IPDB › China Industry › Instruments & Meters
China, Chinese 100mv/Ka Rogowski Coil Current Transformer Flexible Cts Current Clamp AC Current Probe1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
SensorCurrent SensorRogowski CoilCurrent Probe
ROGOWSKI TECHNOLOGY (SHANGHAI) CO., LTD.
Preview:
Product Description NRC ?8 Flexible Rogowski coil fixed by cable tiesHigh linearity from 1A to 100kAWide dynamic rangeVery useful with large size or awkward shaped conductors or in places with limited accessNo danger from open-circuited secondaryNot damaged by large overloadsNon-intrusive, no power drawn from the mainMeasurement uniformity at any position of the conductor inside the coilExcellent degree of rejection to the external current conductor FeatureNRC is a flexible current transducer based on Rogowski principle, particularly suitable for measurement in combination with portable devices. NRC coils are available in different sizes and can be supplied according to customer's design, therefore they can be used in all those applications, in which traditional transducers are not fitting due to its size and/or weight.Due to its specific features, flexible Rogowski coil is an extremely comfortable solution for current measurement and can be used in a number of cases where traditional current transducer is not the adequate solution.NRC coil is provided with a shield against the influence of external magnetic fields; therefore, it grants a stable measurement from low currents to hundreds of kA. The Rogowski coils must be connected to an electronic integrator for 90° phase shift compensation and frequency equalization. Our DIN-RAIL and panel meters can interface Rogowski coils directly without the need of the external integrators. This is an advantage because there are no external boxes or any power supply with consequent ease of use. The particular features of the Rogowski coils combined with the extremely flexible input programming of our portable meters, allow to carry out measurement by all applications. Advantage? Calibrated to 0.5% ? 8mm section easy to install ? Easy to fixed on bus-bar and cable by cable ties? Lower zero drift down to 0.1mVRelated ProductsS1 D1 S10 SW DA01 DA05 ME631 ME435 ME440 Applications? Measuring devices, lab instrumentation ? Power monitoring & control systems ? Harmonics and transients monitoring ? Very high current monitoring What is a Rogowski coil?Rogowski coils have been used for the detection and measurement of electric currents for decades. They are based on a simple principle: an "air-cored" coil is placed around the conductor in a toroidal fashion and the magnetic field produced by the current induces a voltage in the coil. The voltage output is proportional to the rate of change of current. This voltage is integrated, thus producing an output proportional to the current.By using precision winding techniques, especially developed for the purpose, the coils are manufactured so that their output is not influenced by the position of the conductor within the toroid, and to reject interference from external magnetic fields caused, for example, from nearby conductors.Basically, a Rogowski coil current measuring system consists of a combination of a coil and conditioning electronics.Rogowski coil current transducers are used for the AC measurement.They can be used in similar circumstances to current transformers but for many applications they have considerable advantages:? Wide dynamic range.? High linearity.? Very useful with large size or awkward shaped conductors or in places with limited access. Thanks to the structure without hard core, the coil can be easily manufactured according to the application or to the available space.? Unlike traditional current transducers, there is no danger from open-circuited secondaries.? They cannot be damaged by large overloads.? They are non-intrusive. They draw no power from the main circuit carrying the current to be measured.? They are also light weighted and in some applications are light enough to be suspended on the conductor being measured.The transducer does not measure direct currents , but unlike a current transformer, it can carry out accurate measurements of AC component even if there is a large superimposed DC component, since there is no iron core causing saturation. This feature is particularly useful for measuring ripple currents for example in battery charging systems.SpecificationMODELNRC-100NRC-150NRC-200Coil length395mm525mm665mmWindow size100mm150mm200mmReference Rated current1000A3000A6000ACoil Resistance 260 (+/-10) Ω320 (+/-10) Ω390 (+/-10) ΩWeightApprox. 140gApprox. 150gApprox. 