IPDB › China Industry › Instruments & Meters
China, Chinese TS3000 Magnetic Properties Multi-function Measuring System for Electrical Steel1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Test InstrumentOther Test InstrumentElectrical Steel Magnetic Measuringmagnetic core tester
Tunkia Co., Ltd.
Preview:
Product Description TS3000 Magnetic Properties Multifunction Measuring System for Electrical Steel*Above picture is only for reference, subject to actual delivery1. SummaryTS3000 is a special instrument for measuring the AC/DC magnetic properties of electrical steel under different temperature conditions. It consists of excitation and measurement host (AC and DC), several high temperature Epstein frames, single sheet tester (optional), Permeameter program-controlled switching device, temperature controller, automatic measuring software, etc. 2. FeaturesElectrical parameters calibration function.Measurement of magnetic field by M.C and H-Coil (optional).Maximum magnetization field reaches 30 kA/m (700 T Epstein frame).The maximum frequency can be selected to 20kHz.2 ~ 63 harmonics influence measurement (optional).Slowly reduce amplitude demagnetization for specimen.Temperature impact test can be conducted.Software controlled automatic measurement.Automatic multi-point measurement.The software has been configured with multiple measurement schemesAutomatic calculates magnetic parameters and curves.Modular design, easy to upgrade or maintenance.Ultra-wide range of current continuously and stably regulated.Switch the Permeameter by software without repeated wiring. 3. The Reference StandardIEC 60404-2 "Magnetic materials-Part 2 Methods of measurement of the magnetic properties of electrical steel strip and sheet by EP".IEC 60404-3 "Magnetic materials-Part 3 Methods of measurement of the magnetic properties of electrical steel strip and sheet by SST".IEC 60404-10 "Magnetic materials-Part 10-Methods of measurement of magnetic properties of electrical steel strip and sheet at medium frequencies". 4. Applications5. Specifications of magnetic parametersFrequencyParameterRange[1]Uncertainty (k=2) [6]Repeatability[6]DCHm1 A/m...30 kA/m0.5%0.2%Jm10 mT...2.0 T1.0%0.3%Bm10 mT...2.1 T1.0%0.3%Br--1.0%0.3%Hc--1.0%0.5%μi--4.0%1.5%μm--2.0%1.0%<50HzHm5 A/m...10 kA/m / 30 kA/m[5]0.5%0.2%Jm / BmB5[2]... B10000 / B30000[5]0.5%0.2%PsP0.1[3]... P1.9 ( P1.7 )1.0%0.3%50Hz / 60HzHm5 A/m...10 kA/m / 30 kA/m[5]0.3%0.2%Jm / BmB5[2]... B10000 / B30000[5]0.3%0.1%PsP0.1[3]... P1.9 ( P1.7 )0.5%0.2%400 HzHm5 A/m...2.5 kA/m0.5%0.2%Jm / BmB5[2]... B25000.5%0.2%PsP0.1[3]... P1.7 ( P1.5 )1.0%0.5%1 kHzHm5 A/m...800 A/m1.0%0.3%Jm / BmB5[2]... B8001.0%0.3%PsP0.1[3]... P1.5 ( P1.0 )2.0%0.5%2.5 kHzHm5 A/m...200 A/m1.0%0.3%Jm / BmB5[2]... B2001.0%0.3%PsP0.1[3]... P1.02.0%0.5%10 kHzHm5 A/m...100 A/m2.0%0.5%Jm / BmB5[2]... B100 2.0%0.5%PsP0.1[3]... P0.54.0%1.0%20 kHzHm5 A/m...50 A/m2.0%0.5%Jm / BmB5[2]... B502.0%0.5%PsP0.1[3]... P0.24.0%1.0%Conditions :(23 ± 5)oC, demagnetized before measurement.Accuracy: 1%~2% deviation will occur according to the way and position of loading the sample in the measuring frame.Repeatability: put the same specimens in the specified position and keep it from moving, and measure it repeatedly for 10 times. Take the maximum or minimum value of 10 measurements minus the average value divided by the average value, and the maximum value of the two represents repeatability.Note: [1] The table only gives reference measuring points, and the indexes such as Hm, Jm/Bm, Ps that can be reached by the specimens during actual measure are related to the performance of the material, quality of the specimens, frequency, current, voltage, etc.Note: [2] B5 refers to the magnetic flux density value when the magnetic field H is 5 A/m, and the typical measuring points of non-oriented steel are in parentheses.Note: [3] P0.1 refers to the specific total loss value