IPDB › China Industry › Instruments & Meters
China, Chinese TD1050 Calibration Apparatus for Clamp Meters1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Electronic InstrumentCalibratorclamp meter calibrationfluke clamp meter calibration
Tunkia Co., Ltd.
Preview:
Product Description TD1050 Calibration Apparatus for Clamp Meters 1. SummaryTD1050 is a calibration apparatus for multifunctional clamp meters, which integrates functions such as AC/DC high current standard source, AC/DC voltage standard source, and resistance standard source, and also has AC/DC power output function, which can meet the calibration needs of multifunctional clamp meters with different accuracy levels.2. FeaturesAccuracy: Class 0.05DC current: 10 mA ~ 1050 A(2100 A is optional)AC current output: 10 mA ~ 1020 A(2050 A is optional)DC voltage output(optional): 20 mV ~ 1100 VAC voltage output(optional): 1 V ~ 825 VFrequency: 40 Hz ~ 400 HzDC resistance output(optional): 10 Ω ~ 11 MΩTwo thickness copper ringsAC/DC power output(optional)3. Application ☆ Calibrate Clamp Meter by Single-turn MethodDCI output: 10 mA~1050 A(2100 A is optional)ACI output: 10 mA~1020 A(2050 A is optional), 40 Hz ~ 400 HzCalibrate AC\DC clamp ammeters☆ Calibrate Clamp Power Meters(optional)Integrates AC\DC current and voltage standard source, the U-I phase can be adjusted, which is suitable for calibrating clamp power meters. ☆Calibrate Multi-function Clamp Meters(optional)DCV output: 20 mV ~ 1100VACV output: 1 V ~ 825 V, 40 Hz ~ 400 HzRES output range: 10 Ω ~ 11 MΩCalibrate AC/DC voltmeter and DC resistance meter 4. Panel FeaturesItemDescription1Current Source, Output AC\DC current. 2Copper Ring 1, I≤110 A.3Copper Ring 2, I>100 A.4Workbench, used to settle the device.5Operate Panel, adjust electric parameter of the device.6Voltage Output terminals7Resistance Output terminals8Operate Panel terminal, connected to the control panel.9RS232 Interface,.10Power Switch11E-Stop, Used to stop the power supply in an emergency 5. Characteristics☆ Convenient TraceabilityCalibrate the AC\DC current source through accessing the standard ammeter(TH0630 or TH0530)to the current loop. ☆ Wide Output Range 6. Specifications6.1 DC CurrentCopper RingRangeResolutionOutput RangeMax LoadRing 1100 mA1 μA10.000 mA ~ 110.000 mA8 V300 mA1 μA30.000 mA ~ 330.000 mA8 V1 A10 μA0.10000 A ~ 1.10000 A8 V3 A10 μA0.30000 A ~ 3.30000 A8 V10 A100 μA1.0000 A ~ 11.0000 A8 V30 A100 μA3.0000 A ~ 33.0000 A8 V100 A1 mA10.000 A ~ 110.000 A8 VRing 2250 A1 mA20.000 A ~ 275.000 A8 V500 A1 mA50.000 A ~ 550.000 A8 V1000 A10 mA100.00 A ~ 1050.00 A8 V2000 A [1]10 mA200.00 A ~ 2100.00 A8 VNote[1]: 2000 A is Optional RangeStability (±%/min)Accuracy, ±(ppm*RD+ppm*RG) [2]Ripple Factor (%)100 mA0.01300 + 100<0.5300 mA0.01300 + 100< 0.51 A0.01300 + 100< 0.53 A0.01300 + 100< 0.510 A0.01300 + 100< 0.530 A0.01300 + 100< 0.5100 A0.01300 + 100< 0.5250 A0.01300 + 100< 0.5500 A0.01300 + 100< 0.51000 A0.01300 + 100< 0.52000 A0.01300 + 100< 0.5Note[2]: RD=Reading,RG=Range, unless otherwise noted; Output range: 10 mA ~ 1050 A\2100 AManual or automatic range switch.Adjustment fineness: 0.002%*RG6 digits decimal displayProtections: open-circuit protection, overload protection, over-heat protection6.2 AC CurrentCopper RingRangeResolutionOutput RangeFrequencyMax Compliance Voltage(rms)Ring 1100 mA1 μA10.000 mA ~ 110.000 mA40 Hz ~ 400 Hz6 V300 mA1 μA30.000 mA ~ 330.000 mA40 Hz ~ 400 Hz6 V1 A10 μA0.10000 A ~ 1.10000 A40 Hz ~ 400 Hz6 V3 A10 μA0.30000 A ~ 3.30000 A40 Hz ~ 400 Hz6 V10 A100 μA1.0000 A ~ 11.0000 A40 Hz ~ 400 Hz6 V30 A100 μA3.0000 A ~ 33.0000 A40 Hz ~ 400 Hz6 V100 A1 mA10.000 A ~ 110.000 A40 Hz ~ 400 Hz6 VRing 2250 A1 mA20.000 A ~ 275.000 A40 Hz ~ 400 Hz6 V500 A1 mA50.000 A ~ 550.000 A40 Hz ~ 400 Hz6 V1000 A10 mA100.00 A ~ 1020.00 A40 Hz ~ 400 Hz6 V2000 A [3]10 