IPDB › China Industry › Industrial Equipment & Components
China, Chinese Wholesale Price Original Madewelle Gas Solenoid Valves Devg 40 for Industrial Combustion1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Boiler FurnaceBoiler PartsGas ValveGas Solenoid Valve
Shenzhen YHG Heating Science & Technology Co., ltd
Preview:
Product Description Wholesale Price Original Madewelle Gas Solenoid Valves DEVG 40 For Industrial Combustion OVERVIEW This gas solenoid valve can be widely used in the field of gas safety transmission control, to provide the opening and closing or emergency cut off gas supply.Can be used in gas medium, such as natural gas, methane, liquefied petroleum gas, etc.PRODUCT PARAMETERSNameSolenoid ValveBrandMadewelleModelDEVG 40OriginCanadaDeliver Time3~15 daysUsagegas burner accessories Technical parameters:Open time: < 1 secondClosing time: < 1 secondMaximum working frequency: 20 times per minuteMaximum working pressure: DN10-25 360 mbar;200 mbar dn32 - 100Equipped with G1/4 size bypass holeThe built-in filterProtection grade: IP54Rubber sealing material: work mealWith the valve body material: aluminum alloyAISI 302 steel springAmbient temperature: 15 oC to 60 oCThe coil temperature: 65 oC Gas solenoid valve installation using precautions:1, when installation should choose smaller horizontal vibration period of advisable, (the following installation allows 90 degrees, more than DN65 allows only horizontal installation.2, the parameters of the electromagnetic valve nameplate shall be consistent with the actual use requirement.3, the electromagnetic with the arrow on the valve body shall be consistent with the medium flow direction.4, in order to guarantee the normal use of electromagnetic valve, please add special gas filter in front of the valve.5, this valve itself has no explosion proof performance.6, before installation, please thoroughly purge piping, in order to avoid foreign object damage cause electromagnetic valve diaphragm failure.7, such as installing the outdoor and harsh environments should be tested for the corresponding effective protection.8, when the electromagnetic valve failure, in order to timely isolation and convenience of maintenance, installation of a bypass (bypass) device is recommended.9, if the valve opening and closing failure in use, can check whether the coil is power; The use of power supply and medium pressure is normal.10, the electromagnetic valve not installed, can be stored in 0 ~ 40 oC, environment temperature of indoor relative humidity of 80% or less non-corrosive gases, are not allowed in open air.RECOMMEND PRODUCTS ABOUT UShttps://yhg688.en.made-in-china.com/company-Shenzhen-YHG-Heating-Science-Technology-Co-ltd.html
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...