China, Chinese TUNKIA TK1320 Automatic Current Sensor Current Transformer Calibration System Comprehensive test bench with Software1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Electronic InstrumentCalibratorCurrent Transformer test benchCurrent Sensor test bench
Tunkia Co., Ltd.
Preview:
Product Description TK1320 Current Sensor Comprehensive Testing Device(The picture is for reference only, the actual product will be subject to delivery)1. SummaryTK1320 is a multifunctional device designed for testing the comprehensive performance of current sensors. It mainly consists of a DC high-current standard source, a high-frequency constant current source, a pulse current source, a sensor output quantity tester, and dedicated testing software. This device can conduct metrological performance testing, frequency response bandwidth measurement, and response time measurement for current sensors. When combined with specialized testing software, it can automate multiple testing procedures. 2. FeatureMetrology Performance Testing: High-current standard source and sensor output quantity tester.Frequency response bandwidth measurement: high-frequency current source + digital multimeter.Response time measurement: pulse current source + pulse shunt + multi-channel oscilloscope.Sensor auxiliary power supply and power consumption measurement.Mobile measurement and control consoleMultiple test positions (customizable)Special testing software3. Application☆ Metrology Performance Testing (Direct Measurement Method)Direct Measurement Method: The high current standard source of TK1320 outputs the primary current standard source I1 to the current sensor under test, and its secondary signal is measured by the sensor output power tester, that is, the ratio difference (or phase displacement) of the sensor under test can be calculated. This method is suitable for testing medium and low precision current sensors.High Current Standard Source: DC high current standard source can be configured according to user needs. The current output range is 300 A ~ 5 kA. The accuracy level can reach Class 0.02.Sensor Output Power Tester: voltage measurement range ±(10 mV ~ 12 V), current measurement range ±(1 mA ~ 1.1 A), DC measurement accuracy reaches 0.005 level.Sensor Auxiliary Power Supply: adjustable within the range of DC ±(5.0 V ~ 50.0 V).Multiple Test Positions (optional): To test multiple current sensors at the same time, multiple sets of sensor output power testers and auxiliary power supplies need to be configured at the same time.Special Test Software: Users can customize the test plan to complete test items including zero-point output error, full-scale output error, linearity error, hysteresis (hysteresis), repeatability error and accuracy, etc., and edit the test points of each item to achieve Automatic detection of current sensor metering performance. ☆ Frequency Response Bandwidth MeasurementUse a high-frequency constant current source with a standard digital multimeter to measure the frequency response bandwidth of the current sensor. If the sensor being tested is a current output type, a high-frequency coaxial shunt must be used to convert the secondary current I2 into a voltage signal U2 before connecting the digital multimeter to measure.High Frequency Constant Current Source: 1 mA ~ 10 A, DC ~ 1 MHz, stability 0.1%/min @ 1 MHz.Digital multimeter: A 6.5 digits (300 kHz) or 8.5 digits (1 MHz) digital multimeter can be selected according to the bandwidth of the sensor being tested.High Frequency Coaxial Shunt: nominal input current 100 mA, 1 A, nominal output voltage 1 V, frequency DC ~ 1 MHz, annual stability 18 ppm, AC/DC difference 30 ppm @ 1 MHz.Low Current Three-Way (Optional): It is convenient to connect two current sensors to be tested at the same time to achieve simultaneous detection and improve test efficiency. ☆ Response Time MeasurementA pulse current source is used, combined with a standard pulse shunt and a multi-channel oscilloscope, to measure the response time of the current sensor. The pulse current is connected to the standard pulse shunt and the current sensor under test, and then the secondary output signal waveforms of the two are viewed on the oscilloscope. And the rise time of the current sensor under test is compared to calculate the response time.Pulse Current Source: current amplitude 500 A, rise time 10 μs, accuracy class 0.5.Standard Pulse Shunt: test current 500 A, response time < 10 ns.Multi-Channel Oscilloscope (optional): measurement channels ≥2, measurement bandwidth ≥ 100 MHz.Through-Core Current Sensor Test Fixture (optional): current specification 500 A, multiple test locations, low inductance coaxial structure.4. Specifications4.1 DC High Current Standard SourceCurrent Output Range300 A ~ 5 kAMaximum Load Voltage3.5 VAccuracyClass 0.02Annual Measurement Uncertainty(k=2)0.015 %*RG+0.005 %*RDProgrammed Commutationexternal commutatorRipple Coefficient ≤ 0.5 %Current Overshoot≤ 10 %Protective Functionopen circuit protection, overload protection, overheating protection 4.2 Sensor Output Power TesterVoltage measurement range100 mV,1 V,10 V,manual or automatic range switching±(10 mV ~ 12 V)Current Measurement Range10 mA,100 mA,1 A,manual or automatic range switching±(1 mA ~ 1.1 A)Measurement Uncertainty (k=2)DC: 0.003%*RD + 0.002%*RGDisplay Digits7 decimal digitsTemperature Coefficient0.5 ppm/°C @ (0°C~40°C)Number of test positionsMultiple measurement channels can be provided according to the number of test positions4.3 Sensor Auxiliary Power Supply and Power Consumption MeasurementSupply VoltageDC ±(5.0 V~50.0 V) adjustableMaximum Load Capacity1 APower Consumption Measurement AccuracyClass 0.5Protective Functionopen circuit protection, overload protection, overheating protectionNumber of Test PositionsMultiple auxiliary power supplies and power consumption measurement channels can be provided according to the number of test positions.AC Power SupplyAC 220 V power supply can be added according to user needs 4.4 High Frequency Constant Current SourceCurrent Output Range1 mA ~ 10.5 AFrequency RangeDC,10 Hz ~ 1 MHzShort Term StabilityDC: 0.005%/minAC: 0.01%/min @ 10 kHz,0.05%/min @ 100kHz,0.1%/min@1MHzMeasurement Uncertainty(k=2)DC: 0.02%AC: 0.08% @ 10 kHz,0.5% @ 100 kHzMaximum Load Voltage7 Vrms 4.5 Pulse Current SourceCurrent Output Range500 APulse TypeUnipolar pulseMeasurement Uncertainty(k=2)0.5%Repeat Frequency10 Hz ~ 1 kHzPulse Width1 ms ~ 100 ms,Adjustment step 0.1 msRise/Fall Rate50 A/μsMaximum Load Voltage9 Vpk5. General SpecificationsWarm-up Time30 minutesWorking EnvironmentTemperature: 0°C ~ 40°CHumidity: 20%R·H ~ 85%R·H, no condensation.Others: No electromagnetic field interference.Storage EnvironmentTemperature: -20°C ~ 70°CHumidity: 10%R·H ~ 95%R·H, no condensation.Communication InterfaceRS232×1 6. Power Supply RequirementsS/NDevice NamePower supply typeMaximum power consumption1DC High Current Standard Sourcethree phase five wireAC 380 V ± 38 V50 Hz ± 2 Hz4 kW per 1 kA current source2Sensor Output Power Tester0.1 kW/set3Sensor Auxiliary Power Supply And Power Consumption Measurement Module0.2 kW/set4Pulse Current Source6 kW5High Frequency Constant Current SourceAC 220 V ± 2 V50 Hz ± 2 Hz0.5 kW Company Profile
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...