IPDB › China Industry › Instruments & Meters
China, Chinese Fuootech FT-2010SD Dga Analysis System Oil Chromatographic Analyzer Transformer Oil Gas Chromatography Analyzer1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Analysis InstrumentChromatographySpectroscopy InstrumentOil Chromatographic AnalyzerChromatographic Analyzer
Chongqing Fuootech Oil Purifier Technologies Co., Ltd.
Preview:
Product Description Series FT-2010SD DGA Analysis System Series FT-2010SD Power system Dedicated Insulation Oil and Gas Chromatography Analysis SystemFT-2010SD Power system Dedicated Insulation Oil and Gas Chromatography Analysis System runs by computer automatic control, all-keyboard operation and large-screen liquid crystal display according to the requirements of power system "dissolved gas component determination in insulation oil (chromatography)", and is characterized by high-precision temperature control, stable and reliable performance, high sensitivity, good reproducibility and so on. The analyzer adopts double-pillar parallel shunt system ,equipped with TCD, double FID and methane conversion oven, and could achieve total analysis of nine components (H2, O2, N2, CH4, C2H2, C2H4, C2H6, CO, CO2) of dissolved gas in insulation oil by one time. The analyzer can be employed for internal fault detection of power system oil and gas equipments, cooling medium analysis of hydrogen-cooled generators, impurity analysis of sulfur hexafluoride, the boiler flue gas analysis, gas analysis and environmental monitoring analysis. Due to its employment not only for special analysis, but also for general analysis, the analyzer becomes the most effective gas analytical instrument in petroleum, chemical engineering, mining and other systems. Major Characteristics: 1. Computer-keyboard operation, easy to operate.2. High precision and sensitivity, good reproducibility3. Stable and reliable analyzing performance4. Automatic analysis process, simple operation5. Large LCD screen6. Test Standard: complies to GB7252-2001, and ASTM D2887standard.1. Main technical specification:1.1 Temperature ControlTemperature range Column chamber: room temperature +15oC ~ 399oCVaporizing chamber: room temperature +30oC ~ 399oCConversion furnace :room temperature +30oC ~ 399oCThermal conductivity detector: room temperature +30oC ~ 399oCHydrogen flame detector :room temperature +30oC ~ 399oCTemperature control precision: ±0.1oC1.2 Thermal conductivity detectorSensitivity: minimum detectable concentration of hydrogen≥5μl/LNoise: ≤0.05mvDrift: ≤0.15mv/30min1.3 Hydrogen Flame DetectorMinimum detectable concentration of hydrocarbon ≥ 5 μl/LMinimum detectable concentration of CO,CO2 ≥ 5 μl/LNoise: ≤ 0.05 mvDrift: ≤ 0.15 mv/30min1.4 Whole machine start-up time: less than 3 hours2. Main performance characteristics:2.1 Computer-keyboard operationThis realizes five heating zone temperature control, detector control, over-temperature protection, "zero" degree protection, air break protection and other functions, so as to protect the chromatographic column and thermal conductivity rhenium tungsten filament most effectively.2.2 Large-screen liquid crystal displayIt could display a large amount of information intuitively and clearly.2.3 Advanced chromatography processBased on only one injection and three-detectors analytical process, the analyzer greatly increases detection sensitivity of hydrocarbon gas. Double hydrogen flame setting also reduces the detection impact caused by the gas content differences.3. Working conditions3.1 Normal instrument working conditionsEnvironmental condition:5oC ~ 35oCRelative Humidity:≤80%Power supply:220V±10% 50Hz±0.5Hz3KW power provided. No strong electromagnetic interference, corrosive gas and strong shock in the surroundings.3.2 Gas source Air purity: ensure the purity of carrier gas and hydrogen is more than 99.99%, the air to be used is purified and air generator function in dust, oil and water removal. Output pressure of steel cylinder relief valve: nitrogen 0.35MPa, hydrogen 0.25MPa, air 0.35MPa Please replace steel cylinder timely when output pressure fell below 2MPa.3.3 Ground wire To ensure personal safety and instrument performance, the instrument must be reliably linked to the land. It is suggested to bury the ground wire in the soil 1 meter below.PACKING & SHIPPING & PAYMENT
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...