Send

Food Packaging Bag

Gift Box & Bag

Industrial Packaging Bag

Logistics Packaging

Machinery for Packaging Supplies

Non Woven Bag

Other Bags & Cases

Package & Conveyance

Package & Printing Service

Packaging Bags

Packaging Materials

Packing Bottle

Packing Machinery

Post-Press Equipment

Pre-Press Equipment

Printing Machinery

Printing Materials

Shopping Bags

Specialized Case & Box

Stencil

Tag & Sign

Tag Gun

Tool Packaging

Watch Box

IPDBChina IndustryInstruments & Meters



China, Chinese Multi-Parameter Flowmeter That Directly Displays Temperature, Pressure, Differential Pressure, Instantaneous Flow Rate and Cumulative Flow Rate on Site1 Industrial Products Supplier Manufacturer Details, price list catalog:

China Industrial Products Supplier Manufacturer List Catalog
« Previous Next »

Meter for Liquid GasFlow MeterPressureDifferential PressureInstantaneous Flow Rate and Cumulative Flow Rate on SiteMulti-Parameter TransmitterSmart Transmitter

Chongqing Hongxing Instrument Co., Ltd.

Preview:

Product Description Model: HJP-seriesMedium range: gas, liquid, steam, gas-liquid mixed mediumNominal diameter: DN15~3000Human connection method: clamp connection, flange connection, pipe connectionAccuracy: ±0.5%Repeatability: ±0.2%Turndown ratio: 10:1Requirements for front and rear straight pipe sections: front 3DN, rear 1DNApplicable range of Reynolds number: 200~10000000B value range: 0.25-0.85Medium temperature range: -200oC~-600oCMedium pressure range≤42MpaMaterial range: CS, 0Cr18Ni9, 316, 316L, HB, HC, and other special materials according to user requirementsFlange standard: American standard, German standard, national standard, and other special standards according to user requirementsfeaturesHigh linearity and good repeatabilityBecause the HJP series porous balance flow sensor has the characteristics of porous symmetrical structure and a large number of test data show that the porous balance flow sensor can balance the flow field, reduce the eddy current, reduce the vibration and signal noise, greatly improve the stability of the flow field, and make the linearity It is 5~10 times higher than the orifice plate, and the repeatability is increased by 54% to 0.15%. From the perspective of its comprehensive performance, the porous orifice flowmeter has high-end flowmeter performance and can be used for trade measurement.Linearity up to ±0.3% at 5:1 turndownLinearity up to ±0.7% at 7:1 turndownLinearity up to ±1.0% at 10:1 turndown overview There are many ways to measure the flow of the medium through the pipeline, but the most widely used and common is the differential pressure flowmeter. It is composed of throttling device and multi-parameter transmitter or differential pressure transmitter together with the secondary table, the throttling device is a differential pressure measurement component, people use it in the pipeline to make the fluid pressure difference, the use of the pressure guide tube before and after the throttling device produced by the differential pressure transfer to the multi-parameter transmitter or differential pressure transmitter, and then input to the secondary instrument, It shows the instantaneous flow or cumulative flow of the fluid in the pipe. Throttling device has a long history and has been standardized both at home and abroad. The throttling device includes standard orifice plate, nozzle, non-standard orifice plate, etc. Can measure the flow of liquid, steam, gas, it is widely used in petroleum, chemical, metallurgy, electric power, light industry and other sectors.  Working principle When the fluid filled with pipe flows through the throttling part in the pipe, the flow rate will form a local contraction at the throttling part, so the flow rate increases, the static pressure decreases, and the pressure difference is generated before and after the throttling part. The larger the fluid flow rate, the larger the pressure difference, so that the flow rate can be measured according to the pressure difference. This measurement method is based on the flow continuity equation (law of conservation of mass) and Bernoulli equation (law of conservation of energy). (The pressure difference depends not only on the flow rate but also on many other factors. For example, when the form of throttling device or the physical properties of the fluid in the pipeline (density, viscosity), the pressure difference produced at the same flow rate is different.) So by measuring the differential pressure, the flow rate can be measured.  characteristic Throttle device structure is easy to copy, simple, firm, stable and reliable performance, long service life, low price. Orifice plate calculation adopts international standard and processing. All single-phase flows can be measured and some miscible flows can be applied. Standard throttling devices can be used without real current calibration. One type orifice plate is simple to install, no pressure tube, can be directly connected to the differential pressure transmitter and pressure transmitter.  Structure type Angular pressure standard orifice plate belongs to standard orifice plate. It is also divided into ring chamber pressure and separate hole Angle pressure. As the pressure is taken directly from both ends of the orifice plate, the measurement accuracy is improved and the minimum length of the straight pipe section required for installation is shortened. It can be used universally.  Flange pressure standard orifice plate: belongs to the standard orifice plate. No matter the diameter of the pipe, the center of the upper and downstream pressure extraction holes are located 1 inch (25.4mm) away from the end face of the hole plate on both sides. This form is widely used in the oil refining system.  Standard orifice plate: It belongs to standard orifice plate. The pressure taking mode is pipeline pressure taking. The center of the upstream pressure taking hole is located at one times the inner diameter of the pipeline in front of the orifice plate, and the center of the downstream pressure taking hole is located at a place half of the inner diameter of the pipeline from the rear end face of the orifice plate.  Nozzles: Nozzles are divided into long neck nozzles, ISA-1932B standard nozzles and non-standard nozzles. Its pressure loss is small, mainly used in power industry main steam flow measurement and flow control detection system.  Embedded (integral) orifice plate: a non-standard orifice plate. For measuring fluid in 10 mm to 50 mm diameters.  