IPDB › China Industry › Instruments & Meters
China, Chinese High-Precision TA2100 Wideband Power Calibrator for Accurate Measurements1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Electronic InstrumentCalibratorsingle phase power calibratordc power calibrator
Tunkia Co., Ltd.
Preview:
Product Description TA2100 wide frequency power calibrator 1. SummaryTA2100 Is a wide range, high precision, high stability broadband power calibrator, the instrument can output DC voltage, current and power, and has a dual voltage output mode, suitable for calibration power analyzer, AC / DC power meter, voltmeter, ammeter and other electrical measuring instruments. 2. Product featuresStandard Source of AC / DC Voltage: 0.3 V ~ 1020 VStandard Source of AC / DC Current: 0.5 mA ~ 20.5 AStandard Source of Auxiliary Voltage: 2.5 mV ~ 5.5 VSine Wave Frequency: 5 Hz ~ 100 kHzPower Accuracy: Class 0.05Phase-Shifted OutputWideband Power OutputA variety of quantity and value output modeCross-guide amplifier (optional)3. Main applications☆ Calibration power analyzer (medium to low precision)The accuracy is Class 0.05, using the standard source method to calibrate the medium and low precision (Class 0.2 and below) power analyzer.The direct output of the maximum 20.5A, can output an current of 50A or 100A. ☆ Calibration power analyzer (medium to high precision)TA2100 matches TA3100 wide frequency power measurement standard with accuracy of 0.015%.Use the standard meter method to calibrate the power analyzer with medium and high precision (Class0.05 and below).4. Main technical specifications4.1 AC / DC Voltage OutputRangeResolving PowerVoltage Output RangeOutput Frequency RangeMaximum Load Current3 V10 μV0.30000 V ~ 3.30000 VDC, 5 Hz ~ 100 kHz50 mA10 V100 μV1.0000 V ~ 11.0000 VDC, 5 Hz ~ 100 kHz50 mA30 V100 μV3.0000 V ~ 33.0000 VDC, 5 Hz ~ 100 kHz50 mA100 V1 mV10.000 V ~ 110.000 VDC, 45 Hz ~ 100 kHz50 mA300 V1 mV30.000 V ~ 330.000 VDC, 45 Hz ~ 100 kHz50 mA600 V1 mV60.000 V ~ 660.000 VDC, 45 Hz ~ 100 kHz20 mA1000 V10 mV100.00 V ~ 1020.00 VDC, 45 Hz ~ 10 kHz20 mA RangeMeasurement Uncertainty at different frequencies (Hz) (k=2) @ (23°C ± 5°C), (ppm * reading + ppm * range)DC5~4545~1k1k~10k10k~20k20k~50k50k~100k3 V120+80300+200120+80300+200500+300600+4001000+50010 V120+80300+200120+80300+200500+300600+4001000+50030 V120+80300+200120+80300+200500+300600+4001000+500100 V120+80-120+80300+200500+300600+4001000+500300 V120+80-120+80300+200500+300600+4001000+500600 V120+80-120+80300+200500+300600+4001000+5001000 V120+80-120+80300+200---Range switching: manual or automatic shiftProtection function: short-circuit protection, overload protection, overheat protection 4.2 AC / DC Current OutputRangeResolving PowerCurrent Output RangeOutput Frequency RangeMaximum Load Voltage5 mA10 nA0.50000 mA ~ 5.50000 mADC, 5 Hz ~ 100 kHz7 V10 mA100 