IPDB › China Industry › Chemicals
China, Chinese High Quality Ce Standard Roof Filter for Paint Booth Filter1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Synthetic FabricChemical FiberPrimary FilterFilter
Guangdong Jingzhongjing Industrial Painting Equipments Co., Ltd.
Preview:
Product Description Remark: The filter are used for spray booth.It can get good discount if buy together with our spray booth.Put into the container and load with spray booth in the empty space can get free shipping.Pre-Filter (Before Fans) 1. SY-20 Coarse filter cotton (120g/m2) ·Washable and reusable·Low resistance ·Excellent flame retardant ·Flexible ·Economical and practicalApplication: ≥5μm , Filter dust (especially used in the train or the subway, where the place has air-conditioner), pre-filter through air filter programType: pads or rolls sizeMedia: synthetic fiber with gradual density.Washable: about 2-3 timesEN779 class: G2Average arrestance:75%(ASHRAE52.1-1992)EUROVENT4/5 class: EU2DIN53438 Non-flammability Standard: F1Final resistance: (suggested) 100Pa-(max)200PaMax. Dust holding capacity: 430g/m2Temperature resistance: 100oC TypeDimensionsRated air velocity(m/s)Initial pressure drop (Pa)Rated air flow(m2/h)Length(m)Width(m)Thickness(mm)Rolls201/210 ± 21.01836002.SY-30 Coarse filter cotton(120g/m2) ·Washable and reusable ·Low initial resistance ·Large dust holding capacity ·Flexible ·Economical and practicalApplication: ≥5μm, Filter dust , (especially used in the train or the subway, where the place has air-conditioner), pre-filter through air filter programType: supply pads or rolls sizeMedia: synthetic fiber with gradual density, inlet side is blue.Washable: about 4-5 timesEN779 class: G3Average arrestance:88%(ASHRAE52.1-1992)EUROVENT4/5 class: EU3DIN53438 Non-flammability Standard: F1Final resistance: (suggested) 150Pa-250PaMax. Dust holding capacity: 520g/m2Temperature resistance: 100oC TypeDimensionsRated air velocity(m/s)Initial pressure drop (Pa)Rated air flow(m2/h)Length(m)Width(m)Thickness(mm)Rolls201/215 ± 21.52054003. SY-40 Coarse filter cotton(230g/m2) ·Washable and reusable ·Low initial resistance ·Large dust holding capacity ·Flexible ·Economical and practicalApplication: ≥5μm, Filter dust, (used in the placeswhere need washing and filtering),pre-filter through air filter programType: supply pads or rolls sizeMedia: synthetic fiber with gradual densityWashable: about 7-8 timesEN779 class: G4Average arrestance:91%(ASHRAE52.1-1992)EUROVENT4/5 class: EU4DIN53438 Non-flammability Standard: F1Final resistance: (suggested) 200Pa-250PaMax. Dust holding capacity: 620g/m2Temp. resistance: 100oC TypeDimensionRated air velocity(m/s)Initial pressure drop (Pa)Rated air flow(m2/h)Length(m)Width(m)Thickness(mm)Rolls201/220 ± 21.0383600Roof-Filter (Under the air room) 4. SY-560G Ceiling filter (400g/2) ·Low initial resistance ·Large dust holding capacity ·Flexible ·Outlet side with net or cloth mesh to reinforceApplication: capturing 1-10μm particles,especially for the top part of spray booth,prefiltration mesh to reinforce through airfilter system, diffluent equallyType: supply pads or rolls sizeMedia: synthetic fiber with gradual density,surface of inlet side with adhesive treatmentEN779 class: F5Average arrestance:96%(ASHRAE52.1-1992)Average efficiency: 45%-55 %(ASHRAE52.1-1992)EUROVENT4/5 class: EU5DIN53438 Non-flammability Standard: F1Final resistance: (suggested) 400PaMax. Dust holding capacity: 450g/m2Temperature resistance: 100oCInstant temperature: ≤120oC TypeDimensionsRated air velocity(m/s)Initial pressure drop (Pa)Rated air flow(m2/h)Length(m)Width(m)Thickness(mm)Rolls14/211.6/2220.303810805. SY-600G Ceiling filter(600g/2) ?Low initial resistance ?Large dust holding capacity ?Flexible ?Outlet side with net or cloth Application: capturing to particles, especially for the top part of spray booth, prefiltration through air filter program, diffluent equally Type: supply pads or rolls sizeMedia: synthetic fiber with gradual density, fullimregnated with adhesive treatmentEN779 class: F5Average arrestance:96%(ASHRAE52.1-1992)Average efficiency: 45%-55 %(ASHRAE52.1-1992)EUROVENT4/5 class: EU5DIN53438 Non-flammability Standard: F1 Final resistance: (suggested) 400PaMax. Dust holding capacity: 480g/m2Temperature resistance: 100oCInstant temperature: ≤120oC TypeDimensionRated air velocity(m/s)Initial pressure drop (Pa)Rated air flow(m2/h)Length(m)Width(m)Thickness(mm)Rolls14/211.6/2220.2540900Floor-Filter (Under the Grids) 6. PA-50 Paint arrestor(2,50g/ms) ·Low initial resistance ·High separation efficiency ·Different color on inlet and outlet side ·Flexible ·Economical and practicalApplication: used in the spray booth or filter mist in the kitchenType: supply pads or rolls sizeMedia: fiber glass with gradual density, inlet side isgreen,outlet side is whiteEN779 class: G3,G4Average arrestance:93%(ASHRAE52.1-1992)EUROVENT4/5 class: EU3, EU4Average separation efficiency: 95%Final resistance: (suggested) 130Pa-200PaTemperature resistance: 170oC TypeDimensionsRated air velocity(m/s)Initial pressure drop (Pa)Rated air flow(m2/h)Length(m)Width(m)Thickness(mm)Rolls200.8/1/250/602.0107200Remark: All Above filter are use for spray booth.It can get good discount if buy together with our spray booth.Put into the container and load with spray booth in the empty space can get free shipping.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...