mA200.00 A ~ 2050.00 A40 Hz ~ 400 Hz6 V RangeStability (±%/min)Accuracy ±(ppm*RD+ppm*RG)Distortion (%)100 mA0.01300 + 100<0.5300 mA0.01300 + 100<0.51 A0.01300 + 100<0.53 A0.01300 + 100<0.510 A0.01300 + 100<0.530 A0.01300 + 100<0.5100 A0.01300 + 100<0.5250 A0.01300 + 100<0.5500 A0.01300 + 100<0.51000 A0.01300 + 100<0.52000 A [1]0.01300 + 100<0.5Note[3]: Range 2000 A is optional.Output range: 10 mA ~ 1020 A (2050 A)Frequency: 40 Hz ~ 400 Hz, adjustment fineness 0.001 Hz,accuracy ±0.01%.Adjustment fineness: 0.002%*RG6 digits displayProtections: open-circuit protection, overload protection, over-heat protection6.3 DC Voltage(optional)RangeResolutionOutput RangeMax Burden200 mV1 μV20.000 mV ~ 220.000 mV100 mA1 V10 μV0.10000 V ~ 1.00000 V100 mA10 V100 μV1.0000 V ~ 11.0000 V100 mA30 V100 μV3.0000 V ~ 33.0000 V600 mA100 V1 mV10.000 V ~ 110.000 V200 mA300 V1 mV30.000 V ~ 330.000 V60 mA600 V1 mV60.000 V ~ 660.000 V25 mA1000 V10 mV100.00 V ~ 1100.00 V20 mA RangeStability (±%/min)Accuracy ±(ppm*RD+ppm*RG)Ripple Factor (%)200 mV0.01300 + 200<0.51 V0.01300 + 200< 0.510 V0.01300 + 200< 0.530 V0.01300 + 200< 0.5100 V0.01300 + 200< 0.5300 V0.01300 + 200< 0.5600 V0.01300 + 200< 0.51000 V0.01300 + 200< 0.5Output range: 20 mV ~ 1100 VManual or automatic range switchAdjustment fineness: 0.002%*RG6 digits displayProtections: short-circuit protection, overload protection, over-heat protection6.4 AC Voltage(optional)RangeResolutionOutput RangeFrequencyMax Burden(rms)10 V100 μV1.0000 V ~ 11.0000 V40 Hz ~ 400 Hz800 mA30 V100 μV3.0000 V ~ 33.0000 V40 Hz ~ 400 Hz700 mA100 V1 mV10.000 V ~ 110.000 V40 Hz ~ 400 Hz200 mA300 V1 mV30.000 V ~ 330.000 V40 Hz ~ 400 Hz70 mA750 V1 mV75.000 V ~ 825.000 V40 Hz ~ 400 Hz30 mA RangeStability(±%/min)Accuracy ±(ppm*RD+ppm*RG)Distortion Factor (%)10 V0.01300 + 200<0.530 V0.01300 + 200<0.5100 V0.01300 + 200<0.5300 V0.01300 + 200<0.5750 V0.01300 + 200<0.5Output range: 1 V ~ 825 VFrequency: 40 Hz ~ 400 Hz, adjustment fineness 0.001 Hz, accuracy ±0.01%.Manual or automatic range switchAdjustment fineness: 0.002%*RG6 digits displayProtections: short-circuit protection, overload protection, over-heat protection6.5 DC Resistance(optional)RangeResolutionOutput RangeAccuracy ±(ppm*RD+ppm*RG)Allowable Current100 Ω1 mΩ10.000 Ω ~ 110.000 Ω300 + 2001 mA ~ 50 mA1 kΩ10 mΩ0.10000 kΩ ~ 1.10000 kΩ300 + 200100 μA ~ 5 mA10 kΩ100 mΩ1.0000 kΩ ~ 11.0000 kΩ300 + 20010 μA ~ 500 μA100 kΩ1 Ω10.000 kΩ ~ 110.000 kΩ300 + 20010 μA ~ 50 μA1 MΩ10 Ω0.10000 MΩ ~ 1.10000 MΩ300 + 2001 μA ~ 5 μA10 MΩ100 Ω1.0000 MΩ ~ 11.0000 MΩ600 + 400100 nA ~ 500 nAOutput range: 10 Ω ~ 11 MΩManual or automatic range switchAdjustment fineness: 0.002%*RG6 digits display6.6 AC\DC Power(optional)TypeCurrent RangeCombination of Voltage and CurrentAccuracy ±(%*Power Output)[1] [2]DC1000 A(20 mV~1100 V) ×(10 mA~1050 A)0.07~0.292000 A [3](20 mV~1100 V) ×(10 mA~2100 A)0.07~0.29AC1000 A(1 V~825 V) ×(10 mA~1020 A)0.07~0.422000 A[3](1 V~825 V) ×(10 mA~2050 A)0.07~0.42 6.7 Phase and Power Factor(45 Hz~65 Hz)(optional)TypeRangeAdjustment finenessAccuracy[1]φ0.000°~359.999°0.005°0.1°λ-1 … 0 … +10.00010.30% @ (λ=0.5)Note[1]: The accuracy formula of Power Factor: 7. General SpecificationsPower supplyAC (380±38)V,( 50 ± 2 ) HzMax Power Consumption16 kVA @ 1000 A Model,32 kVA @ 2000 A ModelOperating Condition0°C~40°C,(20%~85%) R·H,non-condensingStorage Condition-20°C~70°C,(10%~95%) R·H,non-condensingStandard InterfacesRS232×1DimensionsRangeWidth(W)Depth(D)Height(H)Diameter of the copper ringRing 1(?1)Ring 2(?2)1000 A740 mm1723 mm1467 mm10 mm19 mm2000 A1480 mm1723 mm1467 mm10 mm27 mm8. Ordering informationFunctionAC/DC Current Output( ACI & DCI )AC/DC Voltage Output ( ACV & DCV )Resistance Output(Res )Power Output(Power)TD1050-X★---TD1050-X-M★★★★ Company Profile
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...