IPDB › China Industry › Instruments & Meters
China, Chinese Multichannel Potentiostat Galvanostat 4-Channel Electrochemical Workstation CS310X (Option A)1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Analysis InstrumentOther Analysis InstrumentsMultichannel PotentiostatPotentiostat
Wuhan Corrtest Instruments Corp., Ltd.
Preview:
Product Description Corrtest Multichannel potentiostat/ galvanostat/EIS is a versatile instrument offering 8 slots. Multichannel potentiostat/ galvanostat model CS310X (Option A) is the 4-channel potentiostat. 4 slots are occupied with potentiostat boards. The rest 4 slots are unoccupied for future adding potentiostat board(s). Option A equals that you have 4 sets independent single-channel potentiostat/galvanostat in one chassis. EIS module (10μHz~1MHz) is equipped in only ONE channel. Each channel potential control range is ±10V, current control range ±1A, can meet experiment requirement for most people.Full floating module and electrical isolation design guarantee each channel is totally independent, which ensures accurate data and efficient simultaneous measurements. 4-channel potentiostatApplication- Reaction mechanism of Electrosynthesis, electrodeposition (electroplating), anodic oxidation.- Electrochemical analysis, electro-catalysis, sensor; - New energy materials, advanced functional materials, photoelectronic materials;- Corrosion study of metals in water, concrete and soil etc;- Fast evaluation of corrosion inhibitor, water stabilizer, coating and cathodic protection efficiency.There are 4 basic options for CS310X. Option A: 4-channel with EIS in one channel Option B: 4-channel, with EIS in all four channelsOption C: 8-channel, with EIS in one channel Option D: 8-channel, with EIS in all 8 channelsThe number of the channel and EIS modules can be cusomized. Lower model can be upgraded to higher one by adding more potentiostat boards on current deviceEIS module can be upgraded online. ModelCS310X OptionsOption AOption BOption COption DNumber of channels 4488Max. current on each channel±1A ±1A±1A±1APotential range on each channel±10V±10V±10V±10VEIS (10μHz~1MHz)Included on 1 channel onlyIncluded on all 4 channelsIncluded on 1 channel onlyIncluded on all 8 channelsStandard supplyInstrument host CS310X-1 setCS studio6 software, Power cable - 1 piece, Ethernet cable - 1 pieceElectrode cable -8 pcs Dummy cell, Manual Instrument host CS310X-1 setCS studio6 software, Power cable - 1 piece, Ethernet cable - 1 pieceElectrode cable -16 pcs Dummy cell, Manual Specifications Specifications Number of channels with boards: 4Channel insulation resistance: >100MΩCommunication: EthernetLower-pass filter: covering 8-decadePotential control range: ±10VConstant current control range: ±1A on each channelPotential accuracy: 0.1%×full range±1mV Current accuracy: 0.1%×full rangePotential resolution:10μV(>100Hz), 3μV(<10Hz)Current resolution: 1pAPotential rise time: <1μs(<10mA), <10μs(<2A)Current range: 2nA ~1A, 10 rangesReference electrode input impedance: 1012Ω||20pFMaximum current output: ±1ACompliance voltage: ±21VCurrent increment during scan: 1mA @1A/msCV and LSV scan rate: 0.001mV~10000V/sPotential increment during scan: 0.076mV@1V/msCA and CC pulse width: 0.0001~65000sDPV and NPV pulse width: 0.0001~1000sSWV frequency:0.001~100KHzCV minimum potential increment: 0.075mVAD data acquisition:16bit@1MHz,20bit @1kHzIMP frequency:10μHz~1MHzDA resolution:16bit, setup time:1μsCurrent and potential range: automatic Operating System requirements: Windows 10/11Weight: 12.5 Kg Dimensions: 40*40*14cm Electrochemical Impedance Spectroscopy (EIS)Signal generatorFrequency range: 10μHz~1MHzAC signal amplitude: 1mV~2500mV Frequency accuracy: 0.005%Signal resolution: 0.1mV RMSDDS output impedance: 50ΩDC Bias: -10V~+10VWave distortion: <1%Waveform: sine wave, triangular wave, square waveScan mode: Logarithmic/linear, increase/decreaseSignal analyzerMaximum integral time:106 cycles or 105sMeasurement delay:0~105SMinimum integral time:10ms or the longest time of a cycleDC offset compensationPotential compensation range: -10V~+10VCurrent compensation range: -1A~+1ABandwidth adjustment: automatic and manual, 8-decade frequency range TechniquesStable polarizationOpen Circuit Potential (OCP)Potentiostatic (I-T curve)GalvanostaticPotentiodynamic (Tafel plot)Galvanodynamic (DGP)Transient PolarizationMulti Potential StepsMulti Current StepsPotential Stair-Step (VSTEP)Galvanic Stair-Step (ISTEP)Chrono MethodChronopotentiometry (CP)Chronoamperametry (CA)Chronocaulometry (CC)VoltammetryLinear Sweep Voltammetry (LSV)Cylic Voltammetry (CV)Staircase Voltammetry (SCV) #Square Wave Voltammetry (SWV) #Differential Pulse Voltammetry (DPV) #Normal Pulse Voltammetry (NPV)#Differential Normal Pulse Voltammetry (DNPV) #AC Voltammetry (ACV) #2nd harmonic AC Voltammetry (SHACV)Fourier Transform AC Voltammetry (FTACV)Battery testBattery Charge and DischargeGalvanostatic Charge and Discharge (GCD)Potentiostatic Charging and Discharging(PCD)Potentiostatic Intermittent Titration Technique (PITT)Galvanostatic Intermittent Titration Technique (GITT)Electrochemical Impedance Spectroscopy (EIS) (included on ONE channel only)Potentiostatic EIS (Nyquist, Bode)Galvanostatic EISPotentiostatic EIS (Optional freq.)Galvanostatic EIS(Optional freq.)Mott-SchottkyPotentiostatic EIS vs. Time (Single freq.)Galvanostatic EIS vs. Time (Single freq.)Corrosion MeasurementsCyclic polarization curve (CPP)Linear polarization curve (LPR)Electrochemical Potentiokinetic Reactivation (EPR)Electrochemical Noise (EN)Zero resistance Ammeter (ZRA)AmperometricDifferential Pulse Amperometry (DPA)Double Differential Pulse Amperometry (DDPA)Triple Pulse Amperometry (TPA)Integrated Pulse Amperometric Detection (IPAD)# There is corresponding stripping techniqueSimultaneous Measurements You can choose a same electrochemical technique in every channel. As is shown in below picture, we let 4 channels do EIS. In each channel, the user can also choose different experiments. Set the parameters for experiment in each channel and start simultaneous measurements. As is shown in the below picture, EIS, galvanostatic charge and discharge, CV, and polarization curve tests are conducted at the same time.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...