IPDB › China Industry › Instruments & Meters
China, Chinese TMAXCN Brand 100V 60A Battery Charging&Discharging Machine for High Power Battery1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Test InstrumentBattery TesterCapacity Testing EquipmentCharge and Discharge Tester
Xiamen Tmax Battery Equipments Limited
Preview:
Product Description 100V 60A Battery Charging&Discharging Machine for High Power Battery Introduction:*Power battery simulation, C-rate test.*Life cycle test.*Power test, capacity test, energy density test.*Power battery virtual distribution: charge/discharge curve fitting, battery consistency test and evaluation.*High rate charge/discharge test.*Power battery, serial energy-storage battery module test: single cell voltage, Single cell temperature monitoring(high-voltage equipment). Features(some features required a customization): *High-performance charge/discharge test platform developed for high-power battery modules(or packages).*Adopting AC/DC,DC/DC Dual-level high frequency module design, combined with low temperature drift, high-performance multi-channel 24-bit analog-to-digital conversion chip(ADC) to achieve higher stabilize accuracy. *High-level power density system with multi-channel integration and capable for energy recovering.HMI operation, smart calibration.*Multiple adaption for BMS, supports the same/different charge and discharge ports, relay/MOSBMS solution, independent CAN and RS485 communication expansion, and DBC configuration.*Remote control available for host computer through Ethernet, channels parallel, pulse and driving simulation available. *Man-computer integration interface design, minimized system for easy-understand operating, customized setting available, automatic reminder for termly calibration. CE-6000 Specification1,Model1. Material codeCE-6002n-100V60A-H2,Channels information1. Channels quantityChannels quantity in one unit22. Main channelChannel featureConstant current source and constant voltage source dual closed loop control Channel control modeIndependent control Channel parallel connectionSupport max 4 channels parallel mode. Pulse and SIM tests will be disabled in channels parallel mode. 3,Power grid side parameters1.Input power AC380V±15% 50/60±5Hz2.Power factor ≥99%(Full load)3.THDi ≤5%(Full load)4.Input resistance ≥1MΩ5.Input power 14.1KW6.Input current 21.5A/single7.Overall system efficiency(Max) 90%8.Noise ≤65dB9.Voltage and current sampling Four-wire connection(same port for charging and discharging)10.Power control module type MOSFET11.Input power wiring method Three-phase-five wire system12.Power input protection Anti-surge, anti-silos, anti over or under frequency, anti over or under voltage, anti phase absence, etc.4,Functions and performances1. VoltageOutput rangeCharge:0V~100V Discharge:3V~100V Min discharge voltage3V Accuracy±0.02% of FS Resolution24bit2. CurrentOutput range0.3A~60A Accuracy(independent range)±0.05% of FS CV cut-off current60mA Resolution24bit3. PowerSingle channel output power6KW Whole machine output power12KW4. TimeCurrent response time≤3ms Current conversion time≤6ms Min. step time0.1s5. Charge/Discharge modesCharge/Discharge modesCCC, CVC, CC-CVC, CPC CCD, CVD, CPD, CRD Cut-off conditionVoltage, Current, ΔTime, Capacity, -ΔV6. SimulationChargeCurrent, Power DischargeCurrent, Power SwitchSupport continuous switching between charge and discharge Cut-off conditionTime, step line Steps file lines1,000,0007. Pulse ModeChargeCurrent ,power DischargeCurrent, Power Min pulse100ms Pulse countsUp to 32 Charge and discharge switchsupported Cut-off conditionVoltage, ΔTime8. DCIR DCIR by calculation9. Safely protectionSoftware protectionPower off data protection Offline mode function Safety protection conditions can be set, including:voltage lower limit ,voltage upper limit ,current lower limit ,current upper limit ,delay time, etc. Hardware protectionAnti-reverse connection, over-voltage, over-current, over-temperature, etc.5,Data management and analysis1. Step setting method Form editing2. Data reportRecording conditionsMinimum time interval: 10ms(connected with AUX channel:100ms) Minimum voltage interval: 0.2V Minimum current interval: 0.12A Recording frequency100Hz(connected with AUX channel:10Hz)3. Database MySQL database4. Data output Excel, Txt5. Curve type Templates available, customization supported6. Bar code scanning Support bar-code scanning function Management and traceability of historical data6,Communication1. Host computer communication TCP/IP protocol2. Communication port Ethernet3. Communication baud rate of the testers 1M4. Host computer communication baud rate 10M~100M adaptive5. Communication setup Set up a LAN(local area network) through switches and routers6. Communication expansion(optional) Support CAN, RS485 communication and BMS communication, with DBC configuration function7,Environmental requirements, dimension and weight1. Operation environment temperature -10oC~40oC(When the temperature is 25±10oC, the accuracy error caused by temperature change is less than 0.005% of FS per degree)2. Storage environment temperature -20oC~50oC3. Operation environment humidity ≤70% RH(no moisture condensation)4. Storage environment humidity ≤80% RH(no moisture condensation)5. Dimension W*D*H 600*800*900(mm)6. Weight about 111.1KG
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...