration,calibration,and diagnostic access using standard HART communicators or asset management systems.All measured values,diagnostic parameters,and device status information are accessible through the digital communication interface.How does temperature affect measurement accuracy?The flowmeter maintains specified accuracy across the entire operating temperature range of-25°C to+120°C through integrated temperature compensation.The electronics automatically compensate for temperature effects on both the measurement system and reference circuits.For extreme temperature applications,ensure the process temperature remains within the specified limits for the selected liner material.In applications with rapid temperature changes,the advanced signal processing algorithms minimize measurement disturbances.The device provides temperature monitoring as a diagnostic parameter,enabling operators to correlate potential measurement variations with process temperature changes.What are the installation requirements for optimal performance?Installation requires straight pipe runs of 5 times the nominal diameter upstream and 3 times downstream from the flowmeter.Ensure the pipeline remains completely filled during operation-vertical upward flow installations are preferred.Proper grounding is critical;use the provided grounding rings or ensure metal pipe contact in conductive piping systems.Avoid installation near pumps,control valves,or other flow-disturbing elements.Maintain accessibility for maintenance and inspection.For outdoor installations,consider sun protection to prevent excessive temperature buildup.Follow all local electrical and safety codes during installation.What diagnostic functions are available?Comprehensive diagnostics include electrode contamination monitoring,liner condition assessment,empty pipe detection,and process noise evaluation.The device continuously monitors signal quality and provides early warnings of developing issues.Additional diagnostics cover hardware integrity,memory status,and configuration consistency.Diagnostic messages are available locally through the display and remotely via communication interfaces.The flowmeter supports NAMUR NE107 recommendations for standardized diagnostic alerts,ensuring clear understanding of device status across different asset management systems.How is the flowmeter calibrated and verified?Initial calibration is performed at the factory using traceable standards,providing documented calibration certificates.Field verification can be performed using the built-in simulation function or through zero point calibration under no-flow conditions.For critical applications,on-site calibration using portable flow standards is recommended annually.The device maintains calibration stability through robust signal processing and temperature compensation.If required,the calibration can be adjusted using known reference values.All calibration data is stored in non-volatile memory with access protection to prevent unauthorized modification.What is the expected service life in typical applications?The expected service life typically exceeds 10 years in standard water applications with proper maintenance.The non-moving parts design and robust construction contribute to long-term reliability.Service life depends on operating conditions including fluid characteristics,temperature cycles,and environmental factors.Electrodes and liners are the primary wear components,with service life varying based on abrasion and chemical exposure.Regular monitoring of diagnostic parameters helps predict end-of-life for these components.The modular design allows replacement of wear parts without replacing the entire flowmeter,extending the overall service life economically.Beijing Zhongping Technology Co., Ltd. is a leading provider of industrial automation solutions, intelligent robotics, and advanced system integration services. With decades of expertise, the company has established long-term strategic partnerships with global industry leaders such as Siemens, ABB, Schneider Electric, KUKA, Yaskawa, and FANUC, leveraging their cutting-edge technologies to deliver innovative, tailored solutions across diverse sectors.Specializing in technical support, product distribution, and end-to-end engineering services-including system design, installation, commissioning, and maintenance-Beijing Zhongping Technology ensures seamless operational efficiency for clients in industries spanning automotive manufacturing, battery production, aerospace, oil and gas, chemical processing, food and pharmaceuticals, logistics, metallurgy, and heavy machinery. By harnessing its robust global supply chain network and a highly skilled technical team, the company guarantees precision-driven resource allocation, rapid response capabilities, and cost-effective procurement strategies. These capabilities empower clients to streamline operations, reduce downtime, and enhance competitive advantage in dynamic markets. Committed to excellence, Beijing Zhongping Technology remains dedicated to advancing industrial innovation while fostering sustainable growth and value creation for enterprises worldwide.Q1: What is the core business scope of Beijing Zhongping Technology Co., Ltd.?The company's business scope primarily covers comprehensive industrial robot supply chain services, industrial automation technologies and technical services, digital smart factory solutions, and hydraulic intelligent control products and services.Q2: Which brands does the company collaborate with?The main cooperative brands of the company are SIEMENS,ABB,Schneider,DELTA,WEINVIEW,MCGS,ADVANTECH,OMRON,Simphoenix,RITTAL,MOXA,ESTUN, RKC, YASKAWA, HIKVISION, FANUC, MITSUBISHI ELECTRIC, KUKA, Fuji Electric, SICK, Walvoil, CASAPPA, EATON, Bosch Rexroth Group, Parker etc.Q3: What are our competitive advantages compared to other suppliers?With our robust supply chain capabilities and global presence, we deliver faster, more efficient services. We strive to offer the best possible prices to demonstrate our sincerity and value.Q4: How long does delivery take? What about shipping costs?Delivery timelines and shipping costs depend on the specific model(s) and quantity you require. Please share your current needs with us for precise details.Q5: Can't find the model you need?We showcase only a selection of models here. If you cannot find your desired model, contact us directly for further assistance.Q6: How to contact Beijing Zhongping Technology Co., Ltd.?Beijing Zhongping Technology Co., Ltd.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...