nA1.0000 mA ~ 11.0000 mADC, 5 Hz ~ 100 kHz7 V25 mA100 nA2.5000 mA ~ 27.5000 mADC, 5 Hz ~ 100 kHz7 V50 mA100 nA5.0000 mA ~ 55.0000 mADC, 5 Hz ~ 100 kHz7 V100 mA1 μA10.000 mA ~ 110.000 mADC, 5 Hz ~ 100 kHz7 V200 mA1 μA20.000 mA ~ 220.000 mADC, 5 Hz ~ 100 kHz6 V500 mA1 μA50.000 mA ~ 550.000 mADC, 5 Hz ~ 100 kHz6 V1 A10 μA0.10000 A ~ 1.10000 ADC, 5 Hz ~ 100 kHz6 V2.5 A10 μA0.25000 A ~ 2.75000 ADC, 5 Hz ~ 100 kHz6 V5 A10 μA0.50000 A ~ 11.0000 ADC, 5 Hz ~ 100 kHz6 V10 A100 μA1.0000 A ~ 11.0000 ADC, 5 Hz ~ 100 kHz6 V20 A100 μA2.0000 A ~ 20.5000 ADC, 5 Hz ~ 100 kHz6 V RangeMeasurement Uncertainty at different frequencies (Hz) (k=2) @ (23°C ± 5°C), (ppm * reading + ppm * range)DC5~4545~1k1k~10k10k~20k20k~50k50k~100k5 mA120+80300+200120+80300+200600+4001000+5002k + 1k10 mA120+80300+200120+80300+200600+4001000+5002k + 1k25 mA120+80300+200120+80300+200600+4001000+5002k + 1k50 mA120+80300+200120+80300+200600+4001000+5002k + 1k100 mA120+80300+200120+80300+200600+4001000+5002k + 1k200 mA120+80300+200120+80300+200600+4001000+5002k + 1k500 mA120+80300+200120+80300+200600+4001000+5002k + 1k1 A120+80300+200120+80300+200600+4001000+5002k + 1k2.5 A120+80300+200120+80300+200600+4001000+5002k + 1k5 A120+80300+200120+80300+200600+4001000+5002k + 1k10 A120+80300+200120+80300+200600+4001000+5002k + 1k20 A120+80300+200120+80300+200600+4001000+5002k + 1kRange switch: manual or automatic shift; open circuit protection, overload protection, overheating protection4.3 Auxiliary Voltage OutputRangeResolving PowerVoltage Output RangeOutput Frequency RangeMaximum Load Current25 mV100 nV2.5000 mV ~ 27.5000 mVDC, 5 Hz ~ 100 kHz10 mA50 mV100 nV5.0000 mV ~ 55.0000 mVDC, 5 Hz ~ 100 kHz10 mA100 mV1 μV10.000 mV ~ 110.000 mVDC, 5 Hz ~ 100 kHz10 mA250 mV1 μV25.000 mV ~ 275.000 mVDC, 5 Hz ~ 100 kHz10 mA500 mV1 μV50.000 mV ~ 550.000 mVDC, 5 Hz ~ 100 kHz10 mA1 V10 μV0.10000 V ~ 1.10000 VDC, 5 Hz ~ 100 kHz10 mA2.5 V10 μV0.25000 V ~ 2.75000 VDC, 5 Hz ~ 100 kHz10 mA5 V10 μV0.50000 V ~ 5.50000 VDC, 5 Hz ~ 100 kHz10 mA RangeMeasurement Uncertainty at different frequencies (Hz) (k=2) @ (23°C ± 5°C), (ppm * reading + ppm * range)DC5~4545~1k1k~10k10k~20k20k~50k50k~100k25 mV150+200350+250150+200350+250600+4001000+5001200+80050 mV150+200350+250150+200350+250600+4001000+5001200+800100 mV150+200350+250150+200350+250600+4001000+5001200+800250 mV150+200350+250150+200350+250600+4001000+5001200+800500 mV120+80300+200120+80300+200500+300600+4001000+5001 V120+80300+200120+80300+200500+300600+4001000+5002.5 V120+80300+200120+80300+200500+300600+4001000+5005 V120+80300+200120+80300+200500+300600+4001000+500Range switching: manual or automatic shiftWiring mode: BNC plugProtection function: short-circuit protection, overload protection, overheat protectionNote: This output is especially suitable for the sensor small signal input of the power analyzer 4.4 FrequencyAdjustable