IPDB › China Industry › Industrial Equipment & Components
China, Chinese Air Source Heat Pump with Floor Heating and Cooling1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
HeatingRefrigeration Temperature ControlHeat PumpHeat PumpAir to Water Heat Pump
Shenzhen Eurostars Technology Co., Ltd.
Preview:
Product Description 1.Application of Air Source Heat Pump--Eurostars EVI air source heat pumps are designed for house heating and cooling. User can change the working mode by operating the controller. Compressor starts/stops according to return water temperature. When all rooms reach preset temperature by room thermostat, heat pump will be turned off through linkage switch.--Wide Range of Applications: these EVI low temperature heat pumps could meet the heating and cooling requirements of different places, such as villas, houses, schools, factories, hotels, hospitals, spa centers, sauna centers, greenhouses, flower gardens, farms, etc. 2.Eurostars Air Source Heat Pump Features:--1. Working condition ranges from -25C to 43C;--2. Emerson EVI scroll compressor--3. Water HE: adopt plate type heat exchanger or tube in shell heat exchanger--4. Automatically defrosting function--5. Automatic multiple protections and breakdown self-check function--6. Adopt multifunction controller(circuit board, LCD panel, temperature sensors)Technical details:--1. Compressor insulation for reducing noise--2. Cabinet insulation for reducing noise--3. Anti-vibration pad of compressor--4. Plastic pad of heat exchanger bracket--5. Thick insulation of heat exchanger to reduce heat loss--6. Thick insulation of gas pipe to reduce heat loss--7. Each wire line use different code, easy to repair--8. Wiring diagram and error code be included in manual, convenient to install and repair3. Air Source Heat Pump Technical DataAir Source Heat Pump Unit(EVI Low Ambient Temp.Type) (Heating&Cooling)ModelESSA-05LHNESSA-05LHNESSA-05LHNESSA-05LHN2.5ES3ES4.5ES5ESWorking modeHeating&CoolingPower supply220V/50HZ380V/50HZ220V/50HZ380V/50HZHeatingAir DB/WB:7oC/6oC,water In/outlet:40oC/45oCHeating capacity (kW) 7.68.414.015.2Input power(kW) 2.322.584.384.75Current(A) 11.14.721.08.7COP(W/W)3.283.263.203.20Water flow(m3/h)1.71.93.13.4Air: -10oC/ ,Water In/outlet:40oC/45oCHeating capacity (kW) 5.325.889.810.64Input power(kW) 2.202.454.164.51COP(W/W)2.412.402.362.36Air: -20oC/ ,Water In/outlet:40oC/45oCHeating capacity (kW) 4.04.47.48.0Input power(kW) 2.092.333.954.29COP(W/W)1.911.891.861.86Air: -25oC/ , Water In/outlet:40oC/45oCHeating capacity (kW) 3.94.26.47Input power(kW) 2.352.524.404.30COP(W/W)1.661.671.451.63CoolingAir DB/WB:35oC/24oC,water In/outlet:12oC/7oCCooling capacity (kW)6.87.612.613.7Input power (kW)2.392.664.514.89Current (A)11.44.821.68.9COP(W/W)2.862.842.792.80Water flow (m3/H)1.51.72.83.1 ModelESSA-10LHNESSA-10LHNESSA-10LHNESSA-15LHN5.5ES7ES2*5ES2*7ESWorking modeHeating&CoolingPower supply220V/50HZ380V/50HZ380V/50HZ380V/50HZHeatingAir DB/WB:7oC/6oC,water In/outlet:40oC/45oCHeating capacity (kW) 17.519.030.440.8Input power(kW) 5.465.949.512.75Current(A) 26.110.817.323.2COP(W/W)3.23.23.23.2Water flow(m3/h)3.94.26.89.1Air: -10oC/ ,Water In/outlet:40oC/45oCHeating capacity (kW) 12.2513.321.2828.56Input power(kW) 5.195.649.0312.11COP(W/W)2.362.362.362.36Air: -20oC/ ,Water In/outlet:40oC/45oCHeating capacity (kW) 9.210.016.021.4Input power(kW) 4.935.368.5711.51COP(W/W)1.861.861.861.86Air: -25oC/ , Water In/outlet:40oC/45oCHeating capacity (kW) 7.591419Input power(kW) 5.105.808.6012.00COP(W/W)1.471.551.631.58CoolingAir DB/WB:35oC/24oC,water In/outlet:12oC/7oCCooling capacity (kW)15.817.127.436.7Input power (kW)5.626.129.7913.13Current (A)26.911.217.823.9COP(W/W)2.802.792.802.80Water flow (m3/H)3.53.86.18.2 ModelESSA-20LHNESSA-30LHNESSA-40LHN 4*5ES4*7ES4*9ES Working modeHeating&CoolingPower supply380V/50HZ380V/50HZ380V/50HZ HeatingAir DB/WB:7oC/6oC,water In/outlet:40oC/45oCHeating capacity (kW) 60.076.0115 Input power(kW) 18.723.7635.9 Current(A) 34.143.365.5 COP(W/W)3.213.203.20 Water flow(m3/h)13.417.025.7 Air: -10oC/ ,Water In/outlet:40oC/45oCHeating capacity (kW) 4253.280.5 Input power(kW) 17.7722.5734.11 Current(A) 2.362.362.36 Air: -20oC/ ,Water In/outlet:40oC/45oCHeating capacity (kW) 31.539.960.4 Input power(kW) 16.8821.4432.40 