IPDB › China Industry › Instruments & Meters
China, Chinese Fluke 1770 Series Fluke1773, Fluke1775, Fluke1777 Three-Phase Power Quality Analyzer1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Test InstrumentBattery TesterFluke1775Fluke1777 Three-Phase Power Quality AnalyzerFluke1773 Power Quality AnalyzerFluke1775 Power Quality Analyzer
BNSENS Co., Ltd.
Preview:
Product DescriptionProduct DescriptionFluke 1770 Series Three-Phase Power Quality Analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord.With the 1770 Series you'll never miss a critical power quality event—from fast transients up to 8 kV, harmonics up to 30 kHz, dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system.Automatic measurement captureWhether you're performing a quick system check or a detailed power quality study, consistent data is key. The Fluke 1770 Series offers a unique automatic measurement capture system that helps ensure you're collecting the right data every time, while still giving you the flexibility to select and adjust specific parameters as needed. More than 500 power quality parameters are captured by default and the guided setup makes it easy to select the right parameters for the system you're working on. Logged data is instantly viewable, downloadable, and shareable with Fluke Energy Analyze Plus software so you never need to wait to finish a session before reviewing results or analyzing data.Ultimate measurement confidenceThe Fluke 1770 Series are 2-in-1 devices that combine the troubleshooting functionality of a power quality meter with the robust analysis and logging capabilities of a standalone power quality analyzer—in a single, easy-to-use, handheld device.The 'PQ Meter' function gives you immediate access to live onscreen data in the field so you can quickly identify potential problems while troubleshooting. The detailed 'PQ Logging and Analysis' function eliminates the complexity of performing power quality studies by guiding you through the setup process ensuring you're capturing the right data every time. Couple these measurement modes with a unique measurement connection autocorrect function and you can be confident that you never need to worry about going back for a second measurement—even if you were unsure about what to look for when you started.Powerful analysis software with easy-to-create reportsFluke 1770 Series Power Quality Analyzers come standard with the powerful Fluke Energy Analyze Plus software, designed to eliminate the hassles found with other multi-purpose application software. Energy Analyze Plus helps you evaluate power quality data right out of the box and without extensive training.Energy Analyze Plus makes downloading, analyzing, tracking, and reporting power quality and energy data easier than ever. Quickly compare results to historical values, benchmark against industry norms, compare measured data to local conditions, and create a more complete picture of what's occurring across your facility, even as the data is still being collected. Energy Analyze Plus offers unified support for the Fluke 1730, 1740, and 1770 Series of Energy Loggers and Power Quality Analyzers.? "In-workshop" and "in-the-field" setup and download through PC application software? Simple data downloads using USB memory stick, WiFi, LTE, wired Ethernet, or USB cable? Analyze every measured detail of energy consumption and power quality state-of-health with automated reporting? One-touch reporting creates standardized reports conforming to standards like EN 50160, IEEE 519, GOST 33073 IEC 61000-2-2, or export data in PQDIF or NeQual compatible format or CSV for use with third-party software? Advanced analysis allows the user to choose any available logged parameter and create a highly customized view of measurements for advanced data correlationHigh-speed voltage transient captureTransients negatively impact otherwise healthy systems every day and their potential to damage your equipment can't be