IPDB › China Industry › Instruments & Meters
China, Chinese Fully Automatic Infrared Oil Content in Water Analyzer1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Analysis InstrumentLiquid AnalyzerWater Oil Content AnalyzerInfrared Oil Content Analyzer
Xiangyi Thermal Instrument Limited
Preview:
Product Description Purpose and Reference Method EFully automatic infrared oil content in water analyzer is used for laboratory determination of oil content in industrial wastewater. Comply with national standards Water quality-Determination of petroleum, animal fats arvegetable oils-Infrared spectrophotometry Core technology displayComplete separation of waste gas treatment equipment reagents from water Core oil-water separator technology One film can be used 100 times One film can be accurately measured with a high precision syringe for a hundred times Free switching of magnesium silicate column Technical Characteristics of Fully automatic infrared oil content in water analyzerAutomated operation of sample processing, system cleaning, oil content determining andanalyzing. The extractant should be fullly isolated in alI processes such as storage, extraction, analyzing and waste discharge. The number of samples that can be processed continuously in a single batch≥10; Injection mode: automatic/manual injection mode, can be quickly switched; in automaticmodecan continuously measure the oil content in water from the connected pre-treatment unit;in manual mode, can be used for stand-alone operation to measure the oil content in waterthat extracted outside the pre-treatment unit;Tetrachloroethylene extraction method should ensure the extractionefficiency≥95%;Automatic measurement of water sample volume,error≤2%; Can prepare solutions of different concentration points on the curve, automaticallygenerate the standard curve; can identify unknown high concentration sample and automaticallydi lute according to the set concentration threshold; can set the di lution ratio. With insufficient alert function on extractant. Pre-treatment unit Using a 100OmL dedicated and graduated extraction bottle, with scale markings and forextraction use only; can be used for field sampling, no need to transfer water samples andcan be directIy tested on the machineThe extraction bottle shall be made of non-lipophilic material; a special sampling case shallbe equipped to meet the requirements of on-site sampling and sample transferring. Realtime accurate positioning of water sample cup; the reagent filling, sample extractionand waste discharge should all be equipped with independent pipelines,which do not interferewitheach other.Health and safety:Extraction and other operations do not require personnel involvement anddo not come into contact with reagents. Standard fume hood operations ensure personnel's health.High precision automatic injector: Reagent 0~600ml can be set arbitrarily, with automaticdilution at high concentrations, automatic quality control sample preparation,and automaticone click calibration for curve making;One click calibration: Standard infrared oil standard filters can be used for one click calibration, with multiple calibrations without the need for reagents. At the same time,single point and multi-point automatic detection and calibration are convenient and fast;One click completion: Turn on the machine and complete multiple water sample tests with oneclick, without any other operations in between, reducing the workload of operators;One click completion: Turn on the machine and complete multiple water sample tests withone click, without any other operations in between, reducing the workload of operators; Coreoil water separation technology: The effective filtration area of the anti blocking anddemulsification membrane is more than 45mm, and the double membrane separation replacesanhydrous sodium sulfate. One membrane can be used 100 times, and there is an audible andvisual alarm when the membrane is broken;Built-in 12 inch touch computer, Windows full system control, USB interface with intelligent information processing, storage, printing, small size can be placed in a conventional standard1.2 meterfume hood;The dual system of the ultraviolet infrared oil measuring instrument switches the oilmeasuring instrument software with one button, and has a software copyright certificate.It can switch between semi-automatic and fully automatic operations with one button;Unlimited automatic filling, replacement, and emission of magnesium silicate meet thenational standard. One replacement can automatically detect total oil, petroleum, or animaland vegetable oils, and automatically display the remaining amount of magnesium silicate;Three wave number characteristic peak spectrogram scanning, automatic scaling of thespectrogram, and the accuracy of sample concentration can be traced through absorption peakscanning spectrogram as evidence;Fault self inspection: automatic detection of pre processing and host failure upon startupsound andlight alarm forfaults;Automatic separation and collection of wastewater and waste tetrachloroethylene, automaticdetection and display of reagent residue, and upgraded automatic recovery and reuse of waste1iquid;The mobile app can remotely operate and monitor, allowing for the appointment of new watersamples without stopping the ongoing process without any impact, and the infinite cycle ofsample preparation does not stop;The data produced by the instrument can be directly accessed and uploaded to the laboratorydata platform through the RS486 communication protocol;Good baseline stability: automatic real-time adjustment of zero point (eliminating theimpact of baseline drift); User site
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...