IPDB › China Industry › Instruments & Meters
China, Chinese Non-Standard Supply of Switching Power Supply, Intelligent Switch Test Aging Cabinet1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Test InstrumentEnvironmental Test ChamberIntelligent Switch Test Aging CabinetAging of Power BanksPower Bank Aging Cabinet
Taiyuan Machinery Euqipment(Dongguan) Co., Ltd
Preview:
Product Description Product DescriptionTY-2000 Non-standard supply of switching power supply, intelligent switch test aging cabinetMain functions and characteristics of aging cabinets1. Suitable for intelligent electronic locks, LED drive power supply products2.Real time monitoring of the condition of aged products and accurate screening of defective aging produc ts3. Each tested product is equipped with a status indicator light, with dual indications on the trolley panel and computer monitoring interface4. Computer interface allows real-time viewing of voltage and current data5. Computer program setting aging parameters, which can be set in digital batches7. Aging data can be recorded and stored, and exported for analysis purposes8. The product aging time can be set, and the system will end the aging process in a countdown and automatically cut off the power supply11. The equipment body is equipped with casters and a designated foot cup, making it easy and flexible to move12. Using a single computer to control multiple zones, up to 24 cabinetsItemNameSpecification parameters1Aging cabinet modelTY-20002Appearance of aging equipmentG-type - constant temperature type3DimensionL2000*W700*H1850(mm)4Material/ColorSheet metal paint/gray5Fixed methodCastor wheel+foot cup6Configure the collection moduleEN8C-20007Maximum power ofthe product6V3A8Number of layers4 th floor9Aging per layer810Number of aged products5611Configure acquisition board channels5612Enter ON/OFFhave13Operation control interfacecomputer14Communication PortRS48515IO panel indicator lightLED light indication16Equipment power supplyAC 380V 50HZ 3 phase 4 wires+ground wires17Product power input220-6VDC bus power supply18AC input voltage range switchingnothing19Number ofAC input voltage segments380V20Auxiliary heatinghave21No-load temperature rangeRT +10 °C ~ +100 °C (common temperature +10 °C 65 °C)22Temperature fluctuation≤ ± 1 °C23Temperature uniformity± 3.0 °C (empty Containing a constant temperature test)24Heating timefrom RT to +60 °C takes about 20 minutes (no load)25Inner materialcolor steel plate surface spray treatment26Outer material201# stainless steel plate27Insulation material24K glass rock wool (flame retardant, fireproof)28Controller7-inch HR-U800 intelligent touch-type temperature controller29HeaterFin-type heat pipe nickel-chromium U-type high- efficiency heater30Intake/exhaustEach independent box φ60cm Inlet valve number 1 (adjustable intake air volume), each independentΦ60cm exhaust valve box number 1 (reserve exhaust pipe interface, to facilitate the customer to take the exhaust gas out ofthe room)31Temperature measuring bodyThermal resistance type PT100 sensorMain technical parameters and functions of the acquisition module(2) Introduction to module features*Working with independent power supply, strong anti-interference ability, and stable operation *Adopting the original imported ST brand MCU control, with guaranteed quality*Double ball cooling fan with long service life*The use ofTaiwan KE Dip switch greatly reduces the damage of vulnerable parts*The acquisition module has temperature control speed and temperature protection (OTP) functions, as well as OCP/OVP and other protection features*The SMD components are supplied by well-known suppliers such as TI, YAGEO, and RALEC to ensure the quality of the load*The overcurrent detection resistor adopts precision resistors, with small temperature drift and stable operation at high temperatures*The collection module uses LED indication and monitoring interface dual indication to distinguish between good and bad products, with clear distinction*The collection module is designed by our company, making after-sales maintenance convenient andreliable3.List of main material brands used in the collection moduleItemNameSpecification1Acquisition module modelTY-20002Single channel maximum power6V3A3Single mode rated power/4Number of single module channels8 Communities5Input voltage range0-6VDC6Input current range0.02-3A7Voltage reading accuracy≤3%+/-0.5%FS8Current reading accuracy≤3%+/-0.5%FS9Module supply voltageDC 12V10Static module power consumption≤ 3W11Module temperature drift≤ 100 ppm12Module control modeComputer contact procedures control13Communication methodRS48514Module selfprotection functionOVP, OCP, OPP, OTP Protection Functions15Automatic fault retrieval functionModular autopsy functions1 ,The total width of each layer ofproduct area is 250mm2 ,Each layer of aging rack can age 8 products, a total of 7 layers, and a total of 56 products can be agedDC OUTPUT PORT configuration Client required customized!USB TypeCImage of the acquisition board module (based on the actual object, for referenceonly)Software interface description1. Product monitoring interface, where each point represents each product2. Each monitoring point has four states: green good; Red - defective product; Yellow - power off indication; White - no electricity or not installed; Grey - indicates that the product is not connected to the machine3. The top is the menu operation field; The fields on the right are basic aging information and operation buttonsComputer configuration requirements: Requirements for computer software and hardware when installing aging cabinetsSoftware: It is recommended to use WINDOWS XP (32-bit system) or WINDOWS7 (32-bit system)Hardware: It is recommended to use computers with INTEL CPU, Pentium series or Celeron series oraboveEach aging cabinet control requires an RS232 interface. If only a single aging cabinet needs to be controlled,the motherboard must have at least one RS232 interface (9-pin) when selecting the motherboard. If a single computer needs to control more than 2 computers, the requirement for the computer is that the motherboard must have PCI-E slots (long slots). Generally, PCI conversion cards are 2-port, 4-port, and 8-port, so control the corresponding number of aging cabinets, So there should be corresponding expansion slots (PCI slots), and it is recommended to choose a computer motherboard with more than 2 PCI slots(Note: Free aging monitoring software, communication line 5M. RS232-485 converter)Company Profile:TAIYUAN MACHINERY EQUIPMENT(DONGGUAN)CO.,LTD is the subsidiary of TAIYUAN GROUNP(CHINA)CO.,LTD.The TaiYuan machinery company is located in 'the world factory'Dongguan City, the the Pearl River Delta region of China, adjacent to Hong Kong and Macao.We have over 30 years in producing Chemical, and aviation equipments;Simulated climate testing and Size measuring equipments;Automated production equipments;Food production equipments etc.,those are widely used for scosmetics, food,chemical aviation,biology, pharmaceuticals etc.Especially our independently developed aviation solid propellant mixer and liquid metal, molten salt high-temperature magnetic transmission pump are hot selling and getting so good sales volume in USA, South America,North America, Europe,Rssia,Southeast market etc,Our company has 6000m2 working shop,with lSO, CE European certification and Manufacture License forpressure machines.We have all kinds of technical personnel.resea
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...