IPDB › China Industry › Instruments & Meters
China, Chinese Tektronix Keithley 2450 Sourcemeter Smu Instrument1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Meter for ElectricityMultimeterKeithleyVoltmeter
Shenzhen HOBOY Instruments Co., Ltd.
Preview:
Product Description Product Parameters Keithley 2450 Graphical SourceMeter (SMU) Instrument with GPIB, USB, And Ethernet InterfacesChannels: 1Power: 20 WMax Current Source/Measure Range: 1AMax Voltage Source/Measure Range: 200VMeasurement Resolution: 10fA / 10nVCapabilities of analyzers, curve tracers, and I-V systems at a fraction of their costFive-inch, high resolution capacitive touchscreen GUI0.012% basic measure accuracy with 6?-digit resolutionEnhanced sensitivity with new 20mV and 10nA source/measure rangesSource and sink (four-quadrant) operationFour "Quickset" modes for fast setup and measurementsBuilt-in, context-sensitive front panel helpFront panel input banana jacks; rear panel input triaxialDescriptionKeithley 2450 - SourceMeter Instrument (200 V, 1 A, 20 W) Channels: 1Power: 20 WMax Current Source/Measure Range: 1AMax Voltage Source/Measure Range: 200VMeasurement Resolution: 10fA / 10nVThe 2450 is Keithley's next-generation SourceMeter source measure unit (SMU) instrument that truly brings Ohm's law (current, voltage, and resistance) testing right to your fingertips. Its innovative graphical user interface (GUI) and advanced, capacitive touchscreen technology allow intuitive usage and minimize the learning curve to enable engineers and scientists to learn faster, work smarter, and invent easier.The 2450 is the SMU for everyone: a versatile instrument, particularly well-suited for characterizing modern scaled semiconductors, nano-scale devices and materials, organic semiconductors, printed electronics, and other small-geometry and low-power devices. All this combined with Keithley SMU precision and accuracy allows users to Touch, Test, Invent? with the new favorite go-to instrument in the lab for years to come.2450 main home screen.Learn Faster, Work Smarter, and Invent EasierUnlike conventional instruments with dedicated pushbutton technology and small, obscure, limited-character displays, the 2450 features a five-inch, full-color, higher resolution touchscreen that facilitates ease of use, learning, and optimizes overall speed and productivity. A simple icon-based menu structure reduces configuration steps by as much as 50 percent and eliminates the cumbersome multi-layer menu structures typically used on soft-key instruments. Built-in, context-sensitive help enables intuitive operation and minimizes the need to review a separate manual.These capabilities combined with its application versatility make 2450. The SMU instrument inherently easy to use for basic and advanced measurement applications, regardless of your experience level with SMU instruments. Fourth-Generation, All-in-One SMU InstrumentThe 2450 is the fourth-generation member of Keithley's award-winning SourceMeter family of SMU instruments and leverages the proven capabilities of the 2400 SourceMeter SMU Instrument. It offers a highly flexible, four-quadrant voltage and current sourwce/load coupled with precision voltage and current meters. This all-in-one instrument gives you the capabilities of a:2450 power envelopePrecision power supply with V and I readbackTrue current sourceDigital multimeter (DCV, DCI, ohms, and power with 6?