IPDB › China Industry › Industrial Equipment & Components
China, Chinese Venttk First-Class Ahu for Clean Room Hydronic Air Handling Unit1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Refrigeration EquipmentIndustrial Air ConditionerWater Cooled AhuDx Ahu
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Preview:
Product Description Product ParametersAir cooled direct expansion type air handling unitunit characteristicsModel: GT-ZKW-()DX203040506580100Cooling capacityKW10.115.320.325.532.338.652.0Heating capacityKW10.315.720.826.133.539.553.2Supply air volumeM3/h20003000400050006500800010000Margin blast pressurePa200250300300400400500Power3N-380V-50Hz Indoor unitBlowerTypeHigh efficient centrifugal fanKW0.550.751.52.23.03.05.5Chilled water coil(option)TypeHigh efficient copper tube aluminum finWater flow(m3/h)1.72.63.54.45.66.68.9Segment length(mm)300300300300300300300HeaterTypeStainless steel tubular electric heater/ Steam heat coil/ Hot water heat coilKW691218242430segment length(mm)300300300300400400400HumidifierTypeElectrode type/ Steam/ Electrothermic type/ Wet filmKW345881212segment length(mm)400400400400400400400Air filterTypePrimary filter G4( Middle filter F8 &Nanocrystalline carbon filter)NoisedB(A)60606162636365SizeL (mm)1800200020002100210022002400W (mm)730103010301030114013401340H (mm)78878811151115111511151420WeightKG140180320400580660800Outdoor unitModel: GT-WL-10152025354055Compressor ATypeHermetic Scroll ( Fixed frequency system)Quantity1111122Input power AKW3.44.86.38.09.812.716.1Compressor BTypeHermetic Scroll( Frequency conversion system)Quantity1111122Input power BKW3.34.66.27.79.712.615.6RefrigerantTypeR22/R407C/R410AModeThermal expansion valve/ Electronic expansion valveNoisedB(A)63636464656576SizeL (mm)85085098098098018801880W (mm)850850980980980980980H (mm)1080108010801080123410801080WeightKG130135150180220280320Connection Pipe diameterliquid pipe(mm)12.7(9.52)12.7(9.52)12.7(12.7)15.88(12.7)15.88(12.7)15.88*2(12.7*2)15.88*2(12.7*2)gas pipe(mm)15.88(12.7)19.05(15.88)19.05(15.88)28.6(22.23)15.88(12.7)22.23*2(19.05*2)28.6*2(22.23*2)Note:Cooling condition: indoor dry bulb/wet bulb 27/19 oC;Outdoor dry bulb/wet bulb 35/24 oC;Heating condition: indoor dry bulb/wet bulb 20/- oC;Outdoor dry bulb/wet bulb 7/6 oC;Air volume, pressure, power in the table is standard parameters. It can be separately designed according to customer's requirements;Chilled water coil as optional parts, according to the customer site requirements configured to double cold source unit;Heater, humidifier, heat recovery device as optional parts, according to the customer requirements configured to the specific formUnit standard USES G4 level filters, according to the customer requirements configured to the other forms;Unit length does not include the function section. Such as heating section humidification secition. Specific details please consult us;Air cooled split type air conditioning unit without refrigerant leaving the factory, refrigerant models need to indicated in the order;Noise data is measured 2 m in the front of the unit , 1.2 m high, when cooling under the standard air volume; Inside of bracket is R410A refrigerant type connection pipe diameter, the connection copper pipe between the indoor and outdoor unit should within 35 meters. Chilled water type air handling unitModel GT-ZKW-20406080100150200250300Air volume(m3/h)20004000600080001000015000200002500030000Outlet air pressure(pa)300300400500500600750750750Supply fan capacity(kw)1.11.52.245.511151518.5Cooling4 RowsReturn air(kw)12.223.935.9486090120150179water flow(m3/h)2.24.26.18.210.515.320.423.828.2all fresh air(kw)2243.86290112156210265310water flow(m3/h)3.87.71115.519.227.336.545.855pipe diameter (DN)2532404040506565806 RowsReturn air(kw)1730.145.26075113151188210water flow(m3/h)2.85.37.710.513.619.225.530.236all fresh air(kw)30.55888118150200288355420water flow(m3/h)5.11015.220.226.235.5497072.5pipe diameter (DN)3232404050656580808 RowsReturn air(kw)18.335.2537090132176220264water flow(m3/h)3.26.28.912.216.222.230.237.244.2all fresh air(kw)34.870101138178245332410500water flow(m3/h)5.81217.523.530.842.557.17185pipe diameter (DN)323240405065658080Heating2 RowsReturn air(kw)20426084108150200250300water flow(m3/h)0.81.92.63.74.66.58.71113all fresh air(kw)18385470100125180210280water flow(m3/h)0.81.72.43.24.55.57.81012pipe diameter (DN)2532404040405050654 RowsReturn air(kw)285680110140200250320380water flow(m3/h)1.22.43.54.86.391113.518.2all fresh air(kw)326290125150220300380450water flow(m3/h)1.52.73.85.46.89.513.516.219.5pipe diameter (DN)323240404050506565Function sectionoutside dimensionMixing sectionLength(mm)500500500550600800800800800Width(mm)9509501080125016001600200022002200Height(mm)9809801080125013201470168018802200Pre-filter sectionLength(mm)100100100100100100100100100Width(mm)9509501080125016001600200022002200Height(mm)9809801080125013201470168018802200Medium efficiency filter sectionLength(mm)500500500500500500500500500Width(mm)9509501080125016001600200022002200Height(mm)9809801080125013201470168018802200Cooling coil sectionLength(mm)60060070070070080080010001000Width(mm)9509501080125016001600200022002200Height(mm)9809801080125013201470168018802200Heating sectionLength(mm)300300300400400400400400400Width(mm)9509501080125016001600200022002200Height(mm)9809801080125013201470168018802200Humidifying sectionLength(mm)400400400400400400400400400Width(mm)9509501080125016001600200022002200Height(mm)9809801080125013201470168018802200Fan