Send

Food Packaging Bag

Gift Box & Bag

Industrial Packaging Bag

Logistics Packaging

Machinery for Packaging Supplies

Non Woven Bag

Other Bags & Cases

Package & Conveyance

Package & Printing Service

Packaging Bags

Packaging Materials

Packing Bottle

Packing Machinery

Post-Press Equipment

Pre-Press Equipment

Printing Machinery

Printing Materials

Shopping Bags

Specialized Case & Box

Stencil

Tag & Sign

Tag Gun

Tool Packaging

Watch Box

IPDBChina IndustryInstruments & Meters



China, Chinese Portable Pump Diffusion Gas Detector1 Industrial Products Supplier Manufacturer Details, price list catalog:

China Industrial Products Supplier Manufacturer List Catalog
« Previous Next »

Meter for Liquid GasOther Meters for Liquid GasPortable Pump DetectorPortable Diffusion Detector

Chongqing Jiuxin Automation Technology Co., Ltd

Preview:

Product Description Portable Pump Diffusion Gas DetectorProduct Description Portable gas detectors are essential tools designed to quickly and accurately identify gas leaks or trigger alarms when gas concentrations exceed safe levels. They operate based on various detection principles, including electrochemical sensors, infrared technology, catalytic combustion, thermal conductivity, and PID (photoionization detection). These devices are widely used across a range of industries and scenarios, such as fire protection, emergency rescue, confined spaces, oil and gas, chemical processing, metallurgy, refining, warehousing, pharmaceuticals, environmental monitoring, and air quality management. Product Features Multi-Gas Detection: Can detect 1 to 4 gases simultaneously (depending on the specific product).Measurement Units: Supports optional units such as μmol/mol, PPM, mg/m3, %Vol, and %LEL.Measurement Methods: Diffusion or pump-based measurement, with an external pump seamlessly integrated into the instrument.Fall Alarm: Equipped with a fall detection alarm for enhanced safety.Data Storage:Standard storage capacity: at least 200,000 records (customizable for larger storage).Supports multiple storage methods: real-time storage, scheduled storage, or alarm-only storage.Allows local viewing and deletion of data. Data can be uploaded via USB for analysis or printing.Battery: Powered by a 1400 mAh rechargeable polymer lithium battery.Data Recovery: Misoperation recovery function allows restoration of partial or full factory data.Customizable Display: Users can choose to display maximum, minimum, or weighted average values.Alarm Settings:Multiple alarm modes: sound, light, and vibration.Alarm types: concentration, under-voltage, fault, and pump clogging.Alarm thresholds: low, high, interval, and TWA/STEL alarms.Smart Features:Misoperation recognition: Prevents calibration errors caused by human factors.Automatic zero-point tracking: Ensures zero-point drift does not affect long-term use.Multi-level calibration: Ensures measurement linearity and accuracy.User Interface: Supports both Chinese and English interfaces.Environmental Adaptability:Operating temperature: -20°C to +55°C (typical) and -40°C to +70°C (limit).Equipped with temperature compensation.Additional Features:Sensor life expiration reminder and calibration time notification.Intrinsically safe circuit design, with anti-static and anti-electromagnetic interference capabilities.Protection rating: IP68 (rain-proof, immersion-proof, dust-proof, and corrosion-resistant)Product Parameters Detect gas 1-4 types of gases (carbon monoxide CO, hydrogen sulfide H2S, oxygen O2, flammable gas Ex, carbon dioxide CO2, VOC , etc.)Depends on site environment and user needs Application occasions Petroleum, chemical industry, medicine, environmental protection, gas distribution, warehousing, flue gas analysis, air treatment and other occasions that require portable and rapid detection of gas concentration. Detection range 0~1, 10, 100, 1000, 5 000, 5 0000 , 100000 ppm, 100% LEL, 20% , 50%, 100% Vol are optional, other ranges can be customized . Resolution 0.01ppm or 0.001ppm (0~10 ppm);0.01ppm (0~100ppm);0.1ppm (0~1000ppm);1ppm (0~1000 ppm and above);0.1%LEL ;0.01%Vol;0.001 %Vol; Detection principle Electrochemistry, catalytic combustion, infrared, thermal conductivity, PID photoionization , etc. , depending on gas type, range, on-site environment and user needs. Sensor life 2 to 3 years for electrochemical principles , 5 to 10 years for infrared principles , 3 years for catalytic combustion, 5 years for thermal conductivity , and 2 to 3 years for PID photo ions . Accuracy  ≤± 3 %FS (higher accuracy can be customized) Response timeT90 ≤ 3 0 seconds Recovery Time ≤ 3 0 seconds working environment Temperature: -20 ~ +55 oC ( typical value) -40 ~ +70 oC ( limit value) , humidity: 10 ~ 95 %RH (normal) non-condensing conditions Temperature & humidity Optional: temperature - 40 oC~+ 120 oC , accuracy 0.5 oC ; humidity 0 ~ 100 %RH , accuracy 3 %RH Working power 7.4 VDC, 1400mAh large capacity rechargeable polymer lithium battery Display 2-inch LCD display Detection method Diffusion/pumping type, standard configuration: external pump Alarm mode Sound and light alarm , vibration alarm, sound and light + vibration alarm, and shutdown alarm can be set Communication Interface Standard Type-C fast charging and communication, equipped with charging base Data storageStandard data storage capacity is no less than 200,000 pieces (larger capacity