underestimated. Whether your system is experiencing impulsive or oscillatory transients, the results can be devastating and cause problems ranging from insulation failures to total equipment failures. The Fluke 1775 and Fluke 1777 incorporate advanced transient capture technology to help you clearly identify high-speed voltage transients, so you have the data you need to stop them in their tracks. The Fluke 1775 Power Quality Analyzer has 1MHz sampling capability to capture fast transients, while the Fluke 1777 Power Quality Analyzer has 20MHz sampling capability to capture the fastest transients in high detail.From traditional industrial systems to renewable energy systems to electric vehicles, we've got you coveredThe Fluke 1770 Series was designed to be safe and easy to use in any measurement environ?ment. The 1770 Series allows you to capture a full range of power quality variables as well as high-speed waveforms, high-speed transients, and higher frequency harmonics, all of which are instantly viewable on the large, high-resolution screen. With a best-in-class CAT IV 600 V / CAT III 1000 V overvoltage rating, these analyzers can be used at the service entrance or downstream, measuring AC and DC inputs, and harmonics measuring up to 30 kHz. With the 1770 Series you can be confident that you'll capture the data you need to make better maintenance decisions no matter the task.Applications177317751777Energy surveys and load testing???Harmonic surveys???Nuisance circuit breaker tripping??Electric utility power quality surveys??Discovery of equipment failures caused by 8kV microsecond transients??Discovery of equipment failures caused by 8kV nanosecond transients?Compliant to international standardsThe Fluke 1770 Series offers the best-in-class accuracy you've come to expect from a Fluke Power Quality Analyzer in a future IEC 61000-4-30 Class A edition 3 compliant package. On top of that, the 1770 Series has been engineered to meet the future requirements of Class A edition, for conformance to EN 50160 and IEEE 519, so you'll be prepared to tackle tomorrow's measurement requirements, today.Please enter the title hereNo two days in the field are the same. You need a power quality analyzer that can go where you go and do what you need it to when you get there. With a full range of accessories and built-in features the Fluke 1770 Series makes it easier to get your job done. The slim ergonomic design and integrated hand strap make it easy to hold and the included hanging kit makes it easy to secure your analyzer inside a cabinet. The integrated internal power supply allows the unit to be powered directly from the measured circuit, while a 90-minute battery helps ensure you can still access and review data even when you aren't connected to a live system.Quickly and easily transfer data to your PC using the USB C, USB A, Ethernet, Wi-Fi, cellular network support options, depending on your requirements. With an internal GPS module and an optional double insulated antenna extension cable, for amplifying GPS signals indoors, you can easily time sync your data for more accurate troubleshooting and analysis.Calculate current harmonics limitsCalculate money lost to energy waste in terms of real dollars with the Energy Loss CalculatorWhen downloading data from the Fluke 1770 Series Power Quality Analyzers the included Energy Analyze Plus software package can compare measured voltage and current harmonic statistical data to different standards, like EN 50160 or IEEE 519, to determine if they exceed compliance limits. This powerful predictive maintenance feature enables current harmonics to be observed before distortion appears in the voltage allowing you to prevent unexpected failures or non-compliance situations and increase system uptime. With the proliferation of inverter-based loads and power generation, keeping current harmonics in check is becoming increasingly critical to ensure reliable power quality and avoid system downtime.The