China, Chinese Acrel Amc16z-Za Multi Channel Energ Meter Neutral Current 2-63rd Harmonic of Voltage and Current 6 Channels Passive Switch Input1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Meter for ElectricityOther Meters for ElectricityMulti Channel Energy MeterData Center Monitoring Module
ACREL CO., LTD.
Preview:
Product Description Product DescriptionAMC16Z series AC precision power distribution monitoring device is specially designed for data center server power management.The device designed exquisite, can provide A + B 2 incoming and 96 outgoing's electrical parameters, the input and output switch and the state of lightning protection device with real-time monitoring. All alarm threshold of measurement channels can be set in separate. Over-outgoing triggers system acoustooptic warning immediately. Highly integrated monitoring loop is realized in the volume of traditional instruments.Product ParametersType ModelFunction descriptionAMC16Z-ZAMonitor the full power parameters of A+B double-way three-phase AC incoming circuit, 6-way switch state monitoring, 2-way alarmoutput, 2-way leakage monitoring, 1-way temperature and humidity detection, 1-way RS485communication, and phase-sequence detection.AMC16Z-FAMonitor the full power parameters of 24 branches of A+B double-way AC outgoing line, 1-way RS485 communication and phaseadjustment.AMC16Z-KAWet contact, monitoring A+B total 48 branch switch state, 1-way RS485 communication.AMC16Z-KDDry contact, monitoring A+B total 48 branch switch state, 1-way RS485 communication.AMC16Z-FAK24Monitor the full power parameters and switch state of 24 branches of A+B double- way AC outgoing line, 1-way RS485 communicationand phase adjustment.AMC16Z-FAK48Monitor the full power parameters and switch state of 48 branches of A+B double- way AC outgoing line, 1-way RS485 communicationand phase adjustment.AMC16Z-FDK24Monitor the full power parameters and switch state of 24 branches of A+B double-way DC outgoing line, 1-way RS485 communicationand phase adjustment.AMC16Z-FDK48Monitor the full power parameters and switch state of 48 branches of A+B double-way DC outgoing line, 1-way RS485 communicationand phase adjustment.FunctionDescriptionMeasurement(Common)Three-phase AC kWh, kVarh, Active Power, Reactive Power, Current, Voltage, Power Factor, Apparent Power, Frequency, Zero groundvoltage, neutral line currentMeasurement(Power Quality)total harmonic content (THD), 2-63 harmonics, current and voltage unbalance degree, current K coefficient (KF), voltage crestcoefficient (CF), telephone waveform factor (THFF), peak voltage, voltage and current sequence quantityTemp.&HumidityMonitoringTemperature Monitoring Range: -40oC~+99oCHumidity Monitoring Range: 20%~90%Leakage Current2-channel Leakage Current MeasurementAccuracyElectrical Parameter Metering Accuracy: Voltage/current level 0.2, active power/electric energy level 0.5, reactive power/electricenergy level 1Temperature Metering Accuracy: ±1oC; Temperature Metering Accuracy: ±5%CommunicationRS485 Interface (MODBUS-RTU protocol)DO(Switch Output)2-channel DO (Digital Output); 3A 250VAC/3A 30VDCDI(Switch Input)6-channel DI (Digital Input); dry contactParameterDescription&ValueVoltageInputRated Voltage3x220~264Vac L-NReference Frequency45~65HzCurrentInputRated Current3x1(6)A AC (via CTs)PowerSupplySource fromVoltage Input (Voltage signal input for both measurement and power supply)InstallationDIN-rail35mm standard DIN-rail InstallationPhaseWiring3P4W3-phase 4-wireSafetyInsulationAll terminals and the insulation resistance between the conductive pieces not less than 100MΩWithstand voltageA-way voltage and current signal, B-way voltage and current signal, switch output and other ports should meet AC2kV 1min in pairs,the switch input and other ports should meet ac0.5kv 1mim, leakage current should be less than 2mA, no breakdown or flashoverConditionDescription&ValueTemperatureOperating Temperature: -20oC~+55oC; Storage Temperature: -40°C ~+70°CHumidity≤95%RH, no condensation, without corrosive gasAltitude≤ 2000mInstallation InstructionsCertifications
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...