-digit resolution)Precision electronic loadTrigger controllerEase of Use Beyond the TouchscreenIn addition to its five-inch, color touchscreen, the 2450 front panel has many features that supplement its speed, user-friendliness, and learnability, including a USB 2.0 memory I/O port, a HELP key, a rotary navigation/control knob, a front/ rear input selector button, and banana jacks for basic bench applications. The USB 2.0 memory port supports easy data storing, saving instrument configurations, loading test scripts, and system upgrades. Plus, all front panel buttons are backlit to enhance visibility in low-light environments.2450 front panel with high-resolution, capacitive touchscreen.Four "Quickset" modes simplify user setup. With one touch, the instrument can be quickly configured for various operating modes without the need to configure the instrument indirectly for this operation.Quickset modes enable fast setup and time to measurements.Comprehensive Built-in ConnectivityRear panel access to rear-input triax connectors, remote control interfaces (GPIB, USB 2.0, and LXI/Ethernet), D-sub 9-pin digital I/O port (for internal/external trigger signals and handler control), instrument interlock control, and TSP-Link? jacks enables easy configuration of multiple instrument test solutions and eliminates the need to invest in additional adapter accessories.Rear panel connections are optimized for signal integrityConvert Raw Data to InformationThe 2450 provides a full plotting and sheet view to display sweeps, measurement data, and charting right on the screen. It also supports exporting to a spreadsheet for further analysis, dramatically improving productivity for research, bench-top testing, device qualification, and debugging. TriggerFlow? Building Blocks for Instrument Control and ExecutionThe 2450 incorporates Keithley's new TriggerFlow triggering system that allows user control of instrument execution. Similar to developing a flow chart, TriggerFlow diagrams are created using four fundamental building blocks:Wait - Waits for an event to occur before the flow continues Branch - Branches when a condition has been satisfied Action - Initiates an action in the instrument, for example, measure, source, delay, set digital I/O, etc. Notify - Notifies other equipment that an event has occurredTriggerFlow building blocks let users create very simple to very complex triggering models.A TriggerFlow model using a combination of these building blocks can be created from the front panel or by sending remote commands. With the TriggerFlow system, users can build triggering models from very simple to complex with up to 63 block levels. The 2450 also includes basic triggering functions, including immediate, timer, and manual triggering.In The Box8608 - High-Performance Test LeadsUSB-B-1 - USB Cable, Type A to Type B, 1 m (3.3 ft)CS-1616-3 - Safety Interlock Mating Connector17469460X - TSP-Link/Ethernet Cable2450 QuickStart GuideTest Script Builder SoftwareKickStart Startup SoftwareLabVIEW and IVI DriversManuals/GuidesBrochuresBrochureManualsKeithley Potentiostats and Galvanostats Users ManualKeithley Source Measurement (SMU) ManualKeithley 2450 SourceMeter Instrument Users ManualPower Supplies Selection GuideSpec SheetsData SheetApplication NotesUsing_Keithleys_All-In-One_Battery_Test_Solution_-_Application_NoteManufacturer SpecsVoltage Specifications 1, 2 SourceMeasure 3RangeResolutionAccuracy (23° ± 5°C) 1 Year ±(% setting + volts)Noise (RMS) (<10 Hz)ResolutionInput ResistanceAccuracy (23° ± 5°C) 1 Year ±(% rdg. + volts)20.00000 mV500 nV0.100% + 200 μV1 μV10 nV>10 GΩ0.100% + 150 μV200.0000 mV5 μV0.015% + 200 μV1 μV100 nV>10 GΩ0.012% + 200 μV2.000000 V50 μV0.020% + 300 μV10 μV1 μV>10 GΩ0.012% + 300 μV20.00000 V500 μV0.015% + 2.4 mV100 μV10 μV>10 GΩ0.015% + 1 mV200.0000 V5 mV0.015% + 24 mV1 mV100 μV>10 GΩ0.015% + 10 mVCurrent Specifications 1, 2 SourceMeasure 3RangeResolutionAccuracy (23° ±5°C)4 1 Year ±(% setting + amps)Noise (RMS) (<10 Hz)ResolutionVoltage BurdenAccuracy (23° ±5°C) 1 Year ±(% rdg. + amps)10.00000 nA5 500 fA0.100% + 100 pA500 fA10 fA<100 μV0.100% + 50 pA100.0000 nA55 pA0.060% + 150 pA500 fA100 fA<100 μV0.060% + 100 pA1.000000 μA50 pA0.025% + 400 pA5 pA1 pA<100 μV0.025% + 300 pA10.00000 