Energy Loss Calculator (ELC) mode in the Fluke 1770 Series Power Quality Analyzers is designed to discover where energy losses exist in your electrical system using Fluke's patented Unified Power calculation developed by the University of Valencia. In every electrical system, some energy is wasted and that energy is not delivered to the loads in your system to drive them. This waste comes from:? Transmission of effective power – Heat generated as power flows through cables? Reactive power – Does not drive the load but consumes energy? Unbalance losses – Unbalanced loads contribute to wasted energy? Distortion power – Non-linear loads create harmonics that consume power, but do not perform work? Neutral losses – Neutral losses can be due to both unbalance and harmonics, leading to increased heat and requiring larger conductorsFeatures? New Firmware Update: Energy Loss Calculator? Automatically measure power and power quality parameters? At-a-glance power quality health for faster troubleshooting? Easily view V/A/Hz, power, dips, swells, and harmonics data? Capture high-speed transients up to 8 kV? Power directly from measurement circuit without a line cordModel: Fluke 1773 Power Quality AnalyzerModel: Fluke 1775 Power Quality AnalyzerPackaging Includes? FLUKE-1773 Power Quality Analyzer? I17XX-FLEX1500 18 iFLEX 1500A 18 IN (2.0M) current probes (set of four)? FLUKE-17XX flat cable voltage test lead 3-phase+N? AC285 black alligator clips (set of four)? AC285 green alligator clip? Black 1M USB-C cable? Line cords (US, EU, UK, AUS, BRA)? FLK-17XX 0.18M test lead set? Green test lead? Cable marker set (for voltage and current)? FLUKE-174X-MA-C8 wall outlet adapter? Packaging Includes? FLUKE-1775 Power Quality Analyzer? I17XX-FLEX1500 18 iFLEX 1500A 18 IN (2.0M) current probes (set of four)? FLUKE-17XX flat cable voltage test lead 3-phase+N? AC285 black alligator clips (set of four)? AC285 green alligator clip? Black 1m USB-C cable? Line cord? FLK-17XX 0.18M test lead set? Green test lead? MP1-3R/1B Magnet Probe set? FLUKE-174X-HANGER magnetic hanging kit? FLUKE-177X-4204, WI-FI/BLE module? Cable marker set (for voltage and current)? FLUKE-174X-MA-C8 wall outlet adapter? Black soft caseModel: Fluke 1777 Power Quality AnalyzerModel: FLUKE-1777/FPCModel: FLUKE-1775/FPC? Packaging Includes? FLUKE-1777 Power Quality Analyzer? I17XX-FLEX1500 24 iFLEX 1500A IN (2.0M) current probes? FLUKE-17XX flat cable voltage test lead 3-phase+N? AC285 black alligator clip? AC285 green alligator clip ? Black 1m USB-C cable? Line cord? FLK-17XX 0.18M test lead set? Green test lead? MP1-3R/1B Magnet Probe set? FLUKE-174X-HANGER magnetic hanging kit? FLUKE-177X-4204, WI-FI/BLE module? Cable marker set (for voltage and current)? FLUKE-174X-MA-C8 wall outlet adapter? FLUKE-1777 HARDCASE rolling hard caseFluke 1777 Power Quality Analyzer Bundled with Premium Care 1-Year Standard PlanIncludes:? Premium Care 1-Year Standard Plan? FLUKE-1777 Power Quality Analyzer? I17XX-FLEX1500 18 iFLEX 1500A 18 IN (2.0M) current probes? FLUKE-17XX flat cable voltage test lead 3 phase+N? AC285 black alligator clip? AC285 green alligator clip? Black 1m USB-C cable? Line cord? FLK-17XX 0.18M test lead set? Green test lead? MP1-3R/1B Magnet Probe set? FLUKE-174X-HANGER magnetic hanging kit? FLUKE-177X-4204, WI-FI/BLE module? Cable marker set (for voltage and current)? FLUKE-174X-MA-C8 wall outlet adapterFluke 1775 Power Quality Analyzer Bundled with Premium Care 1-Year Standard PlanIncludes:? Premium Care 1-Year Standard Plan? FLUKE-1775 Power Quality Analyzer? I17XX-FLEX1500 18 iFLEX 1500A 18 IN (2.0M) current probes (set of four)? FLUKE-17XX flat cable voltage test lead 3-phase+N? AC285 black alligator clips (set of four)? AC285 green alligator clip? Black 1m USB-C cable? Line cord? FLK-17XX 0.18M test lead set? Green test lead? MP1-3R/1B Magnet Probe set? FLUKE-174X-HANGER magnetic hanging kit? FLUKE-177X-4204, WI-FI/BLE module? Cable marker set (for voltage and