can be customized) Protection level IP68 Explosion-proof type intrinsically safe Explosion-proof signs Exia IIC T 4Ga Implementation standardsGB 15322.3-2019 " Combustible Gas Detectors Part 3: Portable Combustible Gas Detectors for Industrial and Commercial Use "GB T50493-2019 " Design Standard for Detection and Alarm of Combustible and Toxic Gases in Petrochemical Industry "GB 12358-2006 "General technical requirements for ambient gas detection and alarm devices in workplaces"GB 3836.1-20 21 "General Requirements for Electrical Equipment for Explosive Gas Environments"GB 3836.4-20 21 "Intrinsic safety type "i" of electrical equipment for use in explosive gas environments" Dimensions 90 × 70 × 38mm (L×W×H) Weight About 380g Standard accessories Instructions, certificate, warranty card, USB charger (including data cable) , charging base, instrument case , external pump (calibration cover), 1 filter Options Optional multiple filters, 0.4m stainless steel sampling  Common faults and solutions Fault 1: Unable to Detect at Low ConcentrationsSolutions:Confirm whether the target gas is present at the site.Perform zero-point calibration by using nitrogen gas or clean air. Test immediately after calibration.If the issue persists after zero-point calibration, restore the factory settings.Repeat the calibration process with nitrogen or clean air if detection still fails after restoring factory settings.If the above steps do not resolve the issue, contact the manufacturer's after-sales support. Fault 2: Fluctuating or Randomly Jumping Values in the Air Without the Target GasSolutions:Check for temperature and humidity fluctuations at the site, as these can cause temporary instability in readings. Once stabilized, the values should return to normal.Verify whether zero-point or target-point calibration was performed in the presence of target gas. Factory reset can resolve issues caused by incorrect calibration values.If high-concentration gas has impacted the sensor, power on the instrument and allow it to age for 24 hours. If values remain unstable, the sensor may be damaged and require replacement. Fault 3: Inaccurate DetectionSolutions:Confirm the actual concentration of the target gas on site. To ensure accuracy, use standard gas for verification or send the instrument to a third-party testing agency.Check the sensor's condition. Long-term use may cause errors in readings. If the sensor is nearing the end of its service life, replacing it is recommended for optimal performance. Fault 4: Alarms Triggered When the Value is Zero or Below the Alarm ThresholdSolutions:Verify whether the alarm threshold has been modified.Check the alarm settings, including the mode and type of alarm.Identify whether the alarm is a concentration alarm or a fault alarm:Concentration Alarm: Displays "AL" or "AH" and flashes a red indicator.Fault Alarm: Activates a yellow light.If the alarm is caused by incorrect settings, restore the factory settings. For fault alarms, inspect for issues such as short circuits, open circuits, poor contact, or sensor failure. If unresolved, send the device to the manufacturer for inspection. Fault 5: Unable to Communicate with the ComputerSolutions:Ensure the device address matches the address set in the communication software.Check the serial port in the computer's Hardware-Device Manager-Port section. For USB interfaces, confirm the correct port number and default baud rate (9600). Fault 6: No Data Records Found in QuerySolutions:Verify that the storage function is turned on (refer to Chapter 7 of the user manual for storage settings).If the storage function is enabled but no records appear, ensure data recording was initiated. Perform the following steps:Navigate to Data Recording > Data Deletion to reset data recording. Wait 15 minutes and check again.Confirm that the start and end times for the query match the measurement period. Ensure the instrument's internal clock is accurate and properly synchronized.If the system time is incorrect, the mainboard may need repair. Return the instrument to the factory for servicing.Company Profile We focus on the market, prioritize quality, drive continuous innovation, master core technologies, and serve our customers with dedication. The company is equipped with the necessary detection equipment and technical capabilities to produce high-quality gas detection instruments, demonstrating professionalism and commitment. With a strong reputation in the gas detection field and high customer recognition, we provide reliable support for pre-sales consultation and after-sales service.Our product development, design, and research are aligned with market demands as well as quality and technical standards. The instruments feature elegant designs, stable detection performance, and explosion-proof configurations, suitable for both fixed gas detectors and portable devices. Thanks to our consistent product quality, we have obtained national licenses for manufacturing measuring instruments, national explosion-proof electrical product certifications, and qualifications for the installation and maintenance of explosion-proof electrical equipment.Guided by the service philosophy of "perfection, efficiency, and innovation," we are committed to offering society and enterprises safe and reliable solutions to ensure stable production and secure everyday life. Packaging & Shipping  

