IPDB › China Industry › Tools & Hardware › Cable Tools
China, Chinese Portable Fiber Optic/Optical Test Equipment/Tool Power Meter1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Cable ToolsOptical Power MeterOptic Power Meter
FIBERLINK COMMUNICATION LIMITED
Preview:
Product Description Portable Fiber optic/optical test equipment/tool power meterOverviewFLK-PM630 Portable optical power meter is an accurate and durable handheld meter designed for the installation, operation and maintenance of optical fiber network. It is a compact device with backlight switch and auto power on-off ability. Besides, it provides ultra-wide measurement range, high accuracy, user self-calibration function and universal port. In addition, it displays linear indicators (mW) and non-linear indicators (dBm) in one screen at the same time.FeaturesSelf calibration by user himselfRechargeable lithium battery supports continuous work for up to 48 hours.Linear indicators (mW) and non-linear indicators (dBm) display in one screenUnique FC/SC/ST universal port (see Figures 1, 2), no complex conversionOptional auto power-off abilityBacklight ON/OFFSpecificationsModelABMeasurement range-70~+10-50~+26Type of probeInGaAsRange of wave length800~1700Uncertainty±5%Standard wave length (nm)850,980,1300,1310,1490,1550ResolutionLinear indication: 0.1% Logarithmic indication: 0.01dBmWorking temperature (oC)-10~+60Storage temperature (oC)-25~+70Auto power-off time (min)10Continuous working hoursAt least 48 hoursDimensions (mm)190×100×48Power supplyRechargeable lithium batteryWeight(g)400Notice:Range of wave length: a standard working wave length that we specified: λmin - λmax, the optical power meter within this range can work well with all indicators meeting requirements.Measurement range: the maximum power that the meter can measure as per required indicators.Uncertainty: the error between the test results and standard test results over a popular optical power. Function descriptionsLCDIt displays the optical power measurement results in forms of dB, dBm, mW, uW, nW; the set wave length is 850nm , 980 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, etc.ON/OFFTo power on the meter, press and hold ON/OFF till information appears in LCD; while in power-on state, press the key to power off the meter.dBMeasure relative optical power under preset wave lengthZEROPress this key to zero the optical power meter.λPress λ key to select wave length, there are six wave length, i.e.: 850nm , 980 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm for your choice, their values will appear in LCD respectively.LIGHTPress this key to turn on/off the back light of LCD.7,AUTOOFFPress this key to enable or disable AUTOOFF function of the meter.Operating InstructionsPower ON/OFFPress and hold ON/OFF on the panel till information appears in LCD.Press ON/OFF on the panel, information disappears from LCD, the meter is powered off.Measure absolute optical powerPower on the optical power meter. Set wavelength to be measured, press λ key to select wave length, the default wavelength will be 1310nm. Connect in the light to be measured, the values that screen shows are current measurement results, including linear and non-linear power valueMeasure relative optical powerSet wavelength to be measured.Connect in the light to be measured while in absolute measurement mode, get current power value. Press db key, current optical power value will become current reference value (in unit of dBm).Connect in another light to be measured, the absolute optical power value and relative optical power value of current light will appear in the screen.Special functionsThe product provides three modes, i.e.: factory mode, user mode and working mode, it usually enters working mode.Factory modeThe measurement and calibration are made by the factory.User modePress λ+Light together, the system will enter user mode, and the "nm" at the end of the first line will be absent. Press λ+Light together again, the system will exit user mode and enter working mode, the "nm" at the end of the first line will appear again.Functions of keysFunctionsKeysIncrease by 0.05LightDecrease by 0.05dBSaveZeroChange wave lengthΛReset default settingsλ+ ZeroRemarks: in the event error occurs when user calibrates or operates the meter himself, he can press λ+ Zero together while in User Mode to reset default settings.10 minutes' auto offPress AUTOOFF to enable AUTO OFF function, the icon "OFF" will appear on the left top of the screen, then the meter will automatically turn off if there are no operations within 10 minutes.LED backlight ON/OFFWhile in working mode, press LIGHT to turn on backlight, the symbol "a little sun" will appear on the left top of the screen indicating backlight is on.Serial port commissioningConnect serial port plug to PC's serial port, you can access data and calibrate the meter (see the Figure on the right) via PC.ChargingWhile in normal working, the power volume indicator will not appear in the screen; however, when the battery is going to run out, the power volume indicator will blink once a second, the meter will automatically power off after the indicator blinks for ten times; if so, you can insert the meter into supplied charger for charging (see the Figure on the right), this way saves a lot of trouble and cost in replacing battery.Standard configurationsNameHostRechargeable lithium batteryWarranty cardOxford soft bagChargerData cable (optional)Pass CertificateMaintenance1. Regularly clean the end of sensor, keep it free of grease, dirt. Don't use dirty, non-standard connector, don't insert in the end in poor polishing conditions, otherwise the sensor's end may be damaged, otherwise the performance of entire system may degrade.2. Use