IPDB › China Industry › Industrial Equipment & Components
China, Chinese High Voltage 3.3kv 6kv 6.6kv 10kv 10.5kv 11kv 13.8kv 1000-4000kVA Kw Cummins/Perkins/Mtu/Baudouin/Mitsubishi/Yuchai Engine Electric Diesel Generator1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Power Generating SetsDiesel GeneratorHigh Voltage Generator2500kVA Generator
MECCA POWER CO., LTD.
Preview:
Product Description Company ProfileFor over a decade, MECCA POWER has been a trusted leader in designing, manufacturing, and supplying high-performance diesel generator sets for demanding industrial and commercial applications worldwide. We specialize in delivering customized, reliable power solutions for large-scale projects where uninterrupted electricity is mission-critical.Our diesel generators ranging from 10kVA to 4000kVA, are engineered to meet the rigorous demands of various application like Telecom,Data Centers,Mining,Power Plants,Construction,Oil & Gas, and more, ensuring your operations run smoothly and efficiently.As a prestigious OEM, we maintain a sound relationship with our main material suppliers, such as Cummins, Perkins, MTU,Mitsubishi,FPT,VOLVO, Baudouin,Stamford, Leroy Somer, Mecc Alte, DeepSea, ComAp, Chinese engine brand,etc.Product DescriptionMECCA POWER delivers high-voltage generator sets engineered for resilience, precision, and peak performance in the most demanding environments. Our range of 3.3kV to 13.8kV generators, with capacities spanning 1000kVA to 4000kVA, provides robust backup or prime power solutions for large-scale facilities, infrastructure, and mission-critical operations worldwide.Key Features:Wide Voltage Range: Flexible output options (3.3kV, 6.6kV, 11kV, 13.8kV) tailored to match your grid or equipment requirements.High Capacity: Scalable from 1000kVA to 4000kVA for industrial, utility, and commercial applications.Premium Engine Integration: Customizable with globally trusted engine brands including Cummins, MTU, Perkins, Yuchai, Mitsubishi/SME,Baudouin, and more-ensuring fuel efficiency, durability, and compliance with global emission standards.Engineered Reliability: Advanced voltage regulation (±1%), integrated protection systems, and rugged construction for 24/7 operation in extreme conditions. View more products click here... Specification Powered by SME 50HZ 220-440V 688-2500KVA ModelLTPPRPEngineFuel Cons.L/HCyl.Disp.Gov.Dimention L*W*H (MM)Weight (KGS)KVA / KW KVA/KW ModelOrigin100%LOpenOpenMC688MS688 550 625500 S6R2-PTA-CCN1396L30.0 E3770*1400*20006140 MC825MS825660 750600 S6R2-PTAA-CCN1706L30.0 E4100*1400*21506410 MC1375MS13751100 12501000 S12R-PTA-CCN26612V49.0 E4880*2000*238010560 MC1540MS15401232 14001120 S12R-PTA2-CCN28112V49.0 E4980*2000*238010660 MC1650MS16501320 15001200 S12R-PTAA2-CCN30812V49.0 E4980*2200*238010860 MC1915MS19151532 17501400 S16R-PTA-CCN31016V65.4 E5490*2190*249511410 MC2100MS21001680 18751500 S16R-PTA2-CCN41816V65.4 E5640*2170*249511710 MC2250MS22501800 20501640 S16R-PTAA2-CCN43216V65.4 E5820*2210*267013500 MC2500MS25002000 22501800 S16R2-PTAW-CCN47616V79.9E6790*2200*252516400 MC2500MS25002000 22501800 S16R2-A2PTAW-CCN47616V79.9E6790*2200*252516400 MC2750MS27502200 25002000 S16R2-PTAW2-E-CCN52816V79.9E7230*3064*376220000Powered by Mitsubishi 50HZ 220-440V 825-2750KVA ModelLTPPRPEngineFuel Cons.L/HCyl.Disp.Gov.Dimention L*W*H (MM)Weight (KGS)KVA / KW KVA/KW ModelOrigin100%LOpenOpenMC825MT825660 750600 S6R2-PTAAJP1706L30.0 E4100*1400*21506410 MC880MT880704 800640 S12A2-PTAJP17412V33.9E4350*1900*23106410 MC1100MT1100880 1000800 S12H-PTAJP22012V37.1E4880*2000*23809860MC1400MT14001120 12501000 S12R-PTAJP26612V49.0 E4880*2000*238010560 MC1540MT15401232 14001120 S12R-PTA2JP28112V49.0E4980*2000*238010660MC1650MT16501320 15001200 S12R-PTAA2JP30812V49.0E4980*2200*238010860MC1915MT19151532 17501400 S16R-PTAJP31016V65.4E5490*2190*249511410MC2100MT21001680 18751500 S16R-PTA2JP41816V65.4E5640*2170*249511710MC2250MT22501800 20501640 S16R-PTAA2JP43216V65.4E5820*2210*267013500MC2500MT25002000 22501800 S16R2-PTAWJP47616V79.9E6790*2200*252516400MC2750MT27502200 25002000 S16R2-PTAW-EJP52816V79.9E7230*3064*376220000Genset WorkshopFAQ1.Q: What is your MOQ of this item?A:1 Set2.Q: What are your payment terms?A:30% TT as deposit,70% TT before Shipment or 100% LC at sight3.Q:What's the warranty time of diesel generators?A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.4.Q:Can you accept the customized products?A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples5.Q:What's the delivery time ?A:20 to 35 days after receiving your payment in advance.6.Q:Do you offer OEM service?A: Yes7.Q:What is the power range do you have?A:Mecca Power assemble genset from 2 to 4000kva8.Q:What's your special compare to other manufacturer?A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.Beside genset one-stop purchasing service to world-wide customers,CKD and SKD packing service are also available according to unique request.CKD:Complete Knock Down GeneratorGenerator completely knocked down into parts without assembling. All items from following are seperately packed without connection. SKD:Semi Knock Down GeneratorPartially assembled generator. Part of the following items you choose will be assembled.