IPDB › China Industry › Instruments & Meters
China, Chinese Xrf Metal Analyzer Gold Spectrometer Alloy Mineral Tester Spectrophotometer1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Analysis InstrumentElement AnalyzerHand Held Metal AnalyzerMetal Analyzer
Jinan Cyeeyo Instruments Co., Ltd.
Preview:
Product Description Xrf Metal Analyzer Gold Spectrometer Alloy Mineral Tester Spectrophotometer CY-A650 X fluorescence analyzer is a good spectrum instrument developed for many years, specially for non-ferrous metals, ferrous metals, Mineral processing and smelting, geological industry customized a high-end analysis instrument. technical specifications Measure the range of elementsFrom sodium (Na) to uranium (U)Measure the concentration range concentration rangeppm-99.99% ( Different elements, the analysis scope is different)Measure object statusPowder, solid, liquidElemental analysis abilityDozens of elements ranging from sodium (Na) to uranium (U) are measured at onceoptimum resolution129eV±5eVBest analysis accuracyRSD≤0.1%( National standard sample)parsing timeSingle test time is adjustableRefrigeration methodElectric refrigeration, no consumablesLarge sample cavity size400mm x 340mm x 80mmVacuum sample cavity sizeφ100mm×h75mmAppearance size700mmx510 mmx336mmworking power supplyAC 220V ±5V ,50Hzwork environmentIndoor temperature 15~30 oC ; relative humidity 80% (no dew condensation)The weight of the machine56KGPerformance characteristics Analysis efficiencyFast speed, good accuracy, high efficiency, using the self-developed analysis software can complete the simultaneous and accurate analysis of dozens of elements from 11 sodium (Na) to 92 uranium (U) in 1-120 secondsFunctional advantages1. Appearance design: beautiful, durable, multiple safety protection mode.2. Collimation filter system:collimator+multi-combination filter, software automatically switch, to meet various test applications.3. The self-developed SES signal processing system (digital multi-channel) can effectively improve the peak back ratio and make the measurement more accurate.4. Multi-dimensional heat dissipation system: optimize the integrated heat dissipation design, improve the heat dissipation performance of the whole machine, and ensure the operation safety of X-ray source5. Radiation safety system: multiple radiation prevention leakage prevention design, radiation protection level belongs to the highest level of similar products6. Vacuum system: select the vacuum system, optimize the test environment, improve the analysis accuracy of light elements such as magnesium, aluminum, silicon and phosphorus and sulfur, and greatly expand the analysis capability of A-650 analyzer.7. Unique movement temperature monitoring technology, to ensure the safe and reliable operation of the radiation source, effectively extend its service life, reduce the service cost.Hardware advantageImport of the whole set of core parts1. Detector: Original American Amptek silicon drift SDD probe with minimum resolution as low as 129eV ± 5eV, excellent energy linear and energy resolution, peak back ratio.2. X-ray tube: maximum power 50W, tube voltage 5-50KV, tube current 0-1000uA; long-life X-ray tube.3. High voltage power supply: maximum power 50 W, voltage 0-50 KV, current 0-1000uA.8-Hour Stability of 0.05%.4. Signal processor: using imported signal processor, adapted to high resolution and high counting rate, self-adjusted magnification, maximum channel number: 4096.Software advantageThe Chinese version of the X-fluorescent analysis software developed by Danaher and our company, the software fusion experience, theoretical alpha coefficient method, linear fitting, quadratic curve, intensity correction, content correction and other analytical methods, comprehensive guarantee Accuracy of test data.location of apparatus System standard1. Digital Multichannel Type SDD detector2. X-ray source3. high voltage source4. SNR electronic circuit system5. Optical road enhancement system6. 