μA500 pA0.025% + 1.5 nA40 pA10 pA<100 μV0.025% + 700 pA100.0000 μA5 nA0.020% + 15 nA400 pA100 pA<100 μV 0.020% + 6 nA1.000000 mA50 nA0.020% + 150 nA5 nA1 nA<100 μV0.020% + 60 nA10.00000 mA500 nA0.020% + 1.5 μA40 nA10 nA<100 μV0.020% + 600 nA100.0000 mA5 μA0.025% + 15 μA100 nA100 nA<100 μV0.025% + 6 μA1.000000 A50 μA0.067% + 900 μA3 μA1 μA<100 μV0.030% + 500 μATemperature Coefficient (0°-18°C and 28°-50°C)±(0.15 × accuracy specification)/°C.Notes1. Speed = 1 PLC.2. All specifications are guaranteed with output ON.3. Accuracies apply to 2- and 4-wire mode when properly zeroed.4. For sink mode, 1 μA to 100 mA range accuracy is ±(0.15% + offset × 4). For 1A range, accuracy is ±(1.5% + offset × 8).5. Rear panel triax connections only.Resistance Measurement Accuracy (Local or Remote Sense) 1, 2RangeDefault Resolution 3Default Test CurrentNormal Accuracy (23°C ±5°C) 1 Year, ±(% rdg. + ohms)Enhanced Accuracy 4 (23°C ±5°C) 1 Year, ±(% rdg. + ohms)<2.000000 Ω 51 μΩUser definedSource IACC + Meas. VACCMeas. IACC + Meas. VACC20.00000 Ω10 μΩ100 mA0.098% + 0.003 Ω0.073% + 0.001 Ω 200.0000 Ω100 μΩ10 mA0.077% + 0.03 Ω0.053% + 0.01 Ω2.000000 kΩ1 mΩ1 mA0.066% + 0.3 Ω0.045% + 0.1 Ω20.00000 kΩ10 mΩ100 μA0.063% + 3 Ω0.043% + 1 Ω200.0000 kΩ100 mΩ10 μA0.065% + 30 Ω0.046% + 10 Ω2.000000 MΩ1 Ω1 μA0.110% + 300 Ω0.049% + 100 Ω20.00000 MΩ10 Ω1 μA0.110% + 1 kΩ0.052% + 500 Ω200.0000 MΩ100 Ω100 nA0.655% + 10 kΩ0.349% + 5k Ω>200.0000 MΩ 5-User definedSource IACC + Meas. VACCMeas. IACC + Meas. VACCTemperature Coefficient (0°-18°C and 28°-50°C)±(0.15 × accuracy specification)/°C.Source Current, Measure Resistance ModeTotal uncertainty = Isource accuracy + Vmeasure accuracy (4-wire remote sense)Source Voltage, Measure Resistance Mode Total uncertainty = Vsource accuracy + Imeasure accuracy (4-wire remote sense).Guard Output Impedance0.5 Ω (DC) in ohms mode.Notes1. All specifications are guaranteed with output ON.2. Accuracies apply to 2- and 4-wire mode when properly zeroed.3. 6.5 digit measure resolution4. Source readback enabled. Offset compensation ON.5. Source Current, Measure Resistance or Source Voltage, Measure Resistance only. For best measurements, use rear panel triax connectors.Operating CharacteristicsMax. Output Power20 W, four-quadrant source or sink operation.Source LimitsVsource: ±21 V (≤ 1 A range), ±210 V (≤ 100 mA range).Isource: ±1.05 A (≤ 20 V range), ±105 mA (≤ 200 V range).Overrange105% of range, source and measureRegulationVoltage: Line: 0.01% of range. Load: 0.01% of range + 100 μV.Current: Line: 0.01% of range. Load: 0.01% of range + 100 pA.Source Limits Voltage Source Current Limit: Bipolar current limit set with single value. Min. 10% of range.Current Source Voltage Limit: Bipolar voltage limit set with single value. Min. 10% of range.V-Limit / I-Limit AccuracyAdd 0.3% of setting and ±0.02% of reading to base specification.OvershootVoltage Source: <0.1% typical (full scale step, resistive load, 20 V range, 10 mA I-Limit.Current Source: <0.1% typical (1 mA step, RLoad = 10 kΩ, 20 V range).Range Change OvershootOvershoot into a fully resistive 100 kΩ load, 10 Hz to 20 MHz BW, adjacent ranges: 250 mV typical.Output Settling TimeTime required to reach 0.1% of final value after command is processed and output slew, 20 V range, 100 mA I-Limit: <200 μs typical.Maximum Slew Rate0.2 V/μs, 200 V range, 100 mA limit into a 2 kΩ load (typical).Over Voltage ProtectionUser selectable values, 5% tolerance. Factory default = none.Voltage Source Noise10 Hz-1 MHz (RMS): 2 mV typical into a resistive loadCommon Mode Voltage250 V DCCommon Mode Isolation>1 GΩ, <1000 pF.Noise Rejection (typical) NPLCNMRRCMRR 0.01-60 dB 0.1-60 dB 160 dB100 dB** Except lowest two current ranges ~90dB.Load Impedance20 nF typical (standard). Stable into 50 μF typical (High-C mode).High-C mode valid for ≥100 μA range s, ≥200 