-----------------------------------------------------------------------------------------------MAITAINENCE---------------------------------------------------------------------------------------------General Troubleshooting This section lists the generating set for some common fault, the reasons for the failure and determines the method of fault. General operators can determine their own fault and note, maintenance it according to the brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation. Please remember the following suggestions before repairing: - Make sure that study the failure carefully before any operation. - Repair with the easiest way and most commonly used method. - Find the exact causes of failure and completely solve the fault. 1. Generator Sets Description of this section is for reference only. If the following failure occurs please contact the repairing agents. (Some models of control panel installed only parts of the following warning indicator light)IconIndicator LightReasonFault AnalysisLow oil pressurealarmLow oil pressurealarmWhen oil pressure does notreduce normally, the light is on.-General because of a lack of oil or lubricationsystem failure caused by (refueling or replacingthe oil filter)-When occurs this fault should automaticallyshutdown generator sets immediately.High watertemperaturealarmHigh watertemperaturealarmWhen the water temperaturehas risen to a level higher thanor equal to the sensor setting,the light is on.-General because of a lack of water or oilshortage, or overload.-When occurs this fault should automaticallyshutdown generator sets immediately.Low fuel levelalarmLow fuel levelalarmWhen a fuel level has beendetected by the sensor fitted tothe daily tank, the light is on.-General because of a lack of water or oilshortage, or overload.-When occurs this fault should automaticallyshutdown generator sets immediately.Battery chargerfault alarmBattery chargerfault alarmIf the charging system has fault,when engine running, the light isoff.-Battery charging system fault caused.-The light is on at the initial start, when thecharger reaches a certain speed, the light is off.-This failure will not lead to automatic shutdowngenerating units.Crank failurealarmCrank failurealarmWhen the generator set failedthree times (or six times) in arow starting, the light is on.-Oil supply system or re-start the system failurecaused.Overload orbreaker trippingalarmOverload orbreaker trippingalarmWhen overloading or Shortcircuit, the light is on. Trippingcircuit breakers cause generatorset load out.-In this fault, it need to load or unload some partsto eliminate short-circuit, and then re-close thecircuit breaker.Introduction of Maintenance grade(Interval) for the generator set A Level Maintenance Interval (Daily Maintenance)1. Check Daily Report of Genset .2. Check fuel level and coolant level. 3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or other damage.4. Check the Air filter. The air filter should be replaced when necessary .5. Release fuel tank and fuel filter's water and sediment.6. Check the water cooling filter.7. Check starting battery and electrolyte, add electrolyte when necessary. 8. Check the starter, check noisy defect.9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.B Level Maintenance Interval (Less than 400 hours)1. Repeatedly check A Level Daily Maintenance steps.2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice and real fact. 3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF Grade of American Petroleum Institute.4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or it can be replaced. The replacement must be according to the environment and real fact.5. Replace the cooling system and add coolant concentration.6. Clean the crankshaft and inlet, outlet air- filter net. C Level Maintenance Interval (2000-3000 hours), Please do as follows:1. Repeatedly check A and B Level Daily Maintenance steps.2. Remove the tap of valve, clean and wash oil dirt and sludge.3. Fasten snails from each part (including running parts and fixed parts)4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.6. Check and adjust valve clearance.7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; clean and wash water tank radiator fins, then check the using capability of thermostat.Current Repair (D Level Maintenance)(3000-4000 hours)1. Check valve, valve seat and other wearing, repair or change it when necessary.2. Check P pump, quality of injection, repair and adjust it when necessary.3. Check and adjust connecting rod and fastening twisting torque.4. Check and adjust valve clearance.5. Check the trip of injector.6. Check and adjust tension of fan and generating belt.7. Clean and wash accumulation of carbon in inlet pipes.8. Clean and wash the core of air cooler.9. Clean and wash the whole oil lubrication system.10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.Medium Repair (6000-8000 hours)1. Including the items of minor repair.2. Disassemble generator(except crankshaft)3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.4. Check fuel supplying system, adjust oil pump and injector.5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.Overhaul (9000-15000hours)1. Including the items of intermediate repair.2. Disassemble all the parts in the generator.3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake and exhaust valve, a whole set of tools for generator repair 4. Adjust oil pump, injector and replace pump core, injector5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...