current)? FLUKE-174X-MA-C8 wall outlet adapter? Black soft caseSpecificationVoltage inputsNumber of inputs4 inputs, 3 phases and neutral referenced to PE (5 connectors)Measurement category1000 V CAT III / 600 V CAT IVMaximum input voltage1000 V rms / 1000 V dc (1700 Vpk)Nominal voltage rangeWye and single phase: variable (50 V – 1000 V)Delta: Variable (100 V – 1000 V)IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 V – 690 VInput impedance10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PEBandwidthDC to 30 kHz for PQ measurements, excluding transientsResolution24-bit synchronous samplingSampling frequency80 kS/s at 50/60 HzScaling1:1, variable for use of potential transformersVoltage transientsMeasurement range±8 kVSampling rate1775: 1 MS/s1777: 1 MS/s, 20 MS/sBandwidthDC to 1 MHzTriggerAdjustable trigger level. Triggers on high-frequency components > 1.5 kHzResolution14-bit synchronous samplingCurrent inputsNumber of inputs4 inputs 3 phases and Neutral, range selected automatically to attached sensorRangeAC1 A to 1500 A with i17XX-FLEX1500 121 A to 1500 A with i17XX-FLEX1500 181 A to 1500 A with i17XX-FLEX1500 243 A to 3000 A with i17XX-FLEX3000 246 A to 6000 A with i17XX-FLEX6000 3640 mA to 40 A with clamp i40s-EL4 A to 400 A with clamp i400s-ELDC20 A to 2000 A with 80i-2010-EL clampBandwidthDC to 30 kHzResolution24-bit synchronous samplingSampling frequency80 kS/s at 50/60 HzScaling1:1, variableInput voltageClamp: 50 mV / 500 mV rms; CF 2.8Rogowski Coil: 15 mV / 150 mV rms at 50 Hz, 18 mV / 180 mV rms at 60 Hz; CF 4all at nominal probe rangeInput impedance11 kΩAux inputsWired connection with 17XX-AUX adapterNumber of inputs2Input rangeDirect: 0 V dc to ± 10 V dc0 V to 1000 V dcInput impedanceDirect: 2.92 MΩScale factorFormat: mx + b (gain and offset) user configurableDisplayed unitsUser configurable (up to 8 characters, for example °C, psi, or m/s)Data acquisition voltage and currentInput mains frequencyDC, 50/60 Hz15% (42.5 Hz...57.5 Hz, 51 Hz... 69 Hz)Topologies1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye IT, 3-φ Aron/Blondel (2 element delta), 3-φ delta open leg, 3-φ high leg deltaData storageFluke 1773/1775: 8 GB internal (expandable with microSD card)Fluke 1777: 32 GB microSD card (installed)Memory sizeTypical 10 logging sessions of 8 weeks with 1-minute intervals and 100 events.The number of possible logging sessions and logging period depends on user requirementsReal time accuracyInternal: 3 ppm (0.26 s per day, 8 s per month)NTP (internet time): Depending on internet latency, typical < 0.1 s absolute to UTCGPS: < 1 ms absolute to UTCTrend intervalMeasured parameterSee operator manualTrend intervalUser selectable: 1 sec, 3 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 minAveraging interval min/max valuesVoltage, Current: ? cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 Hz)Aux, Power: 200 msTotal harmonic distortionTHD for voltage and current is calculated on 50 harmonicsPower quality measurementsMeasured parameterSee operator manualHarmonicsh0 … h50% fund and RMS for voltage, current and powerPhase angles for voltage and current up to h11Interharmonicsih0… ih50% fund and RMS for voltage and currentSupraharmonics2–9 kHz with 200 Hz bins9–30 khz with 2 kHz binsRMS for voltage and currentHarmonics measurement methodGrouped, sub-grouped and single harmonic bins according to IEC 61000-4-7.Method selected automatically based on configured PQ standard or user configurable.Total harmonic distortionCalculated on up to 50 harmonics (depends on selected PQ standard)Mains signaling2 frequencies in the range from 110 Hz to 3000 HzEventsVoltageDip, swell, interruption, rapid voltage change, mains signaling, waveshape deviation, transientsCurrentInrush currentTriggered recordingsHalf cycle RMS of voltage and current for 10 sWaveform of voltage and current for 10/12 cyclesMains signaling: 200 ms RMS of mains signaling voltage up to 120 sTransients: Waveform of voltage(Fluke 1777: 1 MS/s