8 Collimation + 5 filter7. The Digital Multichannel Analyzer8. pumped vacuum system9. Brand-name inkjet printer10. Brand computer11. X fluorescence full-element analysis software12. Sample cup, fuse13. Spectral voltage power supply (optional)System selection1. Spectral special grinder (optional)2. Spectra special melting sample machine (optional)3. Spectral special Powder machine (optional)4. Melt sample platinum crucible (optional)5. Special chip press for spectrometer (optional)Product applicationThe CY-A650 spectrometer can analyze the following samples and elements (oxide): Sample categoryElements categoryS inter / pellet oreTFe ,Si ,Ca , Mg ,Al , Mn ,Ti , P ,S , K ,V etcHigh furnace slag/converter slagTFe ,Si ,Ca , Mg ,Al , Mn ,Ti , P ,S , K ,V etcrefining slagAl , Ca ,Si , Mg , Fe ,Ti etcPre-melt slagCa , Mg ,Al ,Si , Fe , P ,S etccalcium aluminateSi ,Al , Fe , Ca , Mg etccalcium ferriteFe ,Al , Ca ,Si ,S , P etcManganese slagMn , Fe , P ,S ,Si ,Al , Ca etcIron concentrate powder / iron oreTFe ,Si ,Ca , Mg ,Al , Mn ,Ti , P ,S , K ,V etcHematite / magnetiteT Fe , K , Na ,S , P ,Al ,Si , Mg ,Ca , Mn ,Zn ,Cu ,Ti etclead zinc orePb ,Zn ,Ag , Cu ,Sn , Fe ,S ,Cd , Mo ,As etcmanganese oreMn ,Si , P ,S ,Al ,Ti , K ,Zn ,Ca , Mg etcTitanium oreTi , Mn , Fe ,Si , P ,S ,Al , K ,Zn ,Ca ,V , Cu , Mg etccopper mineMn , Fe ,S ,Cu , Pb ,As ,Au , Cd ,Zn ,Ag , Mg etc chromiteFe , P ,S ,Al ,Cr ,Ca , Mg ,Si etcrefractoryHigh silicon clay S i ,Al , Fe , Ca , Mg , K , Na ,S , P etcHigh aluminum alum soil Al , Fe ,Ti , Na , K , Mn ,Ca , Mg, Si , P etcHigh magnesium magnesium sand Mg ,Ca ,Si ,Al , Fe etcboulewhite fused alumina Al , Na ,Si , Ca , Fe etcbrown alumina Al ,Si ,Ti , Fe etcblack corundum Al ,Si ,Ti , Fe etcpink fused alumina Al , Na ,Cr , Fe etcZirconia Zr ,Si ,Al , Na , Fe ,Ti , Ca , Mg , K etcCement raw material / clinkerSi ,Al , Fe , Ca , Mg , K , Na , S ,Cl-etclimestoneS , P ,Al ,Si , Fe ,Ti , Mn ,Sr ,Ca , Mg etcdolomiteS , P ,Al ,Si , K , Na , Fe ,Ti , Mn ,Sr , Ca , Mg etctabular sparSi , Ca , Fe ,Al ,Ti , Mg etctaxoiteMg ,Si , K , Na ,Ca , Fe ,Ti , Mn ,Al ,S , P etcmulliteAl ,Si , Fe ,Ti ,Ca , Mg , K , Na etcMagnesium aluminumapexAl , Mg ,Ca ,Si , Na , Fe etccannCa , P ,S ,Si ,Al , Fe , Mg ,Ti , Mn , K , Na etcgangueSi ,Al , Fe , Ca , Mg ,Ti , P ,V etcquartz sandZr ,Si , Fe , P ,S ,Al ,Ti etcrutileTi ,S , P , Fe , Nb ,Ta ,Cr ,Sn etcgarnetCa , Mg , Fe , Mn ,Al ,Cr etcpig ironSi , Mn , P ,S ,Ti , Cr ,V etchigh-manganese pigironFe , Mn , P ,S ,Si , Cr etcferro-silicon alloyAl ,Si , Ca , Na , Mg , P ,S , Fe ,Cr , Mn , Cu , Ba etcsilicomanganeseMn , P ,S ,Si etcsilicozirconiumSi , Ca ,Al , Ba ,ZR , Mn etcSilicon aluminum barium calciumSi ,Al , Ba ,Ca etcSilicon barium calcium / silicon calcium / silicon bariumSi , Ba ,Ca , Ba , Fe etcferro-nickelNi , Mn ,Si ,Cu ,Co ,Cr ,V ,S , P etcferrovanadiumV , Mn ,Si , P ,S etcchromium ironCr ,Si , P ,S ,V , Fe , Mn ,Ti etcferromanganeseMn ,Si , P ,S , Cr , Ni ,V , Fe etcferrocolumbiumNb ,Al ,Si ,S , P etcSmelter leadPb ,Sb ,Sn , Bi , Fe ,Si ,Ca ,S etcelectrolytic manganeseMn ,S , P etc drossSn , Fe ,Si , Ca etcvanadium slagV , Mn ,Cr ,Ti ,Ca ,Si etcglassSi ,Al , Fe , Ca , Mg , K , Na etcFly ash (thermal power plant)Si ,Al , Fe , Ca ,Ti , Mg , K , Na ,S , Mn etcGrouting agent (rare earth magnesium silicon alloy)Mg , RE ,Si ,Ca ,Al etcinoculantSi , Ba ,Ca ,Al etcvermiculizerMg , Re , Ca ,Si ,Al etccovering agentCa ,Si , Mg ,Al , Fe etcPipe die powderSi , Ca ,Al , Ba ,ZR , Mn etcdregs removerCa ,Si ,Al etcagglomerated fluxSi ,Ti ,Ca , Mg ,Al , Mn ,S , P etcbrazing powderTi ,Zr , Ni ,Cu ,Ag ,Zn ,Sn ,Si , Mn , Ni , Cr , P etcaluminaSi , Fe ,Ca , Mg etcIndustrial siliconAl , Ca , Fe ,Ti , Mn , Ni etcSCR denitration catalystCa , Na , K ,As ,W ,V etcSoil heavy metalPb ,As, Cd , Hg, Cu, Ni ,Zn,Cr etc Measure the range of elementsFrom sodium (Na) to uranium (U)Measure the concentration range concentration rangeppm-99.99% ( Different elements, the analysis scope is different)Measure object statusPowder, solid, liquidElemental analysis abilityDozens of elements ranging from sodium (Na) to uranium (U) are measured at onceoptimum resolution129eV±5eVBest analysis accuracyRSD≤0.1%( National standard sample)parsing timeSingle test time is adjustableRefrigeration methodElectric refrigeration, no consumablesLarge sample cavity size400mm x 340mm x 80mmVacuum sample cavity sizeφ100mm×h75mmAppearance size700mmx510 mmx336mmworking power supplyAC 220V ±5V ,50Hzwork environmentIndoor temperature 15~30 oC ; relative humidity 80% (no dew condensation)The weight of the machine56KG Packaging & ShippingOur AdvantagesFAQ
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...