sectionLength(mm)50050090040011001400160017001850Width(mm)9509501080125016001600200022002200Height(mm)9809801080125013201470168018802200Current balance sectionLength(mm)400400500900500600600600700Width(mm)9509501080125016001600200022002200Height(mm)9809801080125013201470168018802200Sound deadening sectionLength(mm)800800800500800100010001000100Width(mm)9509501080125016001600200022002200Height(mm)9809801080125013201470168018802200Air outlet sectionLength(mm)400400400800500600600800800Width(mm)9509501080125016001600200022002200Height(mm)9809801080125013201470168018802200Note:Cooling condition: supply water/return water 7/12 oC, indoor dry bulb/wet bulb 27/19oC , fresh air dry bulb/wet bulb 35/28oC ;Heating condition: supply water/return water 60/50oC, indoor dry bulb/wet bulb 20/-oC,outdoor air dry bulb/wet bulb 7/6oC;Air volume, pressure, power in the table is standard parameters. It can be separately designed according to customer's requirements;Heater, humidifier, heat recovery device as optional parts, according to the customer requirements configured to the specific form;Unit standard USES G4 level filters, according to the customer requirements configured to the other forms;Unit length is decided for the number of function section. Specific details please consult us; Product DescriptionApplicationThe units are widely used in the air system of many inductries like mechanical ,electronic, textile,medical,chemical,energy and foo inductries ,etc. the units are also ideal solution for restaurants, office buildings,hospitals,theaters,supermarkets and palaestra.Air handling unit drawingGeneral comfortable occasion air handling unitConfiguration of basic function, early efficient filter and hot coil in air handling units (choose wet membrane humidification), it has the simple and highly controllable size characteristics of the function.Suitable for general building room comfort air conditioning process.Air handling units for all fresh air occasionConfiguration of basic function, primary filter or medium efficiency air filter, cooling coil ( enough margin, meet the needs of extreme conditions), it use steam, hot water heating, or natural gas direct combustion heating section( high thermal efficiency, low running cost); it also need to set the reheat, can choose the cooling reheat to control humidity and enhance the energy level, or set up the electric heater, to realize thermal compensation again after the summer dehumidification. It mainly meet the aerospace, automotive, instruments and meters, precision machining and other special industry requirements for air quality.Air handling units for general technology purification occasionThe configuration of the function section are: mixed section, cooling section, fan section, primary efficiency filter (G4) section, medium efficiency filter (F8) section. At the same time,it equipped with electric heating, electric humidification, muffler to satisfy high cleanliness, constant temperature and humidity,low noise control cleanliness project. Such as: inspection and quarantine laboratory, electronics factory workshop, biological engineering R&D center, food processing, precision machinery, pharmaceutical processing and storage area and other places which have strict requirements for temperature and humidity, cleanliness.Air handling units for general technology purification occasionIn addition to the general horizontal units, we can provide several kinds of structure forms of units, such as: vertical, ceiling, roof waterproof, etc.. They can meet the demand of different occasions. Ceiling structure unit can be installed on the ceiling. It is suitable for narrow room air conditioning or the area which has not a special equipment room;Roof waterproof structure unit can be installed on the outdoor roof or outdoor floor. Setting rofessional rainproof device and panel special thermal insulation design unit.Air handling units for operating room and high clean requirement occasionIn addition to the basic function of configuration, with primary efficiency filter or medium efficiency filter, it equipped with electric heating and humidification section. Considering particularity of medical situations, AHU adopt double cold source system ( chilled water + direct expansion) and efficient unhoused centrifugal fan, provide frequency conversion control, in order to satisfy the high reliability requirements.Air handling units with heat recovery deviceCan configured with wheel heat recovery device, hot and cold air passes through hot wheel, heat and moisture exchange is carried out by the difference of temperature and steam pressure between fresh air and exhaust air, effective recovery of sensible heat and latent heat in exhaust air, achieve the purpose of energy conservation.Honeycomb structure with aluminum foil carrier and high efficient moisture absorbing coating for heat storage core body of heat exchanger, excellent characteristics of heat storage, moisture absorption and heat transfer, efficiency is higher than 75%.Can configured with plate fin heat recovery device, so that the cold hot air flow directly through the same heat exchanger, in order to achieve the purpose of heat exchange.The heat exchanger adopts ginning aluminum foil, corrugated aluminum foil heat exchanger made of heat conductor, no interme-diate heat medium is required,no power consumption,no loss of temperature difference,temperature efficiency is higher than 75%.
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...