China, Chinese AC Current Transient Waveform Integrator for Current Probe Signal Converter1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
SensorCurrent Sensor1V AC Peak Flexible Sensor Rogowski IntegratorRogowski Coil Transducer Multiscale Converter
ROGOWSKI TECHNOLOGY (SHANGHAI) CO., LTD.
Preview:
Product Description HF High Frequency integrator HF is a High Frequency Rogowski coil integrator, in a compact shield aluminium alloy enclosure, powered directly from the mains.It is providing the measurement of all kinds of waveforms like 3/5μs, 8/20μs,10/350μs,frequencyfrom 100kHz to 1MHz, it also features in direct connection to oscilloscopeWhat does Integrator do?? Rogowski coil output is weak voltage mV signal,HF has ability to amplify and convert it to standard signal which could be catched by multimeter and scope.? Rogowski coil output is proportional to the frequency of the measured current, the signal equalization ensure a linear response on a wide frequency range. TP allows to use coils on different electrical network frequencies, keeping the same output level over the frequencies.? An integrator is essential to equalize and shift by 90° the output signal from the Rogowski coils. It consists of an active electronic circuit with negligible offset and a good linearity.FeatureTP can be combined with any model and size of Y-FCT or FCT Rogowski coils.The available values are: 0-12V peakOn request the input value can be customized according to the application.TP and Rogowski coil is a very flexible system, suitable for high power load analysis, impulsive current monitoring, DC ripple measurement, etc.Due to its specific features, flexible Rogowski coil is an extremely comfortable solution for current measurement and can be used in a number of cases where traditional current transducer is not the adequate solution.Advantage? High read accuracy 2% ? Wide power supply arrange:4-12VDC? 1/5μs,8/20μs,10/350μs waveform restore? Up to 500kA lightning current measurementRelated ProductsH-FCT ApplicationsMeasuring devices, lab instrumentation? Lightning protection? Lightning monitoring? Lightning current measurement? Pulse waveform analysis What is a Rogowski coil?Rogowski coils have been used for the detection and measurement of electric currents for decades. They are based on a simple principle: an "air-cored" coil is placed around the conductor in a toroidal fashion and the magnetic field produced by the current induces a voltage in the coil. The voltage output is proportional to the rate of change of current. This voltage is integrated, thus producing an output proportional to the current.By using precision winding techniques, especially developed for the purpose, the coils are manufactured so that their output is not influenced by the position of the conductor within the toroid, and to reject interference from external magnetic fields caused, for example, from nearby conductors.Basically, a Rogowski coil current measuring system consists of a combination of a coil and conditioning electronics.Rogowski coil current transducers are used for the AC measurement.They can be used in similar circumstances to current transformers but for many applications they have considerable advantages:? Wide dynamic range.? High linearity.? Very useful with large size or awkward shaped conductors or in places with limited access. Thanks to the structure without hard core, the coil can be easily manufactured according to the application or to the available space.? Unlike traditional current transducers, there is no danger from open-circuited secondaries.? They cannot be damaged by large overloads.? They are non-intrusive. They draw no power from the main circuit carrying the current to be measured.? They are also light weighted and in some applications are light enough to be suspended on the conductor being measured.The transducer does not measure direct currents but, unlike a current transformer, it can carry out accurate measurements of AC component even if there is a large superimposed DC component, since there is no iron core causing saturation. This feature is particularly useful for measuring ripple currents for example in battery charging systems.Specification ModelHFRated output1V AC peakMaximum Output(overload)12V AC peak Rated ratio1kA/1V10kA/1V50kA/1VMinimum ratio:1000A/1VRead Accuracy2% typical at 10% to 1000% of rated Current @25oCPhase error≤0.5°Linearity±0.5% of reading(10% to 1000% of range)Minimum Current measurement10% of rated ratioTypical waveform 1/5μs,8/20μs,10/350μsResponse time≤1usPower consumption300mWOutput on 0A (zero drift)≤10mVTemperature drift200ppm/oCWeight160gDimension86*90*29mmPower supply4-12V DC (included 85-265AC to 12V DC adaptor)Operating temperature-20oC to 70oCStorage temperature-30oC to 90oCRelative humidity80% max.without condensationProtection degreeIP20Terminal(Locks type) Input:locked with H-FCT signal cableOutput:BNC female terminal with 2m BNC male terminal cable Power:DC-DC terminal 5.5*2.0mm2 with 85-265VAC adaptor Other requirements, please contact us to OEM.Actual waveform showTest Equipment: 8/20 test waveform Transient current waveform Pulse current waveformAbove is Tektronix 3032 oscilloscope showed.Arc fault currentRectifier current measurementInsulator leakage current measurementMotor overload / short circuit protectionPower grid harmonic monitoring, active power filterGround fault monitoring of large complex conductorsPower fault indicator, transmission line fault diagnosis device, line spacing rangingPower