IPDB › China Industry › Instruments & Meters
China, Chinese Original and Upgraded Industrial Applications Yokogawa Bt200 Field Communicator1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Electronic InstrumentCalibratorCommunicatorField Communicator
Kerui (Weifang) Automation Equipment Co., Ltd.
Preview:
Product Description Product DescriptionThe Yokogawa BT200 Field Communicator is a versatile, handheld device designed to streamline the configuration, diagnostics, and maintenance of field instruments in industrial automation environments. As a critical tool for technicians and engineers, it supports communication with HART and FOUNDATION Fieldbus (FF) devices, enabling seamless integration into modern process control systems. The BT200 combines portability with robust functionality, offering an intuitive user interface that simplifies complex tasks such as parameter adjustments, real-time monitoring, and troubleshooting. Its compatibility with a wide range of field instruments-including pressure transmitters, temperature sensors, flow meters, and valve positioners-ensures broad applicability across industries like oil and gas, chemical processing, power generation, and water treatment. Built to withstand harsh field conditions, the BT200 features a rugged design with an IP54 rating for dust and water resistance, along with a long-lasting battery that supports extended operation. The device also supports USB and Bluetooth connectivity, allowing efficient data transfer and remote control capabilities. By providing reliable communication and advanced diagnostic features, the BT200 enhances operational efficiency, reduces downtime, and supports proactive maintenance strategies in industrial settings. The BT200 excels in its ability to bridge the gap between legacy HART devices and modern FF systems, making it a future-proof investment for industries undergoing digital transformation. Equipped with a high-contrast LCD screen and a user-friendly menu structure, the device enables even novice users to perform tasks like loop testing, device calibration, and firmware updates with minimal training. Its dual-mode functionality allows simultaneous communication with HART devices while maintaining the 4-20 mA analog signal, ensuring uninterrupted process control during maintenance. For FF networks, the BT200 acts as a portable link active device (LAD), enabling direct access to field devices for configuration and diagnostics without disrupting the control network. Advanced features include waveform analysis for valve diagnostics, event logging for historical data review, and customizable templates for rapid device setup. The BT200 also supports Yokogawa's Device Description (DD) and Common File Format (CFF) libraries, ensuring compatibility with thousands of devices from multiple vendors. Security is prioritized through password protection and role-based access control, aligning with industry standards for cybersecurity. Additionally, the BT200's lightweight design and ergonomic grip enhance usability during prolonged field operations. With regular firmware updates and global technical support from Yokogawa, the BT200 remains a trusted tool for optimizing instrument performance, ensuring compliance with safety and regulatory requirements, and driving operational excellence in dynamic industrial environments. Installation InstructionsProcedure NameDescriptionTools NeededPrecautionsUnboxing & InspectionRemove BT200 from packaging. Inspect for physical damage. Verify contents against user manual.NoneHandle carefully. Report damage immediately.Battery InstallationInsert 4 AA alkaline batteries into the compartment. Ensure correct polarity.AA batteriesDo not use rechargeable/non-alkaline batteries.Power OnPress and hold POWER button for 2 seconds until display lights up.NoneConfirm battery voltage ≥5.2V. Replace if low.Connection PreparationIdentify HART device's communication terminals or test points.HART-compatible deviceEnsure device is in safe operational state.Cable ConnectionConnect BT200 test leads: red to (+) terminal, black to (-) terminal.BT200 test lead set (TL100)Verify HART loop impedance: 250-1,100Ω.Loop Power CheckConfirm loop voltage ≤30V DC. Use BT200's voltage measurement function.Digital multimeter (optional)Do not connect to >30V circuits.Communication EstablishmentSelect "Online" mode from main menu. Wait for HART communication indicator.NoneKeep leads away from high-voltage sources.Device IdentificationNavigate to [Device] > [Identify]. Confirm device tag matches field instrument.NoneVerify HART revision compatibility (5-7).Parameter ConfigurationUse arrow keys to select parameters. Press ENTER to edit values.NoneRecord original settings before modification.Range SettingAccess [Setup] > [Range]. Input LRV/URV values.Press STORE to confirm.NoneConfirm sensor limits with process requirements.Damping AdjustmentNavigate to [Parameters] > [Damping]. Set time constant (0-100 sec).NoneHigher values smooth noise but delay response.Output CalibrationSelect [Calibration] > [Output]. Follow on-screen current trimming instructions.Current source (optional)Perform only with proper authorization.Sensor TrimChoose [Calibration] > [Sensor Trim]. Execute zero/span adjustments per process conditions.Reference standardUse certified calibration equipment.Function TestForce output 4-20mA signals via [Test] menu. Verify field instrument response.MultimeterNotify operations before testing live systems.Data StorageSave configuration to BT200's internal memory (up to 20 devices).NoneRegularly export data to SD card via expansion slot.Communication TerminationPress ESC to exit online mode. Wait for HART indicator () to disappear.NoneNever disconnect during active communication.Cable DisconnectionRemove test leads in reverse order: black first, then red.NoneWipe terminals clean after disconnection.Power OffHold POWER button for 3 seconds until display turns off.NoneRemove batteries if storing >1 month.Maintenance ModeAccess [Maintenance] menu for loop test, self-diagnosis, or firmware updates.YFGW510 Field Wireless GatewayBackup configurations before firmware updates.Environmental ConsiderationsOperate within specifications: -20°C to +55°C, <85% RH non-condensing.NoneAvoid explosive atmospheres unless BT200 is intrinsically safe certified.Packaging & ShippingCompany ProfileCustomer PhotosFAQQ: How long will you give me the reply?A: We will reply to you as soon as we see the information Q: What is the delivery time?A:The products in stock will be shipped after receiving the payment, and the products thatneed to be ordered are subject to the factory time. Q: How about your package?A: Do not worry about the package, we have rich experience in packing. Q: How about the payment terms?A:You can choose T/T. Q: What is the MOQ?A:1PC. Q: Can l get a lower price if l order large quantities?A: Yes, cheaper prices with more bigger size orders. Q:After sales and warranty?A: We provide one year warranty lifetime technical support services.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...