only one adapter if possible.3. If you are not going to use the tester for the time, cover the dust-proof cap immediately to keep the end clean. Long-time exposure in air may gather dust therefore influencing measurement accuracy.4. Plug and unplug the adapter with care, don't leave any scratches on the ports.5. Regularly clean the surface of sensor, when cleaning the sensor, please gently wipe the surface using cotton swab by circling the perimeter.TroubleshootingFault descriptionDiagnosisSolutionLCD image is weakPower is insufficientCharge the meterNo display after power-onPower is insufficient / other reasonRestart / charge the meterNo charge or a little charge in LCD readingsOptical adapter's connector is faulty or contaminated/ display is lockedCheck whether the optical adapter's connector is properly connected, clean the terminal of sensor.WarrantyNo parts of the product can be repaired by user himself. Warranty period: 18 months since the date of shipment. If any product defects within the above said period, we will repair or replace the defective product; however, in no events we will bear responsibilities in excess of the product's sales price.If any fault occurs during usage, user can first solve them according to above trouble-shooting instructions, however, if such efforts fail, the user shall not open the cabinet of the product, he should contact our market department or local dealers.For any quality problem arising of production defect, the manufacturer will repair or replace the defective product free of charge, however, any damage caused by improper-operation or good product will not be covered by the above warranty.Notwithstanding the foregoing terms, any problem/fault caused for the following reasons are not included warranty. The product has been repaired or modified without the authorization of the manufacturerThe problem or fault arising of improper use, negligence or incidence.The product is accompanied by a Warranty Registration Card, please complete it and send it back to us together with a photocopy of the invoice, they will be used as the voucher for any maintenance, technical update or calibration that we may make in the future.Appendix: measurement of optical fiber lossStep 1 Set reference valuePower on optical power meter, press λ key to select a proper working wave lengthTurn on light source (emitter), select a proper wave length and keep it steady (it may take 1-2 minutes).Select a optical fiber jumper to connect light source, we call it emitter jumper, clean the connector of emitter jumper. Note the optical fiber that the emitter jumper uses must be identical the optical fiber that the optical link to be tested uses.Connect light source (emitter) with the optical power meter using emitter jumper.Current optical power value is measured.Notice: the power value that we get now should be approximate to the preset value of the light source (emitter), if the bias is too great, please carefully clean all connection terminals or replace the emitter jumper.Press dB key, the moment dB reading is 0.00, and set the power measurement result as reference value.Notice: after you zero the meter, the number of digits after the decimal point may change a little; this is not an indicator of fault.Step 2 Measure loss of optical fiber linkMake the emitter jumper and light source (emitter) continuously connected.Connect the light source (emitter) with the optical fiber link to be measured.Notice: clean all connection terminals including necessary optical fiber adapter.The reading appearing in the screen now is the loss of the measured optical fiber link; its unit is dB (current absolute power value is displayed in dBm form at the same time).Related productsOur fiber patch cord production line:CertificationsShipping:Service:1.Professional manufacturer, 100% tested.2.Customers solutions in days, not weeks.3.Warmly services with careful attentions.4.Can provide your specific inquiry within 24 hours.5.Save much costs, bring more benefit for customer to expand business. 6.We have been 9 years experience in this field. We are the prefessional supplier that you can trust.FAQQ1:How can you guarantee the delivery time? A:1. To avoid the delay, we have built a complete and professional procedure system from production to the deliver and have rich experience.2. We can regulate the penalty clause in the contract for the late delay. Q2:What's your best price?A:Based on the quality of our products and the quantity of your estimated. We would quote the great best matching price all the time. Q3:What's your MOQ? A:Low MOQ, 1pc for sample checking is available Q4:Can I print our own logo on the product?A:Yes, Please send your logo to us. Q5:Can you provide OEM/ODM service?A:Yes, we can. Please tell us the details of your requirementsQ6: How to deal with the faulty?A: Firstly, Our products are produced in strict quality control system and the defective rate will be less than 0.2%.Secondly, during the guarantee period, we will send new with new order for small quantity. For defective batch products, we will repair them and resend them to you or we can discuss the solution including re-call according to real situation.Q7:Why choose us to cooperate?1. We have first-class production line and strict quality management system.2. We have professional procedure system and big production capacity to guarantee fast deliver and on time shipment.3. We can provide the most competitive price to meet your budget.4. We also design and innovate the new products based on our rich experience .5. We have professional team to provide comprehensive one-stop service for you.Hope this would be a good start for our cooperation!
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...