IPDB › China Industry › Instruments & Meters
China, Chinese Macylab Emission Spectrum Icp Oes Oil Metal Analysis Lab Instruments Icp Spectrometer1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Analysis InstrumentLiquid AnalyzerIcp-OesIcp Spectrometer
Macylab Instruments Inc.
Preview:
Product Description Product Description Petrochemical Inductively Coupled Plasma Optical Emission Spectrometer(icp6800s) is A Professional Instrument For The Petrochemical Industry Launched By Macylab Instruments. It Can Be Used To Determine More Than 30 Elements In Crude Oil, Mainly For Fe.na.mg.ni. V.ca. Pb.mo.mn.cr.ca.ba.as; Also Can Be Used To Measure Iron, Manganese, Lead, Silicon In Gasoline ,and The Wear Elements Of Additive In Lubricating Oil, It Also Can Be Applied For Multielement Determination In Base Oils; For The Determination Of Sodium In Formaldehyde And The Determination Of Oil Field Tracer.Product Parameters Application EnvironmentCONTENT RANGEShipping/Storage Ambient Temperature 15oC-25oCShipping/Storage Relative Humidity ≤70%Atmospheric pressure 86-106 kPaPower Supply 220±10V 50-60MHzWorking Humidity ≤70%Working Temperature 15oC-30oC Technical ParameterRFPower technical parameter:Circuit type: solid-state RF power supply, with function of automatchFrequency: 27.12MHz±0.05%Frequency Stability: <0.1%Power Output: 800W-1500WPower Output Stability: <0.3%Escaped RF radiation: 30cm away from the instrument, electric field: E<2V/m Sampling System Technical Parameter:Output working coil inner diameter :25mmTorque tube: Three concentric, external diameter 20mmCoaxial nebulizer:Outer diameter 6mmDouble barrel atomizing chamber: Outer diameter 34mm Gas Flow Controls1. Plasma Argon Flowmeter:(100-1000)L/h (1.6-16L/min)2. Auxiliary Argon Flowmeter:(10-100)L/h (0.16-1.66L/min)3. Carrier Argon Flowmeter(10-100)L/h (0.16-1.66L/min)4.Oxygen Flowmeter:(0-100)ml/min (30-50ml/min) 5.Pressure Maintaining Valve(0-0.4MPa)6.Cooling Water:Temperature: 20-25oC, Rate of Flow>5L/min, Hydraulic Pressure>0.1MPa SpectrometerOptics:Czerny-Turner typeFocal length: 1000 mmGrating: Ion Beam Etching Holographic Grating, 4320L/mmReciprocal linear dispersion: 0.26nm/mmResolution:≤ 0.005nm (4320 line grating)Wavelength range: 4320 line grating:(180nm~435) nmMinimum pace of stepping motor: ≤0.0006 nmExit Slit:10μm;Entrance Slit:8μm Photoelectric Converter PerformancePhotomultiplier tube specification: R293Negative HV on PMT: 0-1000V;Stability: <0.05% Refrigeration SystemRefrigerating Swirling Fog Chamber:The use of imported silica gel collection technology can make the temperature drop to 20 degrees below zero Overall PerformanceWavelength range of scanning: 185nm~435nm(4320L/mm line grating)Repeatability: RSD(Relative Standard Deviation)≤1.5%Stability: RSD(Relative Standard Deviation) ≤2%Detection Limits (μg/L):Direct injection sampling and measure iron(Fe), manganese(Mn), lead(Pb) and silicon(Si) in gasoline.Analysis results:ElementFeMnPbSiDetermination value/(mg/L)3.617.51.82.4RSD/%0.560.231.380.92 Standard Additionand Recovery Rate:NumberStandard Addition(mg/L)FeMnPbSi Determination value(mg/L)Recovery/%Determination value(mg/L)Recovery/%Determination value(mg/L)Recovery/%Determination value(mg/L)Recovery/%10.450.43696.90.468104.00.43296.00.465103.3 20.90.88798.60.913101.40.86896.40.919102.1 Our Advantages Quality1. Our products have good quality and very positive reputations in the market. 2. Customers are very happy with them and have a lot of good comments about our intruments and service.Delivery Time1. We can get them ready 3-5 days after order confirmation for small orders. 2. For big quantities, need to be confirmed.3. In most cases, fast delivery is guaranteed.Technical Support1. We have service manual. If not, detailed documents or videos will be provided.2. We can provide online training in our factory.3. We can have video conference at any time.Aftersales Support1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.2. Within warranty, we will solve the problem for you with no charge(except for consumables).3. You can call, text or email us at any time. We have good English speakers.Warranty TimeOne year and extendable One-stop ShoppingCertifications ExhibitionCompany Profile Macy(China) Instruments Inc is part of Shanghai Macylab Instrument Inc, is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical instruments ,Macy constantly develop advanced products that enable Macy to become a high-quality instrument resource supplier and leader. Established in Shanghai in 2012, Macylab Instruments Inc. has three R&D(research and development)and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries,The company's main products are ultraviolet visible spectrophotometer, atomic absorption spectrometer, atomic fluorescence photometer, ICP-AES/ICP-MS, inductively coupled plasma emission spectrometer, ultra micro spectrophotometerFAQ Q1: Why choose Macy Lab?A1: Professional manufacturer with more than 10 years experienceMainly exported to the European and American markets, and we are also involved in other markets.Q2: Are you a factory or a trading company?A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.Q3: OEM , ODM acceptable or not?A3: Absolutely, yes.Q4: What can i get the price?A4: Usually we quote within 12 hours after we get your enquiryQ5:What are your Delivery terms?A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.Q6: What about the after-sale service?A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.Q7: What about the M.O.Q?A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.Q8: Sample order is OK?A8: Sample order is no problem.Q9: What' s kind of shipment for customer choosing?A9: Usually ship by sea, by air.We can also provide reasonable solutions according to your transportation requirements.Q10: Are your operation keypad, interface, software and manual in English version?A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.Q11: What areas and applications can it be used?Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.Q12: Which payment can be acceptable ?A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.Q13: What is the delivery time?A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.Q14: Can I get a sample?A14: Yes,please contact our staff for more information.Q15: How about OEM and ODM?A15: More than 10 years experience in OEM and ODM.Q16: What kinds of models do you make ?A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MSQ17: What standard accessories are included?A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.Q18: Is PC software included?A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.Q19: Why the reading is red and reach its maximum value 3.00Abs?A19: Probably you use the glass cuvette in UV range.Q20: Why the wavelength calibration or self checking fail?A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.Q21: Why is the reading is not as accurate as before?A21: Do the wavelength calibration before testing or restore the device to its default factory settings.Q22: Why PC software can not be installed successfully?A22: Close your anti-virus software on the computer and do it again.Q23: Why the software can not be connected successfully?A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.Q24: Can the data transferred to USB or PC?A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.Q25: Why the Abs value is negative(lower than zero).A25: Do the blanking or change the reference sample. Please Contact Us
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...