Current(A) 1.871.861.86 Air: -25oC/ , Water In/outlet:40oC/45oCHeating capacity (kW) 2838 Input power(kW) 17.2024.00 Current(A) 1.631.58 CoolingAir DB/WB:35oC/24oC,water In/outlet:12oC/7oCCooling capacity (kW)54.068.4103.5 Input power (kW)19.2624.4736.98 Current (A)35.144.667.4 COP(W/W)2.802.792.80 Water flow (m3/H)12.115.323.1 4.Air Source Heat Pump Main Components Introduction5. EUROSTARS Heat Pump Range:(1) Water source heat pump(2) Geothermal source heat pump(3) Air source heat pump, including swimming pool heat pump(4) EVI air source heat pump (5) Split heat pump(6) DC Inverter heat pump6.About USWe, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services; which be always here to provide following service:1). Project system design;2). Technical support;3). Manufacturing production;4). Delivery;5). Installation;6). Test and commissioning;7). Repair and maintenance;8). After sale service,etc7.FAQQ:When in cold winter, can the heat pump unit work properly?Of course. Regarding our air source heat pump unit features intelligent auto-defrosting function, which ensure the heat pump to work in the low temperature by sensing the outdoor temperature, evaporator fin temperature and time of working automatically.Q:Why it can work at -25oC?Because of the Enhanced Vapor Injection (EVI) technology from Copeland compressor, EUROSTARS designed EVI gas piping system and controlling system, make EVI air source heat pump can work stably in the low temperature condition.8.Customer visit us9.Air source heat pump delivery or container loading10.Installation instruction or installation photo, project photosA,Place selection of installation Heat pump 1). Heat pump should be installed in a large space, and have good air flow condition. 2). Air inlet and outlet must be a clear road, the distance from barrier to inlet and outlet must be longer than 2m. 3). Set drain ditch or drain outlet, so that can drain water easily. 4). The installation base or bracket must be firm, make sure heat pump work balancely. 5). Make sure heat pump is vertical, can't be slanted. 6). Don't install heat pump at the place in where there is plenty of pollutional and corrosive gas or sand or fallen leaves. 7). The installation place can't be near inflammable, flammable thing or fire. 8). Installation:---The installation base can be concrete construction, or steel bracket, and must use anti-vibration rubber pad, And the surface should be smooth.---The design of installation base can be according to heat pump weight.---The heat pump bottom should be fixed by bolt.B,Pipe connectionThe drain pipe and overflow pipe should be installed near drain ditch or drain outlet, easy to drain, and install drain water valve on drain pipe before magnetic valve there should be service valve on water pipe. If use plastic pipe (such as PPR pipe or ABS pipe), users should consider pipe expand and contract problem between heat pump and water tank. Water supply valve and cut-off valve maybe need insulation (according to local weather condition),avoid frost crack.C,Water pipe system installationWater pipe should be straight, and the arrange should be reasonable, reduce bend as little as possible. Reduce the water pipe resistance.There can't be leaking at any place of pipe.After all equipments and pipes installation finished, users should test water pressure, and drive air out, drain dirty out, make sure water cycle system is clean. After confirm there is not any problem, then insulate all hot water pipes.D,Power supply wiring 220V heat pump use single phase power supply, 380V heat pump use three phase power supply, wire line is 3phase 4lines, A B C connects live line, N connects null line, E connect earth. Be sure not to connect N line to live line of power supply. 1).When repairing, please turn power supply at "off" side. 2).Power supply connecting process:make sure a equipment power supply is cut off before its installation is finished. Install power supply switch at suitable place, Use rubber hole for wiring line in electric box.Power supply demand:220V rated voltage±10%380V rated voltage±10%frequency:50Hz rated frequency±2% 3).if power supply fluctuation is out of demand, please don't start your heat pump.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...