IPDB › China Industry › Instruments & Meters
China, Chinese Inert Atmosphere Lab Glove Vacuum Box for Lithium Battery1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Test InstrumentEnvironmental Test ChamberLab Glove BoxLab Vacuum Glove Box
XIAMEN TOB NEW ENERGY TECHNOLOGY CO., LTD.
Preview:
Product Description Inert Atmosphere Lab Glove Vacuum Box For Lithium Battery1.Model Super(1220/750/900)Single station, single operation, integrated with a single column purification unit, PLC touch screen operation control, vacuum pump, bracket, a closed box, with operating surface tilt and detachable safety glass front window. Under normal conditions, namely the 20oC constant temperature, a standard atmosphere, inert gas 99.999%, water and oxygen index less than 1 ppm. 2.Technology parameters ItemParameterGlove boxBoxBox size: (L*W*H)=1220×750×900mmBox material: stainless steel 304, thickness 3mmInner surface: stainless steel wire drawing treatmentOutside surface: paint, whiteFront windowTilt windows, transparent tempered safety glass, thickness 8 mmGlove portsThe material is polyoxymethylene, O-ring seal, self-lubricating performance, easy to maintain, and good sealing performanceGlovesButyl rubber, thickness 0.4mm, diameter 8", length 32"Filter:0.3 microns, a gas inlet and a gas outletShelfStainless steel, Adjustable heightLightingLED lights, installed in front of each glass windowConnectorStandby interface 3pcs, DN 40 KF, Power interface 1pc (220V)Bigger transitive cabinChamberSize: diameter 360mm, length 600mmMaterial: 304 stainless steelSurface: inner surface wire drawing process, outer surface painting (white)AccessarySliding tray: 304 stainless steelDoor: double door, anodized aluminum material, thickness 10mm, vertical operation, with lifting mechanismPressure gauge: Analog displayControlSolenoid valve touch screen automatic operationSmaller transitive cabinChamberSize: diameter 150mm, length 300mm (100mm length into the glove box)Material: 304 stainless steelSurface: inner: wire drawing process, outer: painting (white)AccessaryStandard configuration: small cabin trayDoor: double door, thread lockPressure gauge: Analog displayControlManual valve manual operationGas purification circulation systemPurification columnFunction: gas sealed, remove water, remove oxygen Container material: 304 stainless steelPurification materials: copper catalyst: 5kg, molecular sieve: 5 kgPurification capacity: oxygen: 60L, water: 2KgWater and oxygen indicators: less than 1ppmCirculatory systemWorking gas: nitrogen, argon, heliumRecycling capacity: integrated fan flow 90m3 / h, install frequency conversionRegenerationOperation: PLC automatically controls the regeneration processRegeneration gas: working gas mixed with hydrogen gas, (hydrogen 5-10%)Vacuum pump8m3 / h, rotary vane pump, with oil mist filter, air vibration controlValvesMain valve: DN 40 KF, electrically operated angle valveControl valve: electromagnetic integrated valve Control SystemFunctionIncluding self-diagnosis, power-off self-starting characteristics, with pressure control and adaptive functionAutomatic control, cycle control, password protectionPressure controlControl box, transition chamber pressure, cabinet working pressure +/- 10mbar can be set freely, beyond +/- 12mbar system automatic protectionPedalControl the box pressure, easy to operate boost and buckDisplay systemUsing Siemens PLC touch screen, display running status, box pressure, system records etcVacuum system controlVacuum pump, can be manually or through the PLC to start, flow 8m3/h, vacuum of the transition chamber, and keep the box pressure balance, vacuum pump limit vacuum ≤ 2x10-1paOptional componentsWater analyzerMeasuring range: 0~500ppm platinum electrode structure (P2O5 structure, can reach the factory level by simple cleaning), a wide range of applications, especially for users such as lithium battery manufacturing and metal organic, can be restored to the initial state through the cleaning and regeneration process, avoiding one-time pollution and scrapping The problem.Oxygen analyzerMeasuring range: 0 ~ 1000ppmThe use of ZrO2 sensor, to avoid the fuel cell life is short, and avoid the problem of it can not be exposed in the airOrganic solvent adsorberSize: diameter 237mm, height 407mm, thickness 0.3mmMaterial: stainless steel 304,Fill with 9kg of activated carbon. Connected with the main circulation pipeline, the circulating gas can first flow through the organic solvent adsorber device to absorb the organic solvent in the gas. Manual ball valve control can quickly change the adsorption material without destroying the circulating atmosphere.Remove HF deviceDimensions: diameter 237mm, height 407mm, thickness 0.3mmMaterial: 304 stainless steelFill with 9kg alumina particles. Connected to the main circulation pipeline, the circulating gas can first flow through the HF removal device to absorb HF in the gas. Manual ball valve control, can quickly change the adsorption material without destroying the circulating atmosphere
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...