or 20 MS/s, 500,000 pts, Fluke 1775: 1 MS/s, 25,000 pts)Standard compliancePowerIEEE 1459HarmonicsIEC 61000-4-7: Class 1IEEE 519 (short time and very short time harmonics)FlickerIEC 61000-4-15 Class F1Power qualityIEC 61000-4-30 Class A, IEC 62586 PQI-A-PIPower quality complianceEN 50160 + GOST + NEQUAL + NETCODE + FOLInterfacesEthernet1 Gbit/s 1000BASE-TUSB type AUSB 2.0 high speed for USB flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 500 mAUSB-CUSB 2.0 high speed for data download to PC and calibration (requires USB type A to USB-C or USB-C to USB-C cable)Auxiliary power supply for the Analyzer (requires USB C power adapter PD 2.0 or higher with 9 V 1.8 A support)USB 3.0 super-speed for USB-C flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 900 mAWiFi/BLE module1802.11 ac 2.4 GHz / 5 GHz, support for concurrent access point and client modeBluetooth 5.0/BLEAntenna: Internal and external2LTE/4G module3LTE-A Cat 12Worldwide LTE-A and UMTS/HSPA+ coverageAntenna: External2GPSMCX connector to attach a GNSS antenna for GPS/GLONASS21. Not in 177X/BASIC versions2. Requires 5m extension cable, Fluke p/n 52639153. Availability and supported providers vary by country. Check with your local Fluke representative.Electrical measurement accuracyParameterRangeResolutionIntrinsic Accuracy at Reference Conditions% of Reading + % of Full ScaleVoltage1000 V0.1 V0.1% of nominal voltage in accordance with IEC 61000-4-30 Class A1,2 ±(0.04 % + 0.004%)3Voltage dips and swells-0.1 V0.2 % of Vnom1,2Voltage transients±8 kVpk-±5 % +0.25 %)Voltage harmonics/interharmonics100 %0.1 % / 0.1 mV≥1 % Vnom1: ±2.5 % of rdg. <1 % Vnom1:±0.025 VnomTHD on voltage100 %0.1 % / 0.1 V±(2.5 % + 0.5 %)Voltage distortions 2-9 kHzMax 100 V0.1 mV±(2.5 % + 0.1 V)Voltage distortions 9-30 kHzMax 100 V0.1 mV±(2.5 % + 0.1 V)Current(Rogowski clamp mode)With iFlex 1500 A,i17XX-FLEX1500 18150 A1500 A0.01 %0.1 A±(1 % + 0.02 %)With iFlex 3000 A,i17XX-FLEX3000 24300 A3000 A0.01 A0.1 A±(1 % + 0.03 %)With iFlex 6000 A,i17XX-FLEX6000 36600 A6000 A0.1 A1 A±(1.5 % + 0.03 %)With AC clamp 40 A,i40s-EL4 A40 A0.001 A0.01 A±(0.7 % + 0.02 %)With AC clamp 400 A,i400s-EL40 A400 A0.01 A0.1 A±(2 % + 0.2 %)±(0.7 % + 0.1 %)With AC/DC clamp2000 A, 80i-2010s-EL200 A2000 A0.01 A0.1 A±(0.8 % + 0.2 %)Current min/max100 %defined by accessoryx2 of intrinsic accuracyCurrent harmonics/interharmonics100 %0.1 % / 0.01 A≥3 % Inom:±2.5 % of rdg.4 <3 % Inom:±0.15 % of InoTHD on current100 %0.1 %±(2.5 % + 0.5 %)Frequency42.5 Hz … 69 Hz0.001 Hz±0.01 HzVoltage unbalance100 %0.1 %±0.15 %Current unbalance100 %0.1 %±0.15 %Flicker Pinst, Pst, Plt0 to 200.015 %Mains signaling voltageUp to 3 kHz0-15 % of Vnom0.1 V / 0.1 %1-3 % Vnom: ±0.15 % of Vnom3-15 % Vnom: ±5 % of rdg.AUX input±10 V0.1 mV±(0.2 % + 0.05 %)1Nominal voltage in the range of 100 V to 690 V. Also known as Udin.20 °C to 45 °C: Intrinsic Accuracy x2. Outside of 0 °C to 45 °C: Intrinsic Accuracy x33Only for calibration laboratories4With iFlex 1500A, I17XX-FLEX1500 18°CGeneral specificationsKey featuresWarrantyAnalyzer: 2 years (battery not included)Accessories: 1 year (including battery)Calibration cycle2 yearsSize (L X W X HD)28.0 cm x 19.0 cm x 6.2 cm (11.0 in x 7.5 in x 2.4 in)Weight2.1 kg (4.6 lb)Anti-theft protectionSlot to support Kensington lockEnvironmental specificationsOperating temperature range-10°C to 50°CStorage temperature range-20°C to 60°COperating humidityIEC 60721-3-3: 3K5, modified:-10°C to 30°C: ≤95 %, no condensation or ice35°C: 70 %40°C: 55 %50°C: 35 %IP RatingIEC 60529: IP50VibrationIEC 60721-3-3 / 3M2Power supplyVoltage range100 V – 600 V -15 % / +10 % (85 V … 660 V)Power consumptionMax. 