Link supplier or manufacturer »

Instruments & Meters: Portable Pump Diffusion Gas Detector
Inscinstech Protein Purification System (Unique AutoPure300) Protein Purification Techniques1603byte
ID200*650 Preparative Purify HPLC System1844byte
Fps-100c Single Channel Automatic Peptide Synthesizer1323byte
Inscinstech Lab Instrument Automatic Large Scale Oligonucleotide Synthesizer (Unique AutoOligo25) for The Rapid Synthesis of 10~100μ Mol Nucleic Acid Samples648byte
ID1400*500mm Auto Acrylic Column Column, Bed Lenght 500mm1439byte

ID600mm Purify HPLC System for Natural Plant1537byte
Inscinstech Automatic Large Scale Oligonucleotide Synthesizer (Unique AutoOligo100) for The Rapid Synthesis of 50 μ Mol-9 Mmol Nucleic Acid Samples640byte
Factory Price HPLC High Performance Liquid Chromatography with Isocratic And Gradient System2545byte
Chromatographic Columns USP L1 L8 L11 L10 L Ods Cn C18 C8 Normal Phase / Reverse Phase HPLC Column4416byte
Inscinstech Lab Instrument Protein Purification System (Unique AutoPure150-L1) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP822byte

50dac Preparative Purify HPLC System2241byte
High Efficiency One Stop Solution Chromatograph Machine HPLC Systems High Performance Liquid HPLC Chromatography2545byte
Laboratory High Performance Liquid Chromatography Machine HPLC Chromatography LC-W100A2771byte
LC Laboratory High Performance Liquid Chromatography HPLC with UV Detector for Food Analysis7365byte
100ml Fplc Chromatography for Cetuximab1701byte

