Send

Food Packaging Bag

Gift Box & Bag

Industrial Packaging Bag

Logistics Packaging

Machinery for Packaging Supplies

Non Woven Bag

Other Bags & Cases

Package & Conveyance

Package & Printing Service

Packaging Bags

Packaging Materials

Packing Bottle

Packing Machinery

Post-Press Equipment

Pre-Press Equipment

Printing Machinery

Printing Materials

Shopping Bags

Specialized Case & Box

Stencil

Tag & Sign

Tag Gun

Tool Packaging

Watch Box

IPDBChina IndustryInstruments & Meters



China, Chinese TA4600 Premium Power Quality Calibration Source for Electrical Testing1 Industrial Products Supplier Manufacturer Details, price list catalog:

China Industrial Products Supplier Manufacturer List Catalog
« Previous Next »

Electronic InstrumentCalibratorAdvanced Power Quality SourceElectrical Calibration Source

Tunkia Co., Ltd.

Preview:

Product Description TA4600 Electrical Power Quality Standard Power Source 1.FeaturesDC / Single-phase / Three-phase Voltage Output: 1 V ~ 1008 V;DC / Single-phase / Three-phase Current Output: 10 mA ~ 21 A;Fundamental Frequency Range: 16 Hz ~ 850 Hz;Voltage Accuracy: 0.005% @45 Hz~65 Hz;Current Accuracy: 0.005%*RD+2.5μA @45 Hz~65 Hz;Power Energy Accuracy: 0.01%@ (PF: 0.5 ~ 1);Optimal Accuracy of U-I Phase: 0.003°@ 45 Hz~65 Hz;Voltage and Current Harmonics: 2nd~99th @50Hz / 60HzInterharmonic Frequency Range: 16 Hz ~ 6 kHz2. Function Three-phase Virtual Power Standard Source: Each phase voltage, current, and U-I phase can be controlled independently, supporting three-phase unified adjustment.Power / Energy Signal Output: Can provide standard power and energy signals for traceability calibration.Harmonic Output Function: Both voltage and current can be superimposed on the fundamental wave with the 2nd to 99th harmonics @50Hz / 60Hz. The amplitude and phase (relative to the fundamental wave) of each harmonic can be set independently.Energy Testing: It has pulse input/output function and built-in energy error comparator, which can be used for error detection of electric energy meters.Communication Interfaces: It has various communication interfaces such as RS232, USB, LAN, etc., which facilitates the establishment of a fully automatic test system.Reference Clock Output (CLK): Built-in 10 MHz high-precision reference clock output.Safety Protection Functions: The instrument includes voltage short circuit protection, current open circuit protection, overload protection, etc. The specially designed overcurrent fuse can also be easily replaced. It has the output limit setting function to prevent the output of large voltage or current from damaging the meter under test. The safety protection function can minimize accidental damage to the instrument due to mis-operation and greatly reduce user losses.Current Range Expansion: Programmable feedback control of the transconductance amplifier TA1000 can be achieved to achieve current range expansion. 3. Specifications3.1 Voltage Output3.1.1 DC Voltage OutputOutput Range0~50%*range value (0 V~504 V)Display Digit7-digit display Short Term Stability0.003%/minAnnual Accuracy (tcal±5oC)± (0.009%*reading value+0.01%*range)Maximum Load Current (Peak)1 A (U ≤ 600V range); 71 mA (1000V range) 3.1.2 AC Voltage Output (Sinusoidal)Output Range1 V~1008 VOutput Frequency Range16 Hz~850 HzDisplay Digits7-digit displayShort Term Stability0.0015%/minAnnual Accuracy (tcal±5oC)16 Hz≤F<45 Hz: ± (0.006%* reading value +0.001%* range)45 Hz≤F≤65 Hz: ± (0.004%* reading value +0.001%* range) 65 Hz<F≤850 Hz: ± (0.006%* reading value +0.001%* range)Maximum Load Current (Peak)1 A (U ≤ 600V range); 71 mA (1000V range)Maximum Harmonic Distortion0.016%* set value or 0.003%* range value, use the larger value of the two 3.1.3 AC Voltage Output (Non-sinusoidal)Output Range0~30%* range valueHarmonic Order2nd~99th @50Hz / 60HzShort Term Stability0.002%/minAnnual Accuracy (tcal±5oC)16 Hz≤F≤850 Hz:±(0.006%* reading value +0.002%* range)850 Hz<F≤6 kHz:±(0.045%* reading value +0.0024%* range)Maximum Load Current (Peak)1 A(U ≤ 600V range); 71 mA(1000V range)Maximum Harmonic Distortion16 Hz≤F≤850 Hz: 0.016%* set value or 0.003%* range value, use the larger value of the two 850 Hz<F≤6 kHz: 0.25%* set value or 0.015%* range value, use the larger value of the two3.2 Current Output3.2.1 DC Current OutputOutput Range0 A~24 ADisplay Digits7-digit displayShort Term Stability0.003%/minAnnual Accuracy (tcal±5oC)± (0.009%*reading value +0.01%*range)Maximum Compliance Voltage (Peak)14 Vpk@ (0.25A~10A range) 3.2.2 AC Current Output (Sinusoidal)Output Range0.1 A~80 AOutput Frequency Range16 Hz~850 HzDisplay Digits7-digit displayShort Term Stability0.002%/minAnnual Accuracy16 Hz≤F<45 Hz: ± (0.006%* reading value+0.002%* range)45 Hz≤F≤65 Hz: ± (0.005%* reading value+0.001%* range)65 Hz<F≤850 Hz: ± (0.006%* reading value+0.002%* range)Maximum Compliance Voltage (Peak)14 Vpk@(0.25A~10A range)Maximum Harmonic Distortion0.01%* set value or 0.003%* range value, use the larger value of the two 3.2.3 AC Current Output (Non-sinusoidal)Output Range0.1 A~24 AHarmonic Order2nd~99th @50Hz / 60HzShort Term Stability0.002%/minAnnual Accuracy (tcal±5oC)16 Hz≤F≤850 Hz: ± (0.006%* reading value +0.002%* range)850 Hz<F≤6 kHz: ± (0.04%* reading value +0.002%* range)Maximum Compliance Voltage (Peak)14 Vpk@(0.25A~10A range)Maximum Harmonic Distortion16 Hz≤F≤850 Hz: 0.016%* set value or 0.003% range value, use the larger value of the two850 Hz<F≤6 kHz: 0.25%* set value or 0.015% range value, use the larger value of the two3.3 AUX (Voltage on Current Terminals)3.3.1 DC Voltage OutputOutput Range0~50%* range value (0 V~5 V)Display Digits7-digit displayShort Term Stability0.003%/minAnnual Accuracy (tcal±5oC)±(0.009%* reading value +0.014%* range) 3.3.2 AC Voltage Output (Sinusoidal)Output Range0.05 V~10 VOutput Frequency Range16 Hz~850 HzDisplay Digits7-digit displayShort Term Stability0.002%/minAnnual Accuracy (tcal±5oC)45 Hz≤F≤65 Hz: ± (0.005%* reading value +0.002%* range)16 Hz<F≤850 Hz: ± (0.006%* reading value +0.002%* range)Maximum Harmonic Distortion0.010%* set value or 0.001%* range value, use the larger value of the two 3.3.3 AC Voltage Output (Non-sinusoidal)Output Range0~3VHarmonic Order2nd~99th @50Hz / 60HzShort Term Stability0.002%/minAnnual Accuracy (tcal±5oC)16 Hz≤F≤850 Hz: ± (0.0065%* reading value +0.0020% range)850 Hz<F≤6 kHz: ± (0.04%* reading value +0.0030%* range)Maximum Harmonic Distortion16 Hz≤F≤850 Hz: 0.010%* set value or 0.001%* range value, use the larger value of the two850 Hz<F≤6 kHz: 0.100%* set value or 0.01%* range value, use the larger value of the two3.4 PhaseFrequencyAnnual Accuracy (tcal ±5oC)>40% Range Voltage and Current Components0.5%~40% Voltage or Current ComponentU-IU-U(Polyphase Operation)U-IU-U(Polyphase Operation)16Hz ~ 69Hz 0.003°0.005°0.010°0.010°69Hz ~ 180Hz0.007°0.007°0.017°0.017°180Hz ~ 450Hz0.018°0.025°0.050°0.050°450Hz ~ 850Hz0.033°0.043°0.070°0.070°850Hz ~ 3kHz0.115°0.150°0.200°0.200°3kHz ~ 6kHz0.230°0.300°0.450°0.450°3.5 Power3.5.1 Sinusoidal Power Accuracy (Power Factor 1.0)Current RangePower accuracy when current is 90% of