Double orifice plate: a non - standard orifice plate. It is composed of two standard orifice plates installed in a straight pipe at a certain distance from each other. According to the direction of the flow beam, the front orifice plate is called the auxiliary orifice plate, and the back orifice plate is called the main orifice plate. The section ratio of the auxiliary orifice plate is larger than that of the main orifice plate m. The two orifice plates form a nozzle similar to that with liquid wall, which is used for the flow measurement of low Reynolds number fluid or high viscosity fluid.  Round hole plate: a non-standard hole plate. It is suitable for the measurement of the fluid flow of dry and dirty, or with bubble precipitation, or containing solid particles, and the measurement accuracy is low.  High pressure lens orifice plate: It belongs to standard orifice plate. High mechanical strength, excellent material, good high temperature and high pressure resistance. Suitable for all kinds of high temperature, high pressure liquid, gas or superheated steam flow measurement with pressure greater than 20MPa.  Venturi: double Venturi is used to measure smoke, air, air volume and other media, it has almost no resistance loss, large differential pressure signal, high pressure sensitivity, stable performance, reliable work, simple structure, convenient maintenance and other advantages, suitable for large flow, large pipe diameter especially rectangular pipe flow measurement, is the ideal device for measuring low velocity large flow volume measurement.  Main technical parameters Accuracy grade :±0.5%, ±1%, ±1.5% Nominal diameter :10mm~DN1000mm According to the national standard GB/T2624-93 design and manufacture Verification according to the national verification regulations JJG 640-94 Pressure method: Angle pressure, flange pressure, D-D/2 pressure Nominal pressure :0.6~32(MPa) Medium under test: liquid, gas, steam, other mixed media Measured medium temperature :-10oC~+450oC Straight pipe length requirements and throttling device installation in accordance with GB/T26224-93 relevant provisions overview HX3052 multi-parameter transmitter is a new type of intelligent transmitter which integrates differential pressure, pressure, temperature transmitter and flow integrator. Display pressure, differential pressure, temperature, instantaneous flow and cumulative flow at the same time. Can replace intelligent differential pressure transmitter, pressure transmitter, temperature transmitter and flow integrator 4 instruments. Easy to install, no need to debug, install can be used. And can automatically calculate the temperature and pressure compensation for gas, steam and other media, and realize the direct display of parameters such as standard flow rate. The multi-parameter transmitter works with 24V power supply and built-in lithium battery. In the case of external 24V power supply, it can provide current 4-20mA(two-wire system) or RS485(four-wire modbus-rtu system) for remote transmission. The multi-parameter transmitter can be directly matched with any differential pressure type standard throttling device (V cone flow sensor, orifyplate flow sensor, elbow flow sensor, nozzle flow sensor, Venturi single flow sensor, Aniuba flow sensor, Weiba flow sensor, Bitoba flow sensor, wedge flow sensor, Delta flow sensor, uniform pitot tube flow sensor, etc.) Used to form a multi-parameter differential pressure flowmeter (V cone flowmeter, orifice flowmeter, variable tube flowmeter, nozzle flowmeter, venturi flowmeter, A Niuba flowmeter, Weiba flowmeter, Bitoba flowmeter, wedge flowmeter, Delta flowmeter, uniform pitot tube flowmeter, etc.). The introduction of multi-parameter transmitter brings a revolution of differential pressure flowmeter, which is more convenient for customers to use. This kind of multi-parameter transmitter has made a major breakthrough in the micro power consumption (built-in lithium battery can be self-powered for 2-3 years) range ratio (up to 1:500) micro differential pressure (10pa-1500pa). Suitable for all differential pressure flow sensors It can be powered by battery and can work for 2-3 years without external power supply on site (no output). Full isolation output super anti-interference design, shielding all interference Power supply 24VDC(4-20mA two-wire system or RS485 communication four-wire system) Built-in temperature and pressure sensor Automatic temperature and pressure compensation for gas and steam The range ratio is 1:2000/1:4000/1:500 Precision class 0.25 Gas can display temperature, pressure, standard flow and other parameters Steam can display temperature, pressure, mass flow and other parameters The flow sensor linearity can be corrected in ten stages Differential pressure can be measured at a minimum of 10Pa Users do not need to do any debugging installation to use high reliability, users do not need to do any maintenance Company profileChongqing Hongxing Instrument Co., Ltd. is a high-tech industrial enterprise specializing in R&D, production, sales, and service of industrial automation instruments. The company has introduced advanced technology from developed countries, combined with its own years of industry experience, developed various automation control instruments and industrial automation process instruments, which have been widely used in metallurgy, chemical industry, electric power, light Industrial, thermal power, machinery, hydraulic, boiler, paper, pharmaceutical, and other industries.     The company adheres to the "people-oriented, talent-based" principle of employment, and provides various learning and further education opportunities for the growth of employees. Combine the development of the enterprise with the career planning of employees, fully mobilize the enthusiasm of employees, and create a good working atmosphere within the enterprise that is united, persistent, and enterprising.    The company was established to operate the enterprise with the belief of building a century-old store. The company will continue to adhere to this concept, work hand in hand with the majority of users, and make its own contribution to the modernization of industrial enterprises.    The company adheres to the corporate culture of "Hundreds of rivers and seas can be regrettable, and unity of purpose is stronger than gold"; the business strategy is "honesty and trustworthiness, creating a win-win situation"; "high-quality products, excellent service" is an eternal policy. Create a new field of instrumentation