Inscinstech Ion Chromatography Protein Purification System (Unique AutoPure25-L1) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP811byte
Biobase HPLC High Performance Liquid Chromatography System Gas Chromatograph5402byte
Biobase Eclassical 3100 Laboratory High Performance Liquid Chromatography System for Laboratory HPLC1278byte
Mass Spectrometer Gas Chromatograph with Fid Detector4942byte
Dw-Gc1120 Economic Gc System Gas Chromatography Fid Tcd Ecd Npd Lab Gas Chromatograph Machine3011byte

High Accuracy Transformer Oil Gas Analyzers Price Dissolved Gas Analysis Equipment GC MS Insulating Oil Gas Chromatograph3258byte
SCITEK Gas Chromatograph Self-Diagnostic System Chromatograph With Seamless PC Control3341byte
Explosion Proof Real-Time Industrial Online Process Analyzer Industrial Online Gas Chromatograph4030byte
Double Beam UV-Vis Spectrophotometer / Spectroscopy Instrument1546byte
2025 RoHS Directive Detection Edxrf Energy Dispersive X-ray Fluorescence Spectrometer2432byte

Gas Chromatograph Mass Spectrometer Gc-Ms4084byte
Laboratory High Performance Liquid Chromatography HPLC with UV Detector for Food Analysis952byte
Inscinstech Protein Purification System Lab Instrument (Unique AutoPure100-L2) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP1569byte
1000ml Ss Pump for Ion Chromatography Pump1448byte
Gc112A Lab Gas Chromatograph Analysis Instrument2874byte

Alva SPD620 Laboratory Sample Pretreatment Digestion Instrument with Metal Heating Module, Chemistry Lab Instrument7790byte
China Factory High Efficiency Kjeldahl Digestion Furnace for Lab Use2011byte
High Precision High Frequency Infrared Carbon Sulfur Analyzer for Alloy Plant5415byte
Carbon Silicon Tester for Foundries Is Used for Pre-Furnace Scarbon Silicondetection of Gray Cast Iron Ductile Cast Iron Foundry Molten Iron Testing Equipment3289byte
Unparalleled Accuracy in Carbon Sulfur Testing with Our Superior Technology Xrf ACP Aas Manufacture6697byte

Aurispec P3 Xrf, Portable Analyzer, Gold Tester, Spectrometer1348byte
Automatic Fat Analyzer SD-P6s for Measuring Fats and Other Compounds Using The Soxhlet Extraction Principle8780byte
Sequential Inductively Coupled Plasma Emission Spectrometer-Icp-Oes/Icp-AES 5% off1756byte
Automatic Kjeldahl Nitrogen Analyzer for Food Crops and Feeds2445byte
High Precision Portable Chlorophyll Meter3412byte

High Precision and Speed with Mining Steel Carbon Sulfur Analyzer6697byte
Digital Oxygen Nitrogen Hydrogen Analyzer for The Determination of Steel1896byte
Aurispec B6t, Benchtop Xrf, Coating Thickness Analyzer, Element Analyzer, Soil, Spectrometer2421byte
Casting Furnace Front Carbon and Silicon Analyzer Automatic Analysis and Automatic Printing5945byte
Fd6800 Fiber Analyzer: Fully Automated Chemistry Elemental Analyzer for Sensitive Detection of CF, Adf, Ndf, Cellulose, and Lignin8082byte

Nanbei Crude Protein Analysis Automatic Kjeldahl Nitrogen Analyzer5041byte
Drawell Portable Xrf Gold Tester Handheld Xrf Mineral Analyzer X-ray Fluorescence Spectrometer2331byte
CS995 High-Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral Coal3201byte
Handheld Smart Mini Poct Automated Blood Gas and Electrolyte Analyzer Electrode Method Blood Analyzer for Hospital Use (SG1)1327byte
Hand-Held Pesticide Residue Meter for Food Safety Meter4150byte