the range (ppm)Power accuracy when current is 50% of the range (ppm)When voltage is 62% ~ 70% of the range650V & 1008V Range: 70%~75%When voltage is 7% ~ 100% of the range650V&1008V Range: 70%~75%23 V~ 90 V Range180 V &360 V Range23 V~ 90 V Range180 V & 360 V Range0 ~ 2A 6264647274745 A~ 20A 656666747575 3.5.2 Sinusoidal Power Accuracy (Power Factor 0.5)Current RangePower accuracy when current is 90% of the range (ppm)Power accuracy when current is 50% of the range (ppm)When voltage is 62% ~ 70% of the range650V &1008V Range: 70%~75%When voltage is 7% ~ 100% of the range650V&1008V Range: 70%~75%23 V~ 90 V Range180 V& 360 V Range23 V~ 90 V Range180 V & 360 V Range0 ~ 5A 93949410010110110 A~ 20A 959696102102102 3.5.3 Non-sinusoidal Power Accuracy (Power Factor 1.0, 20%THD)Current RangePower accuracy when current is 90% of the range (ppm)Power accuracy when current is 50% of the range (ppm)When voltage is 62% ~ 70% of the range650V & 1008V Range: 70%~75%When voltage is 7% ~ 100% of the range650V& 1008V Range: 70%~75%23 V~ 90 V Range180 V& 360 V Range23 V~ 90 V Range180 V & 360 V Range0 ~ 5A 97989810310510510 A~ 20A 989999105105105Note: For electric energy technical indicators, add 1ppm to the power indicator.3.6 Energy3.6.1 Pulse InputMaximum Frequency5MHzMaximum Frequency100 nsMaximum Count Per Channel232-1 3.6.2 Pulse and Gate-control InputInput Low Level Max Value1VInput High Level Max Value3VInternal Pull-Up Value135Ω and 940Ω to 4.5V nominalApproximately equivalent to 150Ω/1kΩ to 5V nominalMax Input Voltage28VMin Input Voltage0V 3.6.3 Pulse OutputDriveOpen-collector, optional internal 470Ω pull-upFrequency Range1mHz to 5MHzFrequency Accuracy±(10ppm+100nHz)External Pull-Up Voltage30V maxSink CurrentMax 150mA 3.6.4 Gate-control OutputDriveOpen-drainInternal Pull-UpThe value same as gate inputExternal Pull-Up Voltage30V maxSink CurrentMax 1A 3.6.5 AccuracyTiming Accuracy± (10ppm+100ns)Gate-control Mode Accuracy± (10ppm+100ns) Packet Mode Accuracy (Ppm)± (Output power (ppm)+10ppm+110 000/test period)3.7 FlickerSet Range± 30% of setting valueFlicker Modulation Depth Accuracy0.025%Setting Accuracy of Modulation Depth0.001%Modulation Envelope ShapeSquare or sine waveDuty Factor (Square Wave)0.01% ~ 99.99%; accuracy = ±31 μsModulation Unit0.5Hz ~ 40HzModulation Frequency Accuracy<0.13%3.8 Modulation HarmonicsNumber of Modulating Harmonics0 to all set harmonicsModulation Depth Setting Range0% ~ 100% of nominal harmonic voltageModulation Accuracy (0% ~ ±30%)± 0.025%Setting Accuracy of Modulation Depth0.001%WaveformSquare wave or sine waveDuty Factor (Square Wave)0.01% ~ 99.99%Modulation Frequency Range0.008Hz~30HzSine Wave Modulation Frequency Accuracy± (50ppm+10μHz)Square Wave Modulation Frequency Accuracy<1300ppmModulation Frequency Setting Resolution0.001Hz3.9 InterharmonicsFrequency Accuracy± 500ppmAmplitude Accuracy When 16Hz≤F<6kHz± 1%Amplitude Accuracy At >6kHz4%Max Value of Single InterharmonicThe maximum value of interharmonic below 2850Hz is 30% of the rangeInterharmonic Frequency Range16Hz ~ 9khz3.10 Voltage Swell and SagMin Duration1msMax Duration1minMin Amplitude of Sag0% of nominal outputMax Rapid SwellFull scale value or 140% of nominal output, whichever is smallerRise/Fall Time100 μs ~ 30s configurableOptional Repeat with Delay0~ (60s ±31 μs)Triggering Level Amplitude Accuracy±0.025%*level valueSwell And Sag Level Amplitude Accuracy±0.25%*level valueTriggerThe falling edge of TTL is consistent with the trigger delay end time and remains low level of 10μs ~ 31μs Company Profile  