40 VAMains frequency50/60 Hz (42.5 Hz … 69 Hz)UPSLi-Ion battery BP1770 with extended temperature range, customer replaceableOn-battery runtime: 1.5 hoursSafetyGeneralIEC 61010-1: Pollution Degree 2Power supplyOvervoltage Category IV 600 VWith Mains Adapter MA-C8: Overvoltage Category II 300 VMeasurementIEC 61010-2-030: CAT IV 600 V, CAT III 1000 VAltitudes 2000 m to 4000 mDerate to:Power Supply: Category IV 300 VWith MA-C8 Adapter: Category II 150 VMeasurement: CAT IV 300 V, CAT III 600 V, CAT II 1000 VCompany Profilehttps://bnsens.en.made-in-china.com/BNSENS (Nanjing) Sensor Technology Co., Ltd. is located in Nanjing, China. It is a high-tech enterprise specializing in the development, manufacturing and trade of sensor products. The company has brought together a group of outstanding technical experts in various fields such as automation, electronics, machinery and computers. All employees of the company have college degrees or above. It adopts the world-class management and operation model and 6 sigma quality system. At present, the company's main products are pressure, liquid level, flow, current, switches, etc. The company's users are all over the country, and some products have been exported to Japan, South Korea and Southeast Asia.Since its inception, the company has been based on the technical accumulation and management standards of American sensor giants. It is composed of senior engineers and managers who have served in multinational companies for many years, and has rapidly developed various pressure sensors, transmitters, liquid level, flow meters, pressure switches, digital meters, current sensors, proximity switches and other products. After years of unremitting efforts, it has become one of the leading suppliers in the domestic automation industry. Our pressure transmitters can achieve an accuracy of more than 3/10,000. The products have been widely used in oil, natural gas, electricity, chemical industry, metallurgy, building materials, food, light industry, environmental protection, aerospace, tap water, municipal and other industries.It is a sensor science and technology innovation company that masters the core technology of MEMS chips. The company has a research and development center in Minnesota, USA. The leader is Dr. Pan Hanjin, a famous scientist in the sensor industry. Dr. Pan Hanjin has been deeply involved in the sensor industry for more than 20 years and is an expert in the sensor industry.The company has a number of ASIC chips independently developed, which are widely used in industrial, automotive, home appliance and other markets.BNSENS (Nanjing) Sensing Technology Co., Ltd. is a strategic partner of Honeywell in China. The two parties proposed a plan of East serving East and jointly developed several sensors specifically for the Chinese market. These sensors will be widely used in intelligent manufacturing, Internet of Things, artificial intelligence, and smart home fields. These sensors include: magnetic sensors, temperature sensors, humidity sensors, force sensors, fire water pressure sensors, equipment vibration sensors, human body status monitoring sensors, motion sensors, etc.History of BNSENS Company:BNSENS is a company focusing on sensors, instruments, and electronic components. We are a young company, founded in 1999, just 25 years old, and we are still growing.1999: The company's first pressure sensor was launched, mainly for the petroleum and petrochemical industries.2002: The company expanded its product line and launched temperature sensors2005: Started producing high-precision pressure sensors for the test and measurement market2006: Became an official authorized agent of Honeywell2009: Introduced the Six Sigma management system, and the product qualification rate was greatly improved2010: Became a supplier of Emerson2011: We started selling SICK sensors2014: Introduced the sensor production line from Germany, developed more industrial control sensors, and cooperated with TSMC2015: Cooperated with Siemens in Vietnam2017: The factory moved to Nanjing High-tech Zone2019: Became a national high-tech enterprise in China2023: We started selling products from Infineon and Rohm2025: We started cooperating with FlukeBNSENS,The Future Starts Here.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...