IPDB › China Industry › Instruments & Meters
China, Chinese Laboratory Industrial pH Orp Conductivty Do Ion Sensor Probe Electrode1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Analysis InstrumentpH MeterpH ElectrodeOrp Electrode
Shanghai Total Industrial Co., Ltd.
Preview:
Product Description PH Combined Electrode with Glass BodyNote: Difference between the two models is the reference cell electrolyte. 65-IP is with solution form and can be refilled. 65-IIP is in gel form which last life time, not need to refill.Model65-IP65-IIPMeasuring Range0 - 14 pHTemperature Range0 - 60 °CZero point value7 +/- 1 pHJunctionCeramicReference CellAg/Agcl, KCL solution refillableAg/Agcl, KCL gelSizedia.12 x length 140 mmPlugBNC + 1 m cable SR211 Glass pH ElectrodeRange: 0~14pHMaterial: Lead-free glassJunction: ceramicReference electrode: long-life reference systemElectrolyte: 3M KClDimension: dia. 12mm * 120mmGlass membrane shape: hemisphericConnector: BNC/ 1m wireCharacteristics and application: Traditional laboratory electrode with BNC connector.Normal use, used for scientific research and quality control. typemeasure rangeapplicable temperatureapplication (it can be add temperature compensation element according to client's need.)E-201BNC + 1m cable0~14pH0~60°CThe crust of PC be able to endure hit, gelatin KC1 electrolytic liquid dispense with complementarity ,in order laboratory and locale general use. *(For PH-8414/ORP-8414, PH-2601, 2602, 2603)E-201C/E-210CBNC + 1m cable0~14pH0~60°CThe crust of PC be able to endure hit, it can supplement electrolytic liquid, in order laboratory and locale general use, superior testing accuracy.E201W PH0~14pH0~60°C *(For PH-016, 016A,PHS-3C)E201W ORP0~±1999mv0~60°C Temperature electrode (for PH meters)E-0101 (for PH-0101)typespecificationapplicable temperatureapplicationE201WM PHDia.14×length 85mm BNCMeasuringRange: 0.00~14.00PHResolution:0.01PHOperatingTemperature: 0°C~50°CAutomaticTemperature Compensation (ATC): 0°C~50°CConnection: BNC socket0~50°C *(For PHT-026, 027, 028, PH-025,PH-02636, PH-02736, PH-0253,PH-025M, PH-025N)E201WM ORPDia.14×length 85mm BNCMeasuring Range: 0 ~ ±1999mVResolution: 1mVAccuracy: ±0.1% F·S±1 digitConnection: 300cm cable with BNC socketOperating Temperature: 0°C~50°C ATCWeight: 41g0~50°C*(For PHT-027, 028)E201WM ConductivityDia.14×length 85mm BNCMeasuring Range: 0~19.99ms/cm, 0~1999us/cmResolution: 1us, 0.1mSAccuracy: ±1.5%+2 digitsConnection: with BNC socketOperating Temperature: 0°C~50°C ATCK=1Weight: 41g0~50°C*(For PHT-026, 027, 028, PH-02636, PH-02736)typespecificationapplicable temperatureapplication201DH PH165mm×26mm×26mmMeasuringRange: 0.00~14.00PHResolution:0.01PHOperatingTemperature: 0°C~50°CAutomaticTemperature Compensation (ATC): 0°C~50°CConnection: BNC socket0~50°C *(For Online controller)Note: Waterproof, Suitable for Aquarium.201DH ORP165mm×26mm×26mm BNCMeasuring Range: 0 ~ ±1999mVResolution: 1mVAccuracy: ±0.1% F·S±1 digitConnection: 300cm cable with BNC socketOperating Temperature: 0°C~50°C ATCWeight: 41g0~50°C *(For Online controller)Note: Waterproof, Suitable for Aquarium.typespecificationapplicable temperatureapplication208DH Conductivity electrode165mm×26mm×26mm BNC (or cut-off ends)Measuring Range: 0~1999us/cm, 0~199.9mSResolution: 1us, 0.1mSAccuracy: ±1.5%+2 digitsConnection: with BNC socketOperating Temperature: 0°C~50°C ATCK=1Weight: 41g0~50°C *(For CD-208, CD-308)Note: Waterproof, Suitable for Aquar modelPH rangeResolution°CMPaconnectMΩ(25°C)Zero electricity(PH)Theory slope %Use rangeCT-1001sewage0~14±0.01PH0~500.6cable≤2507±0.5>95Environment -protection sewage online checkCT-1001water0~14±0.01PH0~500.6cable≤807±0.5>95High purify waterProducts: CT-1001 PH electrode using international advanced solid dielectric and a large area of PTFE liquid interface, clogging, easy to maintain Reference long-distance dispersal routes, greatly extending electrode life in harsh environments The PH electrode made of high quality low-noise cable, allows the model output greater than 40 meters in length, no interference High accuracy, fast response, good repeatability Online PH detection are widely used in medicine, chemical