IPDB › China Industry › Instruments & Meters
China, Chinese Cyclic Voltammetry Instrument Potentiostat Galvanostat Electrochemical Workstation CS150m1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Test InstrumentOther Test InstrumentElectrochemical WorkstationPotentiostat
Wuhan Corrtest Instruments Corp., Ltd.
Preview:
Product Description CS150M Potentiostat/Galvanostat contains a fast digital function generator, high-speed data acquisition circuitry, a potentiostat and a galvanostat. With high performance in stability and accuracy with advanced hardware and well-functioned software, it is the entry model for you. It includes basic methods such as potentiostatic (I-T), CV, LSV, Potentiodynamic (Tafel plot), galvanostaic charge and discharge(GCD), and doesn't include EIS. Applications- Reaction mechanism of Electrosynthesis, electrodeposition (electroplating), anodic oxidation- Electrochemical analysis and sensor; - Corrosion study of metals in water, concrete and soil etc; Fast evaluation of corrosion inhibitor, water stabilizer, coating and cathodic protection efficiency.- New energy materials (Li-ion battery, solar cell, fuel cell, supercapacitors), advanced functional materials, photoelectronic materials- Electrocatalysis field, OER, HER ORR etcSpecifications Support 2-, 3- or 4-electrode systemPotential and current range: AutomaticPotential control range: ±10VCurrent control range: ±2APotential control accuracy: 0.1%×full range±1mVCurrent control accuracy: 0.1%×full rangePotential resolution: 10μV (>100Hz),3μV (<10Hz)Current sensitivity:1pARise time: <1μs (<10mA), <10μs (<2A)Reference electrode input impedance:1012Ω||20pFCurrent range: 2nA~2A, 10 rangesCompliance voltage: ±21VMaximum current output: 2ACV and LSV scan rate: 0.001mV~10,000V/sCA and CC pulse width: 0.0001~65,000sCurrent increment during scan: 1mA@1A/msPotential increment during scan: 0.076mV@1V/msSWV frequency: 0.001~100 kHzDPV and NPV pulse width: 0.0001~1000sAD data acquisition:16bit@1 MHz,20bit@1 kHzDA Resolution:16bit, setup time:1μsMinimum potential increment in CV: 0.075mVLow-pass filters: covering 8-decadeOperating System: Windows 10/11 Interface: USB 2.0Weight / Measurements: 6.5kg, 36.5 x 30.5 x16 cmTechniques - CS150M TechniquesCS150MCS300MCS310MCS350MW/O EISW/O EISWith EISWith EISStable polarizationOpen Circuit Potential (OCP)√√√√Potentiostatic (I-T curve)√√√√Galvanostatic√√√√Potentiodynamic(Tafel plot)√√√√Galvanodynamic√√√√Transient polarizationMulti-Potential Steps√√√√Multi-Current Steps√√√√Potential Stair-Step (VSTEP)√√√√Galvanic Stair-Step (ISTEP)√√√√Chrono methodsChronopotentiometry (CP)√√√√Chronoamperometry (CA)√√√√Chronocoulometry (CC)√√√√VoltammetryCyclic Voltammetry (CV)√√√√Linear Sweep Voltammetry (LSV)(I-V)√√√√Staircase Voltammetry (SCV) # √ √Square wave voltammetry (SWV) # √ √Differential Pulse Voltammetry (DPV)# √ √Normal Pulse Voltammetry (NPV)# √ √Differential Normal Pulse Voltammetry (DNPV)# √ √AC voltammetry (ACV) # √ √2nd Harmonic A.C.Voltammetry (SHACV) √ √AmperometryDifferential Pulse Amperometry (DPA) √ √Double Differential Pulse Amperometry (DDPA) √ √Triple Pulse Amperometry (TPA) √ √Integrated Pulse Amperometric Detection (IPAD) √ √EISPotentiostatic EIS (Nyquist, Bode) √√Galvanostatic EIS √√Potentiostatic EIS (Optional freq.) √√Galvanostatic EIS(Optional freq.) √√Mott-Schottky √√Potentiostatic EIS vs. Time (Single freq.) √√Galvanostatic EIS vs. Time (Single freq.) √√Corrosion testCyclic polarization curve (CPP)√√√√Linear polarization curve (LPR)√√√√Electrochemical Potentiokinetic Reactivation (EPR)√√√√Electrochemical Noise (EN)√√√√Zero resistance Ammeter (ZRA)√√√√Battery testBattery charge and discharge√√√√Galvanostatic charge and discharge (GCD)√√√√Potentiostatic Charging and Discharging(PCD)√√√√Potentiostatic Intermittent Titration Technique(PITT)√√√√Galvanostatic Intermittent Titration Technique(GITT)√√√√TECHNICAL ADVANTAGES1. Polarization curveIt can complete linear