Link supplier or manufacturer »

Instruments & Meters: TA4600 Premium Power Quality Calibration Source for Electrical Testing
Inscinstech Protein Purification System (Unique AutoPure300) Protein Purification Techniques1603byte
ID200*650 Preparative Purify HPLC System1844byte
Fps-100c Single Channel Automatic Peptide Synthesizer1323byte
Inscinstech Lab Instrument Automatic Large Scale Oligonucleotide Synthesizer (Unique AutoOligo25) for The Rapid Synthesis of 10~100μ Mol Nucleic Acid Samples648byte
ID1400*500mm Auto Acrylic Column Column, Bed Lenght 500mm1439byte

ID600mm Purify HPLC System for Natural Plant1537byte
Inscinstech Automatic Large Scale Oligonucleotide Synthesizer (Unique AutoOligo100) for The Rapid Synthesis of 50 μ Mol-9 Mmol Nucleic Acid Samples640byte
Factory Price HPLC High Performance Liquid Chromatography with Isocratic And Gradient System2545byte
Chromatographic Columns USP L1 L8 L11 L10 L Ods Cn C18 C8 Normal Phase / Reverse Phase HPLC Column4416byte
Inscinstech Lab Instrument Protein Purification System (Unique AutoPure150-L1) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP822byte

50dac Preparative Purify HPLC System2241byte
High Efficiency One Stop Solution Chromatograph Machine HPLC Systems High Performance Liquid HPLC Chromatography2545byte
Laboratory High Performance Liquid Chromatography Machine HPLC Chromatography LC-W100A2771byte
LC Laboratory High Performance Liquid Chromatography HPLC with UV Detector for Food Analysis7365byte
100ml Fplc Chromatography for Cetuximab1701byte

Inscinstech Ion Chromatography Protein Purification System (Unique AutoPure25-L1) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP811byte
Biobase HPLC High Performance Liquid Chromatography System Gas Chromatograph5402byte
Biobase Eclassical 3100 Laboratory High Performance Liquid Chromatography System for Laboratory HPLC1278byte
Mass Spectrometer Gas Chromatograph with Fid Detector4942byte
Dw-Gc1120 Economic Gc System Gas Chromatography Fid Tcd Ecd Npd Lab Gas Chromatograph Machine3011byte

High Accuracy Transformer Oil Gas Analyzers Price Dissolved Gas Analysis Equipment GC MS Insulating Oil Gas Chromatograph3258byte
SCITEK Gas Chromatograph Self-Diagnostic System Chromatograph With Seamless PC Control3341byte
Explosion Proof Real-Time Industrial Online Process Analyzer Industrial Online Gas Chromatograph4030byte
Double Beam UV-Vis Spectrophotometer / Spectroscopy Instrument1546byte
2025 RoHS Directive Detection Edxrf Energy Dispersive X-ray Fluorescence Spectrometer2432byte

Gas Chromatograph Mass Spectrometer Gc-Ms4084byte
Laboratory High Performance Liquid Chromatography HPLC with UV Detector for Food Analysis952byte
Inscinstech Protein Purification System Lab Instrument (Unique AutoPure100-L2) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP1569byte
1000ml Ss Pump for Ion Chromatography Pump1448byte
Gc112A Lab Gas Chromatograph Analysis Instrument2874byte

Alva SPD620 Laboratory Sample Pretreatment Digestion Instrument with Metal Heating Module, Chemistry Lab Instrument7790byte
China Factory High Efficiency Kjeldahl Digestion Furnace for Lab Use2011byte
High Precision High Frequency Infrared Carbon Sulfur Analyzer for Alloy Plant5415byte
Carbon Silicon Tester for Foundries Is Used for Pre-Furnace Scarbon Silicondetection of Gray Cast Iron Ductile Cast Iron Foundry Molten Iron Testing Equipment3289byte
Unparalleled Accuracy in Carbon Sulfur Testing with Our Superior Technology Xrf ACP Aas Manufacture6697byte

Aurispec P3 Xrf, Portable Analyzer, Gold Tester, Spectrometer1348byte
Automatic Fat Analyzer SD-P6s for Measuring Fats and Other Compounds Using The Soxhlet Extraction Principle8780byte
Sequential Inductively Coupled Plasma Emission Spectrometer-Icp-Oes/Icp-AES 5% off1756byte
Automatic Kjeldahl Nitrogen Analyzer for Food Crops and Feeds2445byte
High Precision Portable Chlorophyll Meter3412byte

High Precision and Speed with Mining Steel Carbon Sulfur Analyzer6697byte
Digital Oxygen Nitrogen Hydrogen Analyzer for The Determination of Steel1896byte
Aurispec B6t, Benchtop Xrf, Coating Thickness Analyzer, Element Analyzer, Soil, Spectrometer2421byte
Casting Furnace Front Carbon and Silicon Analyzer Automatic Analysis and Automatic Printing5945byte
Fd6800 Fiber Analyzer: Fully Automated Chemistry Elemental Analyzer for Sensitive Detection of CF, Adf, Ndf, Cellulose, and Lignin8082byte