Link supplier or manufacturer »

Instruments & Meters: Multi-Parameter Flowmeter That Directly Displays Temperature, Pressure, Differential Pressure, Instantaneous Flow Rate and Cumulative Flow Rate on Site
Inscinstech Protein Purification System (Unique AutoPure300) Protein Purification Techniques1603byte
ID200*650 Preparative Purify HPLC System1844byte
Fps-100c Single Channel Automatic Peptide Synthesizer1323byte
Inscinstech Lab Instrument Automatic Large Scale Oligonucleotide Synthesizer (Unique AutoOligo25) for The Rapid Synthesis of 10~100μ Mol Nucleic Acid Samples648byte
ID1400*500mm Auto Acrylic Column Column, Bed Lenght 500mm1439byte

ID600mm Purify HPLC System for Natural Plant1537byte
Inscinstech Automatic Large Scale Oligonucleotide Synthesizer (Unique AutoOligo100) for The Rapid Synthesis of 50 μ Mol-9 Mmol Nucleic Acid Samples640byte
Factory Price HPLC High Performance Liquid Chromatography with Isocratic And Gradient System2545byte
Chromatographic Columns USP L1 L8 L11 L10 L Ods Cn C18 C8 Normal Phase / Reverse Phase HPLC Column4416byte
Inscinstech Lab Instrument Protein Purification System (Unique AutoPure150-L1) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP822byte