industry, environmental protection, electroplating and other industriesPH electrode Features: PPS / PC shell, the upper and lower 3/4NPT pipe thread, easy installation, no maintenance No need to supplement the dielectric, little maintenance Correct operation and long service life PH electrode with similar electrode interchangeable abroadPH electrode technology Data:ModelCT-1001Temperature (o C)0~50°CConnection formCable (shielded cable)Zero potentiometer (PH)7±0.5PH range0 ~ 14Withstanding pressure (MPa)0.6Internal resistanceMΩ(25oC)250Theoretical percentageslope%>95Terminal BlocksBNC head, Pin-type inserts, Y-piece insertsOverall connection3/4 inch outer thread Size188*31mm Installation: PH electrode installation: flow-through, sunk, flanges, pipes type.PH electrode ordering guide: PH electrode and instrument cable plug: BNC connector, PIN connector, Y blade connector (please indicate when you order) Electrode cable length: 5 meters standard, can be customized according to user requirementsProducts: CT-1001C PH electrode using international advanced solid dielectric and a large area of PTFE liquid interface, clogging, easy to maintain Reference long-distance dispersal routes, greatly extending electrode life in harsh environments The PH electrode made of high quality low-noise cable, allows the model output greater than 40 meters in length, no interference High accuracy, fast response, good repeatability Online PH detection are widely used in medicine, chemical industry, environmental protection, electroplating and other industriesPH electrode Features: PPS / PC shell, the upper and lower 3/4NPT pipe thread, easy installation, no maintenance No need to supplement the dielectric, little maintenance Correct operation and long service life PH electrode with similar electrode interchangeable abroadPH electrode technology Data:ModelCT-1001CTemperature (o C)0~50°CTemperature compensationYesConnection formCable (shielded cable)Zero potentiometer (PH)7±0.5PH range0 ~ 14Resolution±0.01PHWithstanding pressure (MPa)0.6Internal resistanceMΩ(25oC)250Theoretical percentageslope%>95Terminal BlocksBNC head, Y-piece insertsOverall connection3/4 inch outer thread Size188*31mm Installation: PH electrode installation: flow-through, sunk, flanges, pipes type.PH electrode ordering guide: PH electrode and instrument cable plug: BNC connector, Y blade connector (please indicate when you order) Electrode cable length: 10 meters standard, can be customized according to user requirements.CT-1002 High temperature Glass type PH electrode The industry PH electrode adopt specific glass, electropolar sense velamen and gelation electrolyte salt. It can meet international standards with the express correspondence and good stability.Performance Features1. Convenient and don't need to add electrolyte2. Gelation electrolyte salt can effectively prevent from Electrode poisoning. e.g.: S2-, CN-3. Annular polyethylene solution can counteract stain. So continued-online detection is supported.4. Different sensitive membrane electrode can be applied for different kinds of PH measurement. And it has lower electrode resistance, express correspondence and good stability.Use Soap1. The electrode can work with various types of ph meter.2. The electrode adopts connector way with the 3/4 inches standard screw thread. 3. The electrode can work for 1 year normally. But the life of the electrode will be reduced if there is a poor environment or an improper maintenance.ParametermodelPHrangeResolution°CMPaconnectMΩ(25°C)Zero electricity (PH)Theory slope %Use rangeCT-1002sewage0~14±0.01PH0~900.4cable≤2507±0.5>95Environment -protection sewageonline checkCT-1002water0~14±0.01PH0~900.4cable≤807±0.5>95High purify waterNote: temperature compensation resistance choice: PT1000, PT100, PT50, 10K, 20K etc.Installation: PH electrode installation: flow-through, sunk, flanges, pipes type.PH electrode ordering guide: PH electrode and instrument cable plug: BNC connector, Y blade connector (please indicate when you order) Electrode cable length: 5 meters standard, can be customized according to user requirements.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...