frequency and medium frequency welding machine currentProtection system of medium and high voltage switchgearSecondary side current measurement of calcium carbide furnace and electric furnace transformerCapacitance discharge and lightning current detectionMore current sensor Rogowski coils:?8 High Frequency: H-FCT, ?12 High Voltage 36kV: D-SRC ...Application cases in high frequency pulse welding machine: current up to 1500kADetection coil applicated to Power generation equipment of China's second largest hydroelectric station: current up to 500kARogowski coil application in Draught Fan, lightning current up to 300kAhttps://shpytech.en.made-in-china.com/product/RZsfXICAfYVb/China-High-Voltage-D-Src-36kv-AC-Current-Transducerrogowski-Current-Transducer.htmlhttps://shpytech.en.made-in-china.com/product/rONaSMZGLYVc/China-Nrc-Promotion-Rogowski-Coil-Current-Transducer-Rogowski-Transducer.htmlhttps://shpytech.en.made-in-china.com/product/qZvAEMsJHUWm/China-STP-Built-in-Integrator-Selectable-Rogowski-Coilflexible-AC-Current-Probes.htmlhttps://shpytech.en.made-in-china.com/product/mdOtRPWuHphc/China-A05-High-Quality-Shield-Aluminium-Alloy-Enclosure-5A-Output-Rogowski-Coil-Converter.htmlhttps://shpytech.en.made-in-china.com/product/gdSTRYPJOUcW/China-Remote-Handheld-Digital-Power-Quality-Analyzer-with-TFT-Display.htmlSafety and warning notesIn order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions,please read these instructions thoroughly!Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications.Ensure you get up-to-date technical information that can be found in the latest associated datasheet under Rogowski website.Caution!Risk of dangerIgnoring the warnings can lead to serious injury and/or cause damage!The electric measuring transducer may only be installed and put into operation by qualified personnel that have received an appropriate training,The corresponding national regulations shall be observed during installation and operation of the transducer and any electrical conductor.The transducer shall be used in electric/electronic equipment the respect to applicable standards and safety requirements and in accordance with all the related systems and components manufacturers' operating instructions.Caution!Risk of electrical shockWhen operating the transducer,certain parts of the module may carry hazardous live voltage(e.g.primary conductor).The user shall ensure to take all measures necessary to protect against electrical shock.The transducer is a build-in device containing conducting parts that shall not be accessible after installation.A protective enclosure or additional insulation barrier may be necessary.Installation and maintenance shall be done with the main power supply disconnected except if there are no hazardous live parts in or in close proximity to the system and if the applicable national regulations are fully observed.Safe and trouble-free operation of this transducer can only be guaranteed if transport,storage and installation are carried out correctly and operation and maintenance are carried out with care.WARING!Do not stress the coil by applying any kind of mechanical force(ie.twisting,puncturing,excessive pressure,tight bending,etc.) which will dramatically degrade the device's accuracy.Order codeCoil:Coil ModelCoil diameter (mm)Output ratio and toleranceSignal cable lengthCode:Y-FCTCode:200(Typical rated 500A)Code:350(Typical rated 1500A)Code:510(Typical rated 3kA)Code:800(Typical rated 10kA)Y-FCT code is length.Code:110110mV/kA@50Hz±5%Code:100100mV/kA@50Hz±0.5%Code:8585mV/kA@50Hz±0.5%Code:5050mV/kA@50Hz±0.5%Code:-2mCode:-5mCode:-10mCode:-20mCode:NRCCode:100(Typical rated 1kA)Code:150(Typical rated 3kA)Code:200(Typical rated 6kA)Code:MRCCode:16(Typical rated 100A)Code:24(Typical rated 300A)Code:36(Typical rated 600A)Code:6060mV/kA@50Hz±5%Code:5050mV/kA@50Hz±0.5%Code:SRCCode:50Code:100Code:150Code:360360mV/kA@50Hz±5%Code:333333mV/kA@50Hz±0.5%Code:100100mV/kA@50Hz±0.5%Code:8585mV/kA@50Hz±0.5%Code:5050mV/kA@50Hz±0.5%Other requirement could be OEM Final Code=Coil model+Coil length+Output ratio tolerance+Signal cable length For example: Y-FCT-350-100-2m is Y shape connector,coil length 350mm,output 100mV/kA@50Hz 0.5% tolerance,signal cable length is 2meter.Integrator:IntegratorOutput formOutput valueRated currentPower supplyCode:D1(DIN-RAIL integrator)Code: .1(AC voltage output)Code: .2(DC voltage output) Code: -333(333mV)Code: -1(1V)Code: -5(5V)Code: -600ACode: -1kACode: -3kACode: -6kACode: -12(12V DC)Code: -24(24V DC)Code: .3(4-20mA output)N/ACode:S9(mini integrator)Code: .1(AC voltage output)Code: .2(DC voltage output) Code: -333(333mV)Code: -1(1V)Code: -3(3V)Code: -12(6-12V DC)Code: -24(24V DC)Code:S1(high accuracy integrator)Code: .1(AC voltage output)Code: .2(DC voltage output)Code: -333(333mV)Code: -5(5V)Code: -10(10V)Code: -12(4-12V DC)Code: -24(24V DC)Code: .3(4-20mA output)N/ACode:ATP-01(1A output three phase integrator)N/A(0-1A)N/ACode: -12(12V DC)Code: -24(24V DC)Code:A01(1A output integrator)N/A(0-1A)N/AN/A(85-265V AC DC)Code:A05(5A output integrator)N/A(0-5A)N/AN/A(85-265V AC DC)Code:HF(high frequency integrator)N/A(0-10VAC peak)N/ACode: -1kA(1kA/1V)Code: -10kA(10kA/1V)N/A(4-12V DC)Other requirement could be OEM Final Code=Integrator+Output form+Output value+Rated current+Power supply For example: D1.1-1-500A-12 is D1 integrator,AC voltage output,500A rated,output 1V,power supply 12V DC A01-1kA is A01 integrator,rated 1kA,output 1A,power supply 85-265V AC DC
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...