IPDB › China Industry › Instruments & Meters
China, Chinese Wdxrf Spectrometer for Cement Test Skyray Wdx200 Spectrometer1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Analysis InstrumentChromatographySpectroscopy InstrumentSpectrometerWdx Instrument Cement Analysis
Jiangsu Skyray Instrument Co., Ltd
Preview:
Product Description Product DescriptionInstrument introductionWDX 400 Compact Multi-channel X-Ray Fluorescence Spectrometer features for 10 fixed light diffraction channels, with 10 arbitrary elements defined by the users from Na to U being analyzed simultaneously. The standard ten elements configuration is Na, Mg, Al, Si, S, Cl, K, Ca, Fe, P or Ti(optional). The instrument is an ideal quality control choice for large and medium-sized enterprises. Higher X-ray power, higher measurement precision, more stable measurement data, higher excitation efficiency, lower limit of detectionProduct ParametersPerformance characteristicsa. reach adequate measurement accuracy with smaller power and equivalent measurement time; b. prolonged service life. c. fewer failures in high voltage supply, d. lower maintenance costs of the overall instrument,e. no wearing problem of goniometer as fixed channels adopted.f. Rapid and non-destructive analysis of powder sample and lump sampleg. Fast analyzer of compacted powder, fused beads and lump materialh. Multi-channel digital MCA has greatly improved the measurement efficiency, which benefits not only the instrument debugging and failure diagnosis but also enhances the measurement accuracy and stability.Technical specificationsHigh voltage supply: 400W (50KV8mA)X-ray tube: 400W thin Be end window X-ray tube made by Varian company, Rh anode (Pd anode optional) Measurable elements: 10 arbitrary elements from Na to U. Detector: gas flow proportional detector + sealed proportional detector; 10 paths 1024 channels independent pulse height analyzerVacuum system: independent pumping station for easy maintenance with highest vacuum lower than 5 Pa Gas flow system: high-accuracy gas density stabilizer with pressure stability up to ±0.003 KPa. MCA: MCA measures the peak of every element in real time, which is not only good for instrument debugging and failure diagnosis but also enhance its analysis accuracy and stability. AC 220V power supply: 1KVA AC purified stabilized voltage power supply Analysis accuracy: oη-1 (24 hours,percentage content) ≤0.05 %.Temperature control precision in constant temperature chamber: setting value+0.1°C.Standard configurations400W high-voltage power400W Be end window X-ray tube Gas flow proportional detector + sealed proportional detector10 paths of 1024-channel independent pulse height analyzerIndependent vacuum pumping structureHigh sophisticated flow density stabilizer Multi-channel MCA real-time detection system1KVA AC purified stabilized currentApplication fieldsBuilding materials (cement, glass, ceramic, etc) Steel Non-ferrous metals Minerals, Geography Chemical engineering Petroleum Quality inspection Commodity inspection ModelWDX-200Temperature control accuracy of constant temperature chambersetting value±0.1oCMeasurable elements10 arbitrary elements from Na to UAnalysis algorithmsempirical coefficient algorithm and theoretical a-coefficient algorithmAC220V power supply1KVAAC purified stabilized voltage power supplyHigh voltage supply200W(50KV4mA)12-hour stability of tube voltage & tube currentless than 0.05 %Vacuum pumpbiphase~220v, 2 litersIndustrial computerindustrial 104 computerAnalysis accuracy°n-1(24 hours, percent content)≤0.05 %Measurement time of single sample(including time for changing samples and vacuum pumping)≤3-5 minutesX-ray tube400W thin Be end window X-ray tube made by Varian company, Rh anode (Pd anode optional)Detectorgas proportional detector + sealed proportional detector, 10 path 1024 channel independent pulse height analyzerVacuum systemindependent vacuum pump station, easy maintenanceThe highest vacuum degreelower than 5 PaGas flow systemHigh Sophisticated Gas Density Stabilizer with pressure stability up to ±0.003 KPaAnalysis softwareequipped with software for two quantitative analysis algorithms: empirical coefficient algorithm and theoretical a-coefficient algorithm. With innovative technology of full spectrum analysis, every spectrum line can be timely traced and corrected, which greatly improves the repeatability and stability of quantitative analysis and also serves as intuitive evidence of instrument status diagnosis. Complete measures for self-diagnosis are supplied. In-built RS-232 serial communication protocol, TCP / lP protocol (S/ C based on Socket) and OPC protocol (OPC server) all offer ways to share data with DCS or Qcs system.Detailed Photos
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...