rangeResolving PowerAnnual Measurement Uncertainty (k=2) @ (23°C ± 5°C)5.000 0 Hz ≤ F ≤ 99.999 9 Hz0.000 1 Hz0.01%100.000 Hz ≤ F ≤ 999.999 Hz0.001 Hz0.01%1.000 00 kHz ≤ F ≤ 9.999 99 kHz0.01 Hz0.01%10.000 0 kHz ≤ F ≤ 99.999 9 kHz0.1 Hz0.01%100.000 kHz1 Hz0.01% 4.5 PhasePhase Position[1][2]Annual Measurement Uncertainty (k=2) @ (23°C ± 5°C)5~45Hz45~1kHz1k~10kHz10k~20kHz20k~50kHz50k~100kHzφU -I0.05°0.02°0.05°0.1°0.2°0.5°φU -AUX0.05°0.02°0.05°0.1°0.2°0.5°Note [1]: Adjustment range: 0.000° ~ 359.999°Note [2]: Resolution: 0.001°Phase Position(φ )Power Factor(λ )The Active Power Uncertainty Component caused by the Phase Uncertainty[3]5~45Hz45~1kHz1k~10kHz10k~20kHz20k~50kHz50k~100kHz0°1.000000.000%0.000%0.000%0.000%0.001%0.004%10°0.984810.015%0.006%0.015%0.031%0.062%0.158%20°0.939690.032%0.013%0.032%0.064%0.128%0.321%30°0.866030.050%0.020%0.050%0.101%0.202%0.508%40°0.766040.073%0.029%0.073%0.147%0.294%0.736%50°0.642790.104%0.042%0.104%0.208%0.417%1.044%60°0.500000.151%0.060%0.151%0.302%0.605%1.515%70°0.342020.240%0.096%0.240%0.480%0.960%2.401%80°0.173650.495%0.198%0.495%0.990%1.980%4.953%90°0.00000------Note [3]: Calculation formula: 4.6 AC / DC Power OutputQuantity Range CombinationMeasurement Uncertainty at different frequencies (Hz) (k=2) @ (23°C ± 5°C), (% * power output)[1]DC5~4545~1k1k~10k10k~20k20k~50k50k~100kVoltage and Current Output (U & I) @ (λ =1)(3 V … 30 V) &(5 mA … 20 A)0.030.070.030.070.130.180.34(100 V … 600 V) &(5 mA … 20 A)0.03-0.030.070.130.180.341000 V &(5 mA … 20 A)0.03-0.030.07---Dual Voltage Output (U & AUX) @ (λ =1)(3 V … 30 V) &(25 mV … 250 mV)0.040.080.040.080.130.180.25(3 V … 30 V) &(500 mV … 5 V)0.030.070.030.070.130.180.25(100 V … 600 V) &(25 mV … 250 mV)0.04-0.040.080.130.180.25(100 V … 600 V) &(500 mV … 5 V)0.03-0.030.070.130.180.251000 V &(25 mV … 250 mV)0.04-0.040.08---1000 V &(500 mV … 5 V)0.03-0.030.07---Note [1]: AC / DC power output range (virtual load): 0.15 mW ~ 20.91 kW Note [2]: Power factor adjustment range: -1 ~ 0 ~ + 1, resolution: 0.000 01Note [3]: Power uncertainty calculation formula under other power factors: voltage and current output mode, dual voltage output mode, which: the voltage measurement uncertainty, the current measurement uncertainty, the auxiliary voltage measurement uncertainty, and the measurement uncertainty caused by the power factor. 5. General Technical SpecificationsPower Supply VoltageAC (220±22) V ,(50±2) HzPreheating Time2 times from the last preheating time, up to 30 minutes.Temperature PerformanceOperating temperature: 0°C~40°CCalibration temperature: 18°C~28°CStorage temperature: -20°C~70°CHumidity PerformanceWorking Humidity: <80% @ 30°C, <70% @ 40°CStorage humidity: (20%~80%) R · H, no condensationAbove Sea Class<3000 mCommunication InterfaceRS232×1,USB×1,LAN×1Company Profile
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...