Xrf Sulfur Analyzer X-ray Sulfur Analzyer 5% off1089byte
Desktop Liquid Security Detector Liquid Trace Detector695byte
High Quality Single Flame Atomic Absorption Spectrometer for Lab4823byte
Innovate High-Frequency Infrared Carbon & Sulphur Analyzer5536byte
Carbon Silicon Analyzer for Molten Iron Fast Foundry Thermal Analysis System Cup Sampling Furnace QC Testing Carbon Equivalent Measurement on-Site Liquid Metal5549byte

Full Automatic High Frequency Laboratory Equipment Analysis Instrument Testing Machine Metal Detector Chemistry Analyzer Metal Infrared Carbon Sulfur Analyzer6669byte
Semi-Auto Kjeldahl Protein Analyzer From Factory2538byte
High-Precision Kjeldahl Nitrogen Protein Measurement Equipment for Labs3768byte
Aurispec H3 Xrf, Portable Analyzer, Gold Tester, Spectrometer2229byte
ED6 Plus Liquid-Liquid Extractor: Fully Automated Chemistry Lab Instrument for Multi-Sample Extraction with Advanced Control8202byte

Portable Gas Detector The Gas Leak Detector Is Suitable for The Detection of C2h4 H2 CH3oh C4h10 C2h6o and Other Gases4250byte
Ethylene Oxide Alarm, Industrial Explosion-Proof Gas Leak Detector, Concentration Detector C2h4o Gas Detector3367byte
Quick Fuel Cell Tester LCD Screen Rapid Alcohol Breathalyzer945byte
O2 Auto Detector System 8 Channel Fixed Gas Leak Analyzer Controller2700byte
Exhaust Gas Analyzer Automotive Exhaust Gas Analyzer2840byte

Y09-310 (AC-DC) 28.3 L/Min Battery Operated Laser Particle Counter for Clean Rooms3401byte
Factory Price Shc-300 Alkaline Water Electrolysis Hydrogen Generator for Fid1955byte
Drop Wire FTTH Optical Fiber Cable 1000m/Wood1730byte
Cost-Effective Portable Oil Particle Counter Lubricant Oil Water Content Tester Online Particle Meter8434byte
High Quality Jy-Ecpt3000 Electrophoresis Power Supply with Constant-Voltage for Lab1983byte

Laboratory Acidity Alkalinity Redox Titration Benchtop Digital Automatic Potential Potentiometric Titrator2848byte
Iot Sensor3333byte
Automatic Fluoride Monitoring System for Sewage Treatment Equipment Spectrophotometry1948byte
as-300A Automatic Hall Flowmeter for Metals2041byte
Dlab Brand Laboratory Equipment Mx-T6-S Blood Roller Mixer1411byte

Metallographic Inlay Manual Model Xq-1 Metallurgical Sample Mounting Press3325byte
Alpha-610 Advanced Lab-Grade Automatic Metallographic Grinding and Polishing Machine2947byte
Quick Temperature Measurement Thermocouple for Fast Temperature Readings4468byte
Cheap Price Paper Tube Sampler Immersion Fast Response Sampler for Molten Metal5087byte
Precise Rated Type K 602 604 Measuring Thermocouple Connector Thermocouple4685byte

Factory Manufacturing Customizable Metal Immersion Disposable Iron Sampler4555byte
High Pressure Laboratory Sample Low Price Flexpress Screen Display Vacuum Automatic Metallographic Specimen Mounting Molds and Clamps Press Machine2483byte
Long - Lasting T-35K Type Armored Rapid Temperature Measurement Thermocouple4685byte
Mt-1h Automatic Hydraulic Specimen Precision Metallographic Mounting Equipment Professional Lab-Grade Sample Preparation Machines for Microscopy Analysis2510byte
High Accuracy Industrial Grade 602 604 Temperature Measuring Thermocouple4685byte






Purchasing Request


Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...

  • Professiona Secured Trading Service
  • Verified Business Licenses to Supplier or Manufacturer
  • Welcome to our Global alliance Member