IPDB › China Industry › Instruments & Meters
China, Chinese UL 1973-2022 GB 38031-2020 ECE R100 External Fire-Fired Test Machine1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Test InstrumentBattery TesterTest MachineExternal Fire-Fired
Dongguan Hong Tu Instrument Co., Ltd.
Preview:
Product Description External fire-fired test machineProduct use:Battery pack external fire test machine is to simulate the battery pack or system installed on the electric car, electric car after high temperature ground or a flame of the ground of the ground, the battery pack or the system surface temperature rises suddenly, observe the battery pack or system in a short time, because the temperature may rise all kinds of conditions. It is a special testing instrument for power battery pack or system safety testEquipment composition:The battery pack fire test bench is composed of oil source, bench part, oil pan, cover plate, refractory brick, waterway system, oil circuit system, ignition system, control system, safety protection system, etcSatisfying standard:UL 1973-2022 Safety standard for energy storage battery systemGB 38031-2020 Safety requirements for power batteries for electric vehiclesGB / T 31467.3-2015- -Lithium-ion Power Battery Packs and Systems for Electric Vehicles- -Part 3: Safety Requirements and Test MethodsECE R100Experimental procedure:3.1 The test object is the battery pack or the system3.2 In the test, the size of the flat plate containing gasoline is 20cm above the horizontal size of the test object, not more than 50cm, and the height of the flat plate is not higher than 8cm above the surface of gasoline. The distance between the gasoline liquid level and the test object is set by 50cm, or the height from the ground of the bottom surface of the test object of the vehicle in no-load state, or water into the bottom of the flat plate is agreed by both parties3.3 Light the gasoline at least 3m away from the equipment under test. After 60s of preheating, place the oil pan under the equipment under test. If the oil pan is too large to move, move the bracket of the tested sample box3.4 The test subject was directly exposed to the flame for 70s3.5 Cover the cover on the oil pan. The test subject tests 60 Ss in this state or continues to be directly exposed to the flame for 60s as agreed by both parties3.6 Remove the oil pan and observe for 2h3.7 Requirements: the battery pack or the system has no explosion phenomenon. If there is a fire, it should be flameout within 2min after the fire source is removedProduct Parameter: product modelHT-CD-1123control methodComputer remote control + video surveillance; or PLC touch screen control (customizable)Pool sizeW3000*D2000*H1200mmLift method of battery pack (optional)One of the following options can be selected1. Cantilever lifting method2. Hoisting method of gantry aerial crane3. Lift mode of the lifting platform4. The load can be customized for 1t; 2t; 3t...Battery pack connection modeInstall the ring on the fixed hole of the battery pack, and then connect the ring with a flexible hookPool materialInsulation and corrosion-resistant material PP boardWater controlAutomatic addition, equipped with a solenoid valve and a water level switchAutomatic drainageDrainage pump accelerates automatic drainage controlMelt and stir thick saltThe pump automatically absorbs water and washes the crude salt, melting and stirring controlWater level height scaleThe height scale of the molten water level in the water tank can see the height of the water level intuitivelyOnline salinity detectionAutomatic online detection of saline concentration, convenient matching of saline concentrationRemote video surveillance (optional)Surveillance cameras are installed in the laboratory to monitor the test status by remote video. The camera is no less than 5 million pixels and has a 1080P resolutionSafety protection designOverload protection; with leakage protection device, water level limit, safety emergency stop switch, three-color light alarm indicatordevice power supplyAC380V50HZ3.0kW (4kW)Tank shape sizeW3250*D2250*H1500mmgross weight of equipmentAbout 2,500 kgInstallation conditions1. Ground load-bearing 1500 kg/m, dig drainage ditch around the ground equipment, drainage ditch section 300 * 300mm2. Laboratory space W7500 * D6000 * H5000mm3. Lighting system is installed in the laboratory with an illumination level of 200 lumens4. Equipped with fire water or tap water for battery packs for fire extinguishing5. A smoking cover is installed on the top of the test area to connect the smoke purification equipment, which is 4.5m away from the ground height and can not interfere with the aerial crane6. Design the explosion-proof pressure relief outlet and fill air outlet in the laboratory7. Equipped with cantilever crane need to dig pit W1500 * D1500 * H1500mm, buried into the cage, pouring and fixingWe treasure the value of good quality , reasonable price and efficient service with customer satisfaction . we expert ourselves in providing our customers the best suitable testing designs and high quality testing machines to make you the utmost profit Please feel free to contact us for any enquiries from our wide range of products
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...