170gRatioCalibrated85mV/kA@50Hz102mV/kA@60Hz50mV/kA@50Hz60mV/kA@60HzUncalibrated110mV/kA@50Hz132mV/kA@60HzRead AccuracyCalibrated <0.5% (central position, 25oC)Uncalibrated < 5% tolerance (central position, 25oC)Maximum current measurable 100kACoil Section8mmLead length2meterTemperatureUncalibrated 200ppm/CCalibrated 300ppm/CPosition Error±1% maximumOutput on 0A(zero drift)≤0.05mVPhase error≤0.5°Linearity±0.2% of readingBandwidth1Hz to 100kHz(-3dB)Operating temperature-30oC to 80oCStorage temperature-40oC to 90oCFor other requirements, please contact us for customization.Position sensitivityConductor PositionTypical Error (%)Adjacent to the center of coil<0.5%Adjacent to the inside of coil<1%Materials Coil & cableThermoplastic rubberflame retardant UL 94 V-0 ratedCouplingsPC, ABS UL 94 V-0 ratedColor(coil)Orange, Yellow, Red, Green, BlueShielded100% coil, 100% output cableSafety Certifications CE markedComplies with LVD EN 61010-1:2010EMC EN 61326-1:2013IP67 Voltage insulationCoil: 2000VSignal cable:1000VSafety1000V CATIII ,600V CATIV Dimension's tolerance:A,B,C,F:±5mm, D:±0.2mm,E:±10mmDimensions(mm)NRC-100NRC-150NRC-200Windows size A135165210Windows size B100150200Coil O.D.151181226Coil section8Lead Cable Total Length2000Coil length395525665More Special Rogowski coil+Integrator for fault indicatorRogowski coil NZ special for high temperature electric furnaceRogowski Coil Sensor for Lightning currentSafety and warning notesIn order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions, please read these instructions thoroughly! Safe operation can only be guaranteed if the transducer is used for the purpose, it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associated datasheet under Rogowski website.Caution! Risk of dangerIgnoring the warnings can lead to serious injury and/or cause damage!The electric measuring transducer may only be installed and put into operation by qualified personnel that have received an appropriate training, The corresponding national regulations shall be observed during installation and operation of the transducer and any electrical conductor. The transducer shall be used in electric/electronic equipment the respect to applicable standards and safety requirements and in accordance with all the related systems and components manufacturers' operating instructions.Caution! Risk of electrical shockWhen operating the transducer, certain parts of the module may carry hazardous live voltage (e.g., Primary conductor). The user shall ensure to take all measures necessary to protect against electrical shock. The transducer is a build-in device containing conducting parts that shall not be accessible after installation. A protective enclosure or additional insulation barrier may be necessary. Installation and maintenance shall be done with the main power supply disconnected except if there are no hazardous live parts in or in close proximity to the system and if the applicable national regulations are fully observed.Safe and trouble-free operation of this transducer can only be guaranteed if transport, storage and installation are carried out correctly and operation and maintenance are carried out with care.Caution! Risk of electrical shockDo not apply around or remove from uninsulated hazardous live conductors which may result in electric shock, electric burn or arc flash.WARING!Do not stress the coil by applying any kind of mechanical force (transport, storage pressure, tight bending.) which will dramatically degrade the device's accuracy.MEATROL Rogowski coil Model No. Definition:DescriptionConnector modelWindow size BSignal cable length ERatioModel No. Calibrated(mV/kA@50Hz)Uncalibrated(mV/kA@50Hz)? 6 Mini typewith fixing ribbon tiesMRC162m50(60mV/kA@60Hz)60(72mV/kA@60Hz)MRC-16-2m-5024MRC-24-2m-5036MRC-36-2m-50?8 Rotate bayonet typeEasy installationwith fixing ribbon tiesNRC1002m85105NRC-100-2m-8515085NRC-150-2m-8520050NRC-200-2m-50?12 High Voltage36kVD-SRC502m________60(72mV/kA@60Hz)D-SRC-50-2m-60100D-SRC-100-2m-60150D-SRC-150-2m-60?12 High SensitivitySRC502m333360SRC-50-2m-333100SRC-100-2m-333150SRC-150-2m-333? 6 precision typeTRC162m5060TRC-16-2m-5024TRC-24-2m-5036TRC-36-2m-50?8 Snap-in typeEasy installationZRC502m100 / 85 / 50 105ZRC-50-2m-85100ZRC-100-2m-85150ZRC-150-2m-85?8 Spiral jointSuitable for long term stable installationY-FCTB502m85110Y-FCT-B50-2m-85B10085Y-FCT-B100-2m-85B15085Y-FCT-B150-2m-85B24050Y-FCT-B240-2m-50?8 High FrequencyH-FCTB502m1.2 / 6.8 / 10 H-FCT-B50-2m-10B95 H-FCT-95-2m-10https://shpytech.en.made-in-china.com/product/gFBazjSxhpcJ/China-STP-Lowest-Rogowski-Coil-Current-Clamp.htmlhttps://shpytech.en.made-in-china.com/product/QFBtYorXXpWb/China-Rogowski-Coil-Handheld-Digital-Power-Quality-Analyzer-with-TFT-Display.htmlhttps://shpytech.en.made-in-china.com/product/WwvtlOXKMmrB/China-Flexible-Rogowski-Coil-Ratio-50mv-Ka-Air-Cored-Current-Sensor-Coil-Current-Transducer.html
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...