IPDB › China Industry › Instruments & Meters
China, Chinese Sr2806fn Coating Thickness Gauge1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Analysis InstrumentOther Analysis InstrumentsCoating Thickness MeterGloss Meter
Shanghai Total Industrial Co., Ltd.
Preview:
Product Description Application:car's paint thickness testingpaint thickness testingSR2100 Coating Thickness GaugeDescription:This gauge is ultra low cost coating thickness gauge and can mainly be used to measure paint coating thickness. It is used for non-destructive coating thickness measurement of non-magnetic coatings, e.g. paint, enamel, chrome on steel, and insulating coatings, e.g. paint and anodizing coatings on non-ferrous metals.Features:Ultra low costEasy to do zero calibrationPower off automaticallyLow battery indicationAutomatically detect the substrates typeMulti-point calibration open to userSpecifications:ModelSR2100ProbeF-Probe & N-ProbeMeasuring PrincipleMagnetic induction & Eddy CurrentsMeasuring Range0 to 2000umAccuracy± (2%+0.02mm)Resolution0~499(1um) 500um~2000um(0.01mm)Calibrationzero point calibrationUnitsum , mm, milMaximum Measuring RateTwo readings per secondPower SupplyTwo 1.5V AAA batteryOperation EnvironmentTemperature: -10 to 50°CStorage EnvironmentTemperature: -20 to 70°CStandard CertificationROHS , CEDimensions89mm*49mm*21mmCase Material And WeightABS, 45g SR2801FN Coating Thickness GaugeFeature: -F/NF 2 in 1 type -Has CE marking, conforms with the essential health and safety requirements set out by the European Directives -The F type probe for measuring the thickness of non-magnetic coating on Ferromagnetic base (e. G. Iron, nickel and more), like plating layer, lacquer layer, porcelain enamel layer, phosphate layer, copper/aluminum and some ally tiles papers and others. -The NF type probe for measuring the thickness of any non-magnetic coating on Non-Ferromagnetic metal base (aluminum, brass, stainless steel, etc. ), like anodizing, varnish, paint, enamel, plastic coating, power layers, and others. -Microcomputer based, auto-detection, no damage to the coating surface. -Metric/imperial system selectable, Auto power off. -10 points value memory. -Flip LCD display-Suitable for the laboratory, Powder Coating Companies, Manufacturing Companies, Paint Suppliers, Manufacturing Companies, Steel and Aluminum Refinishing, Automobile Dealers, Auto Auctions, Body Shops, Auto Detailers and any company needing a highly accurate measurement of the dry coating thickness and can be used even in harsh field conditions.Specification:Range: 0 - 1250um; M, 0 - 50mil Resolution: 1um0.1mils Accuracy: +/-(3%+2um) or +/-(3%+0.1mils) Modes: Single & Continuous Battery Indicator: Low battery indicator Metric/ Imperial: Convertible.Memory: 10 pointsBattery: 1.5V x 1, AAA size (not included) Packing: Spectacle case, BandboxSR2802FN Coating Thickness GaugeFeatures-F/NF 2 in 1 type Easy Holding : Well designed housing and shape fits the hand comfortablyNice Viewing : Dot Matrix display with two colors switchable (Black letter on white background and Green letter on black background). Reading is clearly visible on any conditions and angles .Convenient Measurement : Simultaneously display the current reading in um/mil,Max, Min and Average value will be on the bottom of the screen . Makes the measurement more efficient andcomparable.Easy Calibration: Calibration is unnecessary for mostconditions, if need, only place the probe on the uncoatedsurface and press "ZERO" , or adjust the reading by "+" . "-"Basic FunctionsAuto switch on by place the the probe on a surface ,And Auto goes off after 30s of inactionFlip displayThe MAX . MIN and AVE value are clearableLow voltage indicatorSpecification Range0-1250um, 0-49mils Accuracy ±(2um+3%H), H is standard thickness Operation Temperature -10°C-60°C Storage Temperature 0-40°C Dimensions 109x45x27mm Weight 150With battery Power Supply 1.5V AAA X 2 Included Accessories Carry case; instruction manual; Calibration shims , uncoated substrates Standard Individual Packing Gift box with carrying case inside SR2802FN+ Coating Thickness GaugeFeatures:Easy Holding: Well designed housing and shape fits the hand comfortably Nice Viewing: DOT Matrix display with two colors switchable (Black letter on white background and Green letter on black background ). Reading is clearly visible on any conditions and angles. Convenient Measurement: Simultaneously display the current reading in um/mil, Max, Min and Average value will be on the bottom of the screen. Makes the measurement more efficient and comparable. Easy Calibration: Calibration is unnecessary for most conditions, if need, only place the probe on the uncoated surface and press "ZERO", or adjust the reading by "+" " -" Basic Functions:1. Auto recognize the substrate of Ferrous and Non-Ferrous 2. Auto switch on by place the the probe on a surface, And Auto goes off after 30s of inaction 3. Flip display 4. The MAX. MIN and AVE value are clearable 5. Low voltage indicator Specification:Rang: 0-1250μm, 0-49mils Accuracy: +/- (2μm+3%) Dimensions: 109*45*27mm Power Supply: 1.5V AAA * 2 Weight: 150 with battery Included Accessories: Carry case; Instruction manual; Calibration shims, uncoated substrates Standard Packing: Gift box with carrying case inside SR2806FN Coating Thickness GaugeFeatures:-Large and clear TFT Screen(160x128TFT)-Auto recognition of the substrate material (Fe or NFe)-Metric/imperial switchable (mil/um switchable)-Single / Continue measurement selectable-Flip display-99 data memory -Simultaneously displays 5 readings: (easy for data analysis and comparison) Measuring Reading , Average Reading , Max. Reading , Min. Reading and Standard Deviation.Specification:Range: 0 - 1250um; 0 - 50mil (Max. add to 2000um/80mil)Resolution: 1um, 0.1mils Accuracy: ± (3%+2um), ± (3%+0.1mils)Response time: 0.6 secSensor type: Fe & NFe 2 in 1 General Information:Battery: 1.5V*2 AAA sizeDimension: 119*52*28mmWeight:80gPacking: carrying caseSubstrate blocks (steel*1pc, Aluminum*1pc)Calibration foils*1setEnglish manual SR2806 Coating Thickness GaugeFeatures:1. Non-magnetic coatings (e.g. paint, zinc) on steel2. Insulating coatings (e.g. paint) on no-ferrous metals3. No-ferrous metals coatings on insulating substrates4. Menu operation system5. Two measuring mode: CONTINUE and SINGLE mode6. Two working Mode: DIRECT and GROUP mode7. Statistic Display: AVG, MAX, MIN, NO., S.DEV8. One point calibrating, two points calibrating and basic calibrating easily9. Memory for 400 readings(80 DIRECT and 320 GROUP readings)10. Delete single readings and all group readings easily11. High alarm and Low alarm for all working mode12. Low battery, error indication13. USB interface for PC software (windows 98/2000/xp/vista)Accessories:Two "AAA" batteries, USB cable, CD, Calibration Iron, Calibration Aluminum, Precision Standard, gift box with carrying case.Specifications:Sensor probeFNWorking principlemagnetic inductionEddy current principleMeasuring range0~1250um0~1250umGuaranteed tolerance (of reading)(+/- 3%+1)um(+/- 3%+1.5)umLow range Precision0.1um0.1umMinimum curvature radius1.5mm3mmDiameter of Minimum area3mm5mmBasic critical thickness0.5mm0.3mmSize(HxWxD)113.5mm x 54mm x 27mmWeight110g
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...