50dac Preparative Purify HPLC System2241byte
High Efficiency One Stop Solution Chromatograph Machine HPLC Systems High Performance Liquid HPLC Chromatography2545byte
Laboratory High Performance Liquid Chromatography Machine HPLC Chromatography LC-W100A2771byte
LC Laboratory High Performance Liquid Chromatography HPLC with UV Detector for Food Analysis7365byte
100ml Fplc Chromatography for Cetuximab1701byte

Inscinstech Ion Chromatography Protein Purification System (Unique AutoPure25-L1) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP811byte
Biobase HPLC High Performance Liquid Chromatography System Gas Chromatograph5402byte
Biobase Eclassical 3100 Laboratory High Performance Liquid Chromatography System for Laboratory HPLC1278byte
Mass Spectrometer Gas Chromatograph with Fid Detector4942byte
Dw-Gc1120 Economic Gc System Gas Chromatography Fid Tcd Ecd Npd Lab Gas Chromatograph Machine3011byte

High Accuracy Transformer Oil Gas Analyzers Price Dissolved Gas Analysis Equipment GC MS Insulating Oil Gas Chromatograph3258byte
SCITEK Gas Chromatograph Self-Diagnostic System Chromatograph With Seamless PC Control3341byte
Explosion Proof Real-Time Industrial Online Process Analyzer Industrial Online Gas Chromatograph4030byte
Double Beam UV-Vis Spectrophotometer / Spectroscopy Instrument1546byte
2025 RoHS Directive Detection Edxrf Energy Dispersive X-ray Fluorescence Spectrometer2432byte

Gas Chromatograph Mass Spectrometer Gc-Ms4084byte
Laboratory High Performance Liquid Chromatography HPLC with UV Detector for Food Analysis952byte
Inscinstech Protein Purification System Lab Instrument (Unique AutoPure100-L2) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP1569byte
1000ml Ss Pump for Ion Chromatography Pump1448byte
Gc112A Lab Gas Chromatograph Analysis Instrument2874byte

Alva SPD620 Laboratory Sample Pretreatment Digestion Instrument with Metal Heating Module, Chemistry Lab Instrument7790byte
China Factory High Efficiency Kjeldahl Digestion Furnace for Lab Use2011byte
High Precision High Frequency Infrared Carbon Sulfur Analyzer for Alloy Plant5415byte
Carbon Silicon Tester for Foundries Is Used for Pre-Furnace Scarbon Silicondetection of Gray Cast Iron Ductile Cast Iron Foundry Molten Iron Testing Equipment3289byte
Unparalleled Accuracy in Carbon Sulfur Testing with Our Superior Technology Xrf ACP Aas Manufacture6697byte

Aurispec P3 Xrf, Portable Analyzer, Gold Tester, Spectrometer1348byte
Automatic Fat Analyzer SD-P6s for Measuring Fats and Other Compounds Using The Soxhlet Extraction Principle8780byte
Sequential Inductively Coupled Plasma Emission Spectrometer-Icp-Oes/Icp-AES 5% off1756byte
Automatic Kjeldahl Nitrogen Analyzer for Food Crops and Feeds2445byte
High Precision Portable Chlorophyll Meter3412byte

High Precision and Speed with Mining Steel Carbon Sulfur Analyzer6697byte
Digital Oxygen Nitrogen Hydrogen Analyzer for The Determination of Steel1896byte
Aurispec B6t, Benchtop Xrf, Coating Thickness Analyzer, Element Analyzer, Soil, Spectrometer2421byte
Casting Furnace Front Carbon and Silicon Analyzer Automatic Analysis and Automatic Printing5945byte
Fd6800 Fiber Analyzer: Fully Automated Chemistry Elemental Analyzer for Sensitive Detection of CF, Adf, Ndf, Cellulose, and Lignin8082byte

Nanbei Crude Protein Analysis Automatic Kjeldahl Nitrogen Analyzer5041byte
Drawell Portable Xrf Gold Tester Handheld Xrf Mineral Analyzer X-ray Fluorescence Spectrometer2331byte
CS995 High-Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral Coal3201byte
Handheld Smart Mini Poct Automated Blood Gas and Electrolyte Analyzer Electrode Method Blood Analyzer for Hospital Use (SG1)1327byte
Hand-Held Pesticide Residue Meter for Food Safety Meter4150byte