polarization curve and Tafel plot measurements. The user can set the anodic reversal current (passivation film breakdown current) of the cyclic polarization curve to determine material's pitting potential and protection potential and evaluate the its susceptibility to intergranular corrosion. The software employs non-linear fitting to analyze polarization curve, and can make fast evaluation of material's anti-corrosion ability and inhibitors.Polarization curve of Ti-based amorphous alloy &stainless steel in 3%NaCl solution2. Voltammetry It can do the following electroanalysis methods: Linear Sweep Voltammetry(LSV), Cyclic Voltammetry(CV).It integrates calculation of peak area, peak current and standard curve analysis.CV of PPy supercapacitor in 0.5 mol/L H2SO4'LSV: mesoporous carbon material in 0.1M KOH3. Electrochemical NoiseWith high-resistance follower and zero-resistance ammeter, it measures the natural potential/current fluctuations in corrosion system. It can be used to study pitting corrosion, galvanic corrosion, crevice corrosion, and stress corrosion cracking etc. Through noise spectrum, we can evaluate the inducement, growth and death of metastable pitting and crack. Based on calculation of noise resistance and pitting index, it can complete localized corrosion monitoring.Electrochemical noise of low-carbon steel in 0.05mol/L Cl-+0.1mol/L NaHCO34. Full floating measurementCS150M workstation uses full-floating working electrode. It can be used for autoclave electrochemical measurements, on-line corrosion monitoring of metallic components under the ground (rebar in concrete, etc.)5. Software development kit (SDK) We are able to provide API functions and development examples, which facilitates some users' requirements for secondary development and self-defined measurements. We can provide .dll file to do the development in Labview etc. SOFTWARE FEATURESCyclic voltammetry CS studio software provides users a versatile smoothing/differential/ integration kit, which can complete the calculation of peak height, peak area and peak potential of CV curves. In CV technique, during the data analysis, there is function of selecting exact cycle(s) to show. You can choose to see a cycle or some cycles as you want. You can also export data or vector graph of an exact cycle or several cycles.Battery Test and analysis: charge & discharge efficiency, capacity, specific capacitance, charge & discharge energy.Tafel plot and corrosion rate CS studio also provides powerful non-linear fitting on Butler-Volmer equation of polarization curve. It can calculate Tafel slope, corrosion current density, limitation current, polarization resistance, corrosion rate. It can also calculate the power spectrum density, noise resistance and noise spectrum resistance based on the electrochemical noise measurements.Real time saving of data: The data can be automatically saved even in case of sudden power off. Combination test: it can facilitate the automation of experiments and save time. With the unique function of combination test, you can choose several techniques, and set the wait time, the start time, and the cycles. Choose the experiments you want to run. Then you can make auto measurement of the set experiments as you want without having to wait in the lab. This function is especially useful if you have multi experiments to run and save your time greatly.Data open: You can open the data files by txt format in notepad directly. Data can also be opened in OriginStandard supply list -Model CS150M potentiostatInstrument host CS150M x1CS studio software x1Power cable x1USB cable x1Cell cable x2Dummy cell(1kΩ||100μF) x1Manual x1Service (the after-sale service is totally free)1. Warranty period: 3 years2. Provide manual, software installation video, and training videos. 3. Provide repair service for free4. Lifetime free software upgrading and technical service
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...