Nanbei Crude Protein Analysis Automatic Kjeldahl Nitrogen Analyzer5041byte
Drawell Portable Xrf Gold Tester Handheld Xrf Mineral Analyzer X-ray Fluorescence Spectrometer2331byte
CS995 High-Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral Coal3201byte
Handheld Smart Mini Poct Automated Blood Gas and Electrolyte Analyzer Electrode Method Blood Analyzer for Hospital Use (SG1)1327byte
Hand-Held Pesticide Residue Meter for Food Safety Meter4150byte

Xrf Sulfur Analyzer X-ray Sulfur Analzyer 5% off1089byte
Desktop Liquid Security Detector Liquid Trace Detector695byte
High Quality Single Flame Atomic Absorption Spectrometer for Lab4823byte
Innovate High-Frequency Infrared Carbon & Sulphur Analyzer5536byte
Carbon Silicon Analyzer for Molten Iron Fast Foundry Thermal Analysis System Cup Sampling Furnace QC Testing Carbon Equivalent Measurement on-Site Liquid Metal5549byte

Full Automatic High Frequency Laboratory Equipment Analysis Instrument Testing Machine Metal Detector Chemistry Analyzer Metal Infrared Carbon Sulfur Analyzer6669byte
Semi-Auto Kjeldahl Protein Analyzer From Factory2538byte
High-Precision Kjeldahl Nitrogen Protein Measurement Equipment for Labs3768byte
Aurispec H3 Xrf, Portable Analyzer, Gold Tester, Spectrometer2229byte
ED6 Plus Liquid-Liquid Extractor: Fully Automated Chemistry Lab Instrument for Multi-Sample Extraction with Advanced Control8202byte

Portable Gas Detector The Gas Leak Detector Is Suitable for The Detection of C2h4 H2 CH3oh C4h10 C2h6o and Other Gases4250byte
Ethylene Oxide Alarm, Industrial Explosion-Proof Gas Leak Detector, Concentration Detector C2h4o Gas Detector3367byte
Quick Fuel Cell Tester LCD Screen Rapid Alcohol Breathalyzer945byte
O2 Auto Detector System 8 Channel Fixed Gas Leak Analyzer Controller2700byte
Exhaust Gas Analyzer Automotive Exhaust Gas Analyzer2840byte

Y09-310 (AC-DC) 28.3 L/Min Battery Operated Laser Particle Counter for Clean Rooms3401byte
Factory Price Shc-300 Alkaline Water Electrolysis Hydrogen Generator for Fid1955byte
Drop Wire FTTH Optical Fiber Cable 1000m/Wood1730byte
Cost-Effective Portable Oil Particle Counter Lubricant Oil Water Content Tester Online Particle Meter8434byte
High Quality Jy-Ecpt3000 Electrophoresis Power Supply with Constant-Voltage for Lab1983byte

Laboratory Acidity Alkalinity Redox Titration Benchtop Digital Automatic Potential Potentiometric Titrator2848byte
Iot Sensor3333byte
Automatic Fluoride Monitoring System for Sewage Treatment Equipment Spectrophotometry1948byte
as-300A Automatic Hall Flowmeter for Metals2041byte
Dlab Brand Laboratory Equipment Mx-T6-S Blood Roller Mixer1411byte

Metallographic Inlay Manual Model Xq-1 Metallurgical Sample Mounting Press3325byte
Alpha-610 Advanced Lab-Grade Automatic Metallographic Grinding and Polishing Machine2947byte
Quick Temperature Measurement Thermocouple for Fast Temperature Readings4468byte
Cheap Price Paper Tube Sampler Immersion Fast Response Sampler for Molten Metal5087byte
Precise Rated Type K 602 604 Measuring Thermocouple Connector Thermocouple4685byte

Factory Manufacturing Customizable Metal Immersion Disposable Iron Sampler4555byte
High Pressure Laboratory Sample Low Price Flexpress Screen Display Vacuum Automatic Metallographic Specimen Mounting Molds and Clamps Press Machine2483byte
Long - Lasting T-35K Type Armored Rapid Temperature Measurement Thermocouple4685byte
Mt-1h Automatic Hydraulic Specimen Precision Metallographic Mounting Equipment Professional Lab-Grade Sample Preparation Machines for Microscopy Analysis2510byte
High Accuracy Industrial Grade 602 604 Temperature Measuring Thermocouple4685byte






Purchasing Request


Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...

  • Professiona Secured Trading Service
  • Verified Business Licenses to Supplier or Manufacturer
  • Welcome to our Global alliance Member