IPDB › China Industry › Instruments & Meters
China, Chinese Stc-8080A+ Refrigeration Automatic Timing Defrosting Intelligent Thermostat1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
HeatingRefrigeration Temperature ControlThermostat Temperature ControllerRefrigerator Temperature ControllerCooling and Heating Thermostat
Kelaimi Ai Technology (Hainan) Co., Ltd.
Preview:
Product DescriptionSpecification Size85*75*34.5MaterialsAnti - flammable ABSSensor wire length 2 meters (including the probe,Weight290gPower supply12V 24V 110-220VAC 50Hz/60HSelf consumption power<3WTemperature Setting5℃-35℃Relay output capacity10A(0.5HP)/220VACAccuracy+1℃(-50℃~70℃)displayLEDHumidity+20%~+85%(No condensate)Ambient temperature0℃~60℃Micro-computerTemperature ControllerInstructions ofSTC-8080A+General:STC-8080A+is a universal temperature controller with singlesensor, specify all the functions as refrigerating, defrosting.alarming when temperature exceeds setting limit.Compressor delay proteclion time is solidified as 3 minutescontroller start up and close according to the solidifiedproportional time when sensor eror, which can be applied tothe industries such as cold storage, refrigerator car, elc.Main functions:To measure, display and control temperatureDafrosting cycle and defrosting time is adjustableAlarm when temperalure exceeds setling temperature jimitvalueCompressor start up delay protectionCompressor work as scheduled timme when sensor errorSpecifications and size:Front panel slze:75mm(length)x 34.5mm(width)Installing hole size:71mm(length) x 29mm(width)Product size: 75mm(lengih) x 34.5mm(width)x85mm(depth)sensor wire length: 2 meters (incuding the probe)Technical parameters:Power supply:220VAC+10%115%,50180HZPower consumption: ≤3WTemperature measuringrange:-50℃-+99Temperature controlling range:-40℃-+50℃Resolution:1tAccuracy:t1Cwhen iemperature -400-+50℃,+2℃aothersRelay capacity of compressor 10A220VACRelay capacity of defroster:10A220VACSensor type: NTc sensorFront panel safe lavel: lP@4Operating temperature:0℃-+60℃CRelalive humidity:20%--85% (No condensate)Storage temperature:-30℃-+75℃0Panel diagram:Key Functions and operation instructions:Check parameters setting value (in the state of non-settingPress On key it display the set maximum value; Press Down key itdisplay the set minimum value, Press "Set" it display defrostcycle; Press "Rst" key it display defrost time .To modify the parameter setting mode:Press"Set" for 3s to enter the parameter adjusting mode.and set indicator light on. LED displays the parametersadjusted last time.Press On or Down to choose desired parameters. After theselection of parameters the value of correspondingparameter is displayed by pressing "Set".Press Set, and On or Down simultaneously to adjust the valueof parameters; Press "Set", and hold on On or Down for morethan 1 second to quickly increase or decrease the parametervalue; Press On or Down to alter other parameters after the settingof one parameter value. Just repeat the above-mentionedsteps.System will save the modified parameter value and back tothe normal working status if pressing the "Rst" key or no keyoperations in 30s.Manual defrosting:?Manual defrosting is allowed when defrosting time valueis not set as "O".Under non-defrosting status, press Down key for 3s to startup the manual defrost.Under defrosting status, press Down key for 3s to stopdefrosting.To restore parameter settingrFirstly, controler checks the parameter setting whenelectrified, Screen display"E1" when finding error, andbuzzer alarm, then Press the "Set" key to restore thedefault value, and system works normally, it is advised toreset the parameter value in such cases.Key function table:Control output:Compressor:Compressor starts up when measuring temperature ishigher than the setting max.temperature value, andcompressor close when the measuring temperature is lowerthan setting min.temperature value. Compressor worksfollowing the cycle as when probe fails: works for 15 minutesand then stops for 30 minutes. After electrified or compressostops,compressor restart-up is allowed after running out ofcompressor protection time.Defrosting;Defrosting starts in any of the folowing status:Controller runs out of the setting defrosting cycle.Under the non-defrosting mode, pressing the "Down" key formore than 3 seconds.Note: Refrigerating output is forbidden during the defrostingp10CeSS.Defrosting stops in any of the following status:Defrosting time is run out of.Under the defrosting mode, pressing the "Down" key for morethan 3 seconds.Another defrosting cyce run again when electrified or whenthe defrosting time used up.Defrosting function is canceledwhen defrosting cyde or defrosting time is set as 0.Manualdefrosting is alowed when defrosting time is not set as 0.Alarm:Exceeding temperature limit alarm:When sensor measuring value is higher than maximumvalue + set alarming temperature value or lower thanminimum value-set alarming temperature value,temperature controller alarms, buzzer works and LED blinks.Alarm will continue until temperature back to normal range.Screen flashes and displays E1 with buzzer alarms if erroroccurs during storage process; Screen flashes and displaysE2 with buzzer alarms when sensor error;LED displays *HH" when measuring temperature is between+99'℃ and 120℃.Note: Pressing any key can manually cancel the alarm soundwhile alarm indicator light display status doesn't change.Descriptions ofIndicator Lights:Menu instruction:Safety rule:Danger:Please strictly distinguish the connections of relay,sensor and power, Make sure the relay is not overload.All the wire connection must be operated under thepower off status.Warning;Prohibit to use the controler under the circumstancessuch as :over moisture, over high temperature, strongelectromagnetic interference, strong corrosion.Notice:Make sure the voltage confirm to the marking on themachine and the power supply steady.It is advised to keep proper distance between sensorleads and power supply wire to avoid possibleinterference.Wiring diagram:Error information:FAQ1. who are we?We are based in Zhejiang, China, start from 2020,sell to Domestic Market(80.00%),North America(10.00%),SoutheastAsia(5.00%),Northern Europe(5.00%). There are total about 11-50 people in our office.2. how can we guarantee quality?Always a pre-production sample before mass production;Always final Inspection before shipment;3.what can you buy from us?Room temperature controller,electric valve,Smart thermostat,Central air-conditioning thermostat,Smart thermostat4. why should you buy from us not from other suppliers?We have a special R & D team, electronic engineers, mechanical designers, can follow up the needs of customers at any time for thedevelopment and production of customized products5. what services can we provide?Accepted Delivery Terms: FOB,CFR,CIF,EXW,FAS,CIP,FCA,CPT,DEQ,DDP,DDU,Express Delivery,DAF,DES;Accepted Payment Currency:USD,CAD,CNY;Accepted Payment Type: T/T,L/C,Credit Card,PayPal,Cash;Language Spoken:English,Chinese,Japanese
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...