China, Chinese 393FC True RMS Digital Clamp Meter with Iflex1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Electronic InstrumentClamp Meter393FC378FC
Shenzhen HOBOY Instruments Co., Ltd.
Preview:
Product Description Ideal for technicians who work in dc environments up to 1500 V, this true-rms clamp meter features a slim jaw to allow access to crowded combiner boxes and is IP54 rated for work outdoors. In addition, this meter features a flexible current probe that extends AC current measurements up to 2500 A.FeaturesIP54 rated, ideal for work outdoors in dusty or damp conditions on solar arrays and wind power systemsDC power measurement, showing readings in kVAAudio polarity indicator helps prevent accidental miswiresVisual continuity turns provide a bright green light in the display, ideal when working in dark and noisy environmentsLogging and reporting of test results via softwareMeasure safely with CAT III 1500 V rated clamp meterThin jaw for access to cables in crowded combiner boxes, able to clamp around multiple cablesMC4 test lead sets are designed for use with solar clamp meters that accept 0.15" (4 mm) banana plugs, rated to CAT III 1000 V / CAT IV 600 VView voltage and current simultaneously with the meter's dual displayFluke 393 FC - CAT III 1500V TRMS Wireless Clamp Meter with iFlex (2500 A AC/999.9 A DC) Maximum AC current = 2500 AMaximum DC current = 999.9 AMaximum AC voltage = 1000 VMaximum DC voltage = 1500 VTrue RMS = yesThe 393 FC CAT III 1500 V True-RMS Clamp Meter with iFlex is designed for technicians who work in high voltage DC environment: solar arrays, wind power, electric railways, data centers battery banks for uninterruptible power supplies. The clamp will measure up to 1500 V DC, 1000 V AC, and up to 999.9 A DC or AC through the clamp jaw. The included iFlex flexible current probe extended AC current measurements up to 2500 amps. This clamp has a thin jaw, giving you access to cables in crowded combiner boxes. Test leads are designed with your work in mind and are also rated to CAT III 1500 V DC.Product ParametersMaximum Voltage Between Any Terminal and Earth Ground1000 V AC1500 V DCElectrical SpecificationsAccuracy: Accuracy is specified for 1 year after calibration, at operating temperatures of 64.4 to 82.4°F (18 to 28°C), relative humidity at 0 to 75%. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])Temperature coefficients: Add 0.1 x specified accuracy for each °C > 64.4°F (28°C) or <82.4°F (18°C)AC Current: JawRange: 999.9 AResolution: 0.1 AAccuracy: 2% + 5 digits (10 to 100 Hz); 2.5% + 5 digits (100 to 500 Hz)Crest factor (50/60 Hz):2.5 at 600 A3 at 500 A1.42 at 999.9 AAdd 2% for C.F. >2AC Current: Flexible Current ProbeRange: 999.9 A; 2500 AResolution: 0.1 A (≤999.9 A); 1 A (≤2500 A)Accuracy: 3 % RD + 5 digits (10 to 500 Hz)Crest factor (50/60Hz):2.5 at 1400 A3 at 1100 A1.42 at 2500 AAdd 2% for C.F. >2Position SensitivityDistance from optimum:ABCi2500-18 Flex:1.4" (35.6 mm)2" (50.8 mm)2.5" (63.5 mm)Error:±0.5%±1%±2%DC CurrentRange: 999.9 AResolution: 0.1 AAccuracy: 2% RD + 5 digits, When using the ZERO function to compensate for offsetsAC VoltageRange: 600 V; 1000 VResolution: 0.1 V (≤600 V); 1 V (≤1000 V)Accuracy: 1% RD + 5 digits (20 to 500 Hz)DC VoltageRange: 600 V; 1500Resolution: 0.1 V (≤600 V), 1 V (≤1500 V)Accuracy: 1% RD + 5 digitsmV DCRange: 500 mVResolution: 0.1 mVAccuracy: 1% RD + 5 digitsAmps Frequency: JawRange: 5 to 500 HzResolution: 0.1 HzAccuracy: 0.5% RD + 5 digitsTrigger level:5 to 10 Hz ≥10 A10 to 100 Hz, ≥5 A100 to 500 Hz, ≥10 AAmps Frequency: Flexible Current ProbeRange: 5 to 500 HzResolution: 0.1 HzAccuracy: 0.5% RD + 5 digitsTrigger level:5 to 10 Hz ≥10 A10 to 100 Hz, ≥5 A100 to 500 Hz, ≥10 AVoltage FrequencyRange: 5 to 500 HzResolution: 0.1 HzAccuracy: 0.5% RD + 5 digitsTrigger level:5 to 20 Hz, ≥5 V20 to 100 Hz, ≥5 V100 to 500 Hz, ≥10 VDC PowerRange: 600 kVA (600 V DC range), 1500 kVA (1500 V DC range)Resolution: 0.1 kVA, 1 kVAAccuracy: 2% RD + 2 kVA, 2% RD + 20 kVAResistanceRange: 600 Ω, 6000 Ω, 60 kΩResolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 0.01 kΩ (≤60 kΩ)Accuracy: 1% RD + 5 digitsCapacitanceRange: 100 μF, 1000 μFResolution: 0.1 μF (≤100 μF), 1 μF (≤1000 μF)Accuracy: 1% RD + 5 digitsInrush trigger level: 5 ATemperatureOperating: 14 to 122°F (-10 to 50°C)Storage: -40 to 140°F (-40 to 60°C)Operating HumidityNon-condensing <50°F (10°C)≤90% RH at 50 to 86°F (10 to 30°C)≤75% RH at 86 to 104°F (30 to 40°C)≤45% RH at 104 to 122°F (40 to 50°C)AltitudeOperating: 6561.68' (2000 m)Storage: 39,370.07' (12,000 m)Electromagnetic Compatibility (EMC)International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.Korea (KCC): Class A equipment (Industrial Broadcast and Communications Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.SafetyGeneral: IEC 61010-1, Pollution Degree 2Measurement:IEC 61010-2-032: CAT III 1500 V / CAT IV 600 VIEC 61010-2-033: CAT III 1500 V / CAT IV 600 VWireless RadioRadio frequency certification: FCC ID: T68-FBLE, IC: 6627A-FBLEWireless radio frequency range: 2400 to 2483.5 MHzOutput power: <100 mWSIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.Automatic Power Off20 minutesDisplayDual display with backlightBatteriesTwo AA IEC LR6 alkalineDimensionsSize: 11.06 x 3.3 x 1.92" (281 x 84 x 49 mm)Jaw opening: 1.33" (34 mm)Flexible current probe diameter: 0.29" (7.5 mm)Flexible current probe cable length (head to electronics connector): 0.07" (1.8 m)Weight (With Batteries)1.14 lbs (520 g)
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...