Xrf Sulfur Analyzer X-ray Sulfur Analzyer 5% off1089byte
Desktop Liquid Security Detector Liquid Trace Detector695byte
High Quality Single Flame Atomic Absorption Spectrometer for Lab4823byte
Innovate High-Frequency Infrared Carbon & Sulphur Analyzer5536byte
Carbon Silicon Analyzer for Molten Iron Fast Foundry Thermal Analysis System Cup Sampling Furnace QC Testing Carbon Equivalent Measurement on-Site Liquid Metal5549byte

Full Automatic High Frequency Laboratory Equipment Analysis Instrument Testing Machine Metal Detector Chemistry Analyzer Metal Infrared Carbon Sulfur Analyzer6669byte
Semi-Auto Kjeldahl Protein Analyzer From Factory2538byte
High-Precision Kjeldahl Nitrogen Protein Measurement Equipment for Labs3768byte
Aurispec H3 Xrf, Portable Analyzer, Gold Tester, Spectrometer2229byte
ED6 Plus Liquid-Liquid Extractor: Fully Automated Chemistry Lab Instrument for Multi-Sample Extraction with Advanced Control8202byte

Portable Gas Detector The Gas Leak Detector Is Suitable for The Detection of C2h4 H2 CH3oh C4h10 C2h6o and Other Gases4250byte
Ethylene Oxide Alarm, Industrial Explosion-Proof Gas Leak Detector, Concentration Detector C2h4o Gas Detector3367byte
Quick Fuel Cell Tester LCD Screen Rapid Alcohol Breathalyzer945byte
O2 Auto Detector System 8 Channel Fixed Gas Leak Analyzer Controller2700byte
Exhaust Gas Analyzer Automotive Exhaust Gas Analyzer2840byte

Y09-310 (AC-DC) 28.3 L/Min Battery Operated Laser Particle Counter for Clean Rooms3401byte
Factory Price Shc-300 Alkaline Water Electrolysis Hydrogen Generator for Fid1955byte
Drop Wire FTTH Optical Fiber Cable 1000m/Wood1730byte
Cost-Effective Portable Oil Particle Counter Lubricant Oil Water Content Tester Online Particle Meter8434byte
High Quality Jy-Ecpt3000 Electrophoresis Power Supply with Constant-Voltage for Lab1983byte

Laboratory Acidity Alkalinity Redox Titration Benchtop Digital Automatic Potential Potentiometric Titrator2848byte
Iot Sensor3333byte
Automatic Fluoride Monitoring System for Sewage Treatment Equipment Spectrophotometry1948byte
as-300A Automatic Hall Flowmeter for Metals2041byte
Dlab Brand Laboratory Equipment Mx-T6-S Blood Roller Mixer1411byte

Metallographic Inlay Manual Model Xq-1 Metallurgical Sample Mounting Press3325byte
Alpha-610 Advanced Lab-Grade Automatic Metallographic Grinding and Polishing Machine2947byte
Quick Temperature Measurement Thermocouple for Fast Temperature Readings4468byte
Cheap Price Paper Tube Sampler Immersion Fast Response Sampler for Molten Metal5087byte
Precise Rated Type K 602 604 Measuring Thermocouple Connector Thermocouple4685byte

Factory Manufacturing Customizable Metal Immersion Disposable Iron Sampler4555byte
High Pressure Laboratory Sample Low Price Flexpress Screen Display Vacuum Automatic Metallographic Specimen Mounting Molds and Clamps Press Machine2483byte
Long - Lasting T-35K Type Armored Rapid Temperature Measurement Thermocouple4685byte
Mt-1h Automatic Hydraulic Specimen Precision Metallographic Mounting Equipment Professional Lab-Grade Sample Preparation Machines for Microscopy Analysis2510byte
High Accuracy Industrial Grade 602 604 Temperature Measuring Thermocouple4685byte






Purchasing Request


Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...

  • Professiona Secured Trading Service
  • Verified Business Licenses to Supplier or Manufacturer
  • Welcome to our Global alliance Member