mV ranges.Max. Voltage Drop Between Force and Sense Terminals5 VMax. Sense Lead Resistance1 MΩ for rated accuracySense Input Impedance>10 GΩ.Guard Offset Voltage<300 μV, typicalGeneral Characteristics (default mode unless specified)Factory Default Standard Power-UpSCPI ModeSource Output ModesFixed DC Level, Memory/Configuration List (mixed function), Stair (linear and log).Source Memory List100 points max. (SCPI 2400 Mode only).Memory Buffer>250,000 readings. Includes selected measured value(s) and time stamp. Real-Time ClockLithium battery backup (3 yr. + battery life).Remote InterfacesGPIBIEEE-488.1 compliant. Supports IEEE-488.2 common commands and status model topologyUSB Device (rear panel, type B)2.0 Full Speed USBTMC.USB Host (front panel, type A)USB Host (front panel, type A)USB 2.0, support for flash drives, FAT32.EthernetRJ-45 (10/100BT).Digital I/O Interface:Lines6 Input/Output user defined for digital I/O or triggering.Connector9-pin female D.Input Signal Levels0.7 V (maximum logic low), 3.7 V (minimum logic high)Input Voltage Limits-0.25 V (Abs. minimum), +5.25 V (Abs. maximum).Maximum Source Current+2.0 mA @ >2.7 V (per pin).Maximum Sink Current-50 mA @ 0.7 V (per pin, solid-state fuse protected).5V Power Supply PinLimited to 500 mA @ >4 V (solid-state fuse protected).HandlerUser definable Start of Test, End of Test, 4 header bits.ProgrammabilitySCPI or TSP command setsTSP ModeEmbedded Test Script Processor (TSP) accessible from any host interfaceIP ConfigurationStatic or DHCPExpansion Interface The TSP-Link expansion interface allows TSP enabled instruments to trigger and communicate with each other.LXI Compliance1.5 LXI Device Specification 2016Display5 inch capacitive touch, color TFT WVGA (800×480) with LED backlight.Input Signal ConnectionsFront: Banana. Rear: Triaxial (3-lug).InterlockActive High Input.CoolingForced air, variable speedOver Temperature ProtectionInternally sensed temperature overload puts unit in standby modePower Supply100 V to 240 V RMS, 50-60 Hz (automatically detected at power up).VA Rating190 volt-amps max.AltitudeMaximum 2000 meters above sea level.EMCConforms to European Union EMC DirectiveSafetyNRTL listed to UL61010-1 and UL61010-2-30. Conforms with European Union Low Voltage Directive.VibrationMIL-PRF-28800F Class 3 Random.Warm-Up1 hour to rated accuraciesDimensionsWith bumpers and handle: 106 mm high × 255 mm wide × 425 mm deep (4.18 in × 10.05 in × 16.75 in).Without bumpers and handle: 88 mm high × 213 mm wide × 403 mm deep (3.46 in × 8.39 in × 15.87 in.)WeightWith bumpers and handle: 4.04 kg (8.9 lbs.).Without bumpers and handle: 3.58 kg (7.9 lbs.).EnvironmentOperating: 0° to 50 °C, 70% R.H. up to 35 °C. Derate 3% R.H./°C, 35° to 50 °C.Storage: -25 °C to 65 °C.Accessories SuppliedTest Leads, USB Cable, Ethernet/TSP Cable, Interlock Adapter, Power Cord, Quick Start GuideTech SpecsTest Equipment General AttributesCountry of OriginChinaShipping Height10.50 INShipping Length22.25 INShipping Width13.00 INPackaging & Shipping As an important international instrument sales platform, our company has the authorization qualifications of many international first-line brands. Relying on the advanced digital information management platform and international procurement platform, we provide more than 100,000 instruments, industrial MRO products, industrial products and spare parts to global customers. Our business scope: industrial testing, non-destructive testing, gas testing, electrical testing, laboratory testing, water quality testing, environmental testing, medical testing... So far, we have become an important partner of many global top 500 companies and well-known local Chinese companies. Create an efficient supply chain system to provide customers with strong supply guarantee.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...