IPDB › China Industry › Instruments & Meters
China, Chinese Single Channel Thermal Meter W Series1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Weighing Measuring ApparatusWeight IndicatorSimple Counting FunctionSimple Aninal Weighing Mode
Bengbu Sun-moon Instrument Institute Co., Ltd.
Preview:
Product Description specificationsPower supply voltage AC power supply 100-240 V AC 50/60 HzAC/DC power supply 10-24V AC 50/60 Hz; 10-24V DCPower consumption of AC power supply below 7 VAAC/DC power supply AC: below 6 VA; DC: Below 5WThe allowable voltage variation range is 90%~110% of the power supply voltageInsulation resistance ≥ 100M Ω (500V DC MEGA reference)Insulation strength 2000V AC (test conditions: 50/60Hz, 1 minute)Anti interference IEC61000-4-2 (electrostatic discharge), Class IIIIEC61000-4-4 (Electrical Fast Transient Pulse Group), Class IIIIEC61000-4-5 (surge), Class IIIProtection level IP65 (product front panel protection) (GB/T42-2008)Operating environment temperature -30~60 oC (storage: -40~65 oC)Environmental humidity of 35-85% R ? H, no condensationInstallation location indoor, height < 2000m Optional specificationsAlarmOutput 160 × 80 size T1~T4 1-4 alarm relay outputs, both normally open and normally closed dual contact 250V AC/3AResistive load96 x 96 size T1~T2 1-2 point alarm relay output, both normally open and normally closed dual contactsT3~T4 3-4 point alarm relay outputs, all of which are single normally open contacts96 × 48 size T1~T2 1-2 point alarm relay output, both normally open and normally closed dual contactsT3 3-point alarm relay output, single normally open contactT4 4-point alarm relay output, with the first 3 points being single normally open contacts,The fourth point is a normally open+normally closed dual contact72 x 72 size T1~T2 1-2 point alarm relay output, 1 point normally open+normally closed dual contact; 1-point normally open contactT3 3-point alarm relay output, 1 point is normally open+normally closed dual contact, and the other 2 points are single normally open contacts48 × 48 size T1~T2 1-2 alarm relay output, 1 point is normally open+normally closed contact, and the other point is normally open contactAnalog output A1 current output (4-20) mA, (0-10) mA, (0-20) mA photoelectric isolation,Resolution: 1/10000, load capacity: 600 ΩA2 voltage output (0-5) V, (1-5) VA3 voltage output (0-10) VcommunicationInterface MS1 RS232 interface photoelectric isolation,Response time: less than 500 μ S (measured value)Communication protocol selected through software(TCASCII or Modbus RTU)MS2 RS485 interfaceExternal supplyPower supply B1 24V ± 5% below 50mAB2 12V ± 5% below 50mA
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...