when flux B is 0.1T, and the typical measure point for non-oriented steel is in parentheses.Note: [4] For medium and high frequency measurment, select the corresponding Epstein frame.Note: [5] When the selected effective excitation power is 1500VA, the magnetic field can reach 30 kA/m with the corresponding Epstein frame.Note: [6] The uncertainty and repeatability are at typical measuring points, and are related to the performance of the measured material.6. Specifications of Electrical Parameters (AC)Output capabilityVoltage0.1 Vrms~200 VrmsFrequency3 Hz... 2.5 kHz...10 kHz...20 kHz (optional)Power0 ~ 500VA / 1500 VA Optional (see selection guide)Current500VA500 VA / 1500 VA (optional)1500VA0.5 mApk ~ 15 Apk Harmonic2... 63 (optional)SpecificationFrequency (Hz)Uncertainty of Effective value of voltage and current(k=2)Uncertainty of active power(k=2)3 ≤ F < 450.1%*RG [7]0.2%*FS [8]45 ≤ F ≤ 650.05%*RG [7]0.1%*FS [8]65 ≤ F ≤ 4000.05%*RG [7]0.15%*FS [8]400 < F ≤ 1 k0.1%*RG [7]0.2%*FS [8]1 k < F ≤ 2.5 k0.2%*RG [7]0.5%*FS [8]2.5 k < F ≤ 10 k0.5%*RG [7]1.0%*FS [8]10 k < F ≤ 20 k1.0%*RG [7]2.0%*FS [8]Note: [7] RG is range;Note: [8] FS= Voltage range x current range, when the phase Angle is within 75 degrees. 7. Specifications of Electrical Parameters(DC)Output capacityVoltage± 0.1 V ~ ± 20 VCurrent± 0.5 mA ~ ± 40 APower0 ~ 800 WAdjustment Fineness of Current0.005%*RGSpecificationCurrentUncertainty(k=2)0.2%*RGFluxRange5 mWb,100 mWb,350 mWbZero-drift± (0.05%*RG) / min or± 1 μWb/min (Whichever is greater)Uncertainty(k=2)0.3%*RG+ 5 μWb 8. Temperature ControllerInside Volume150 LInside Dimensions500mm × 600 mm × 600 mm(W × D × H)QualityAbout 250kgTemperature Range-40oC~200oCLow temperature to-50oC,High temperature to 220oCStability of Temperature± 0.5oCDeviation of Temperature ± 2.0oCTime of Temperature RiseTemperature rises from -40 ° C at 1~5 ° C every minute. The total time to 200 ° C is less than 70 minutes.Time of Temperature DropThe compressor starts at 25 ° C and the temperature drops at 1~ 4 ° C every minute. When the temperature drops to -40 ° C, the cooling time is less than 35 minutes 9. Epstein FrameThe built-in coil of air flux compensation conforms to IEC60404-2 or IEC60404-10 standards.The cutting and placement of specimens shall comply with IEC60404-2.TypeModelLengthTurnsLumenHeightMeasurement MethodMaximum Magnetization FieldWorkingTemperatureFrequencyRegular Epstein FrameTS7000-A25 cm700 T10 mmM.C10 kA/m0oC~45oC≤400 HzTS7000-B25 cm700 T10 mmM.C30 kA/m0oC~45oC≤400 HzTS7000-A-HM25 cm700 T10 mmM.C / H-Coil10 kA/m0oC~45oC≤400 HzTS7000-B-HM25 cm700 T10 mmM.C / H-Coil30 kA/m0oC~45oC≤400 HzMedium Frequency Epstein FrameTS701025 cm200 T5 mmM.C800 A/m0oC~45oC400 Hz~10 kHzHigh Frequency Epstein FrameTS702025 cm100 T5 mmM.C100 A/m0oC~45oC10 kHz~20 kHzHigh Temperature Epstein Frame TS7100-A25 cm700 T10 mmM.C10 kA/m-55oC~220oC≤400 HzTS7100-B25 cm700 T10 mmM.C30 kA/m-55oC~220oC≤400 HzTS7100-B-HM25 cm700 T10 mmM.C / H-Coil30 kA/m-55oC~220oC≤400 Hz Note: The user shall select the corresponding Epstein frame according to the test frequency and the maximum magnetic field.Note: Select both M.C and H-coil for measurement. The host must support the M.C and H-coil methods. 10. Single Sheet Tester (optional)TypeModelSpecimens size (W × L)Specimens ThicknessMeasurement MethodMaximum Magnetization FieldWorkingTemperatureFrequencyBasic editionTS7500500 mm × 500 mm0.1 mm~0.5 mmM.C10 kA/m0oC~45oC≤100 HzUpgrade editionTS7510-A500 mm × 500 mm0.1 mm~0.5 mmM.C10 kA/m0oC~45oC≤100 HzTS7510-B300 mm × 300 mm0.1 mm~0.5 mmM.C10 kA/m0oC~45oC≤100 HzTS7510-C100 mm × 300 mm0.1 mm~0.5 mmM.C10 kA/m0oC~45oC≤100 HzTS7510-D30 mm × 300 mm0.1 mm~0.5 mmM.C10 kA/m0oC~45oC≤100 HzTS7510-A-HM500 mm × 500 mm0.1 mm~0.5 mmM.C / H-Coil10 kA/m0oC~45oC≤100 HzTS7510-B-HM300 mm × 300 mm0.1 mm~0.5 mmM.C / H-Coil10 kA/m0oC~45oC≤100 HzTS7510-C-HM100 mm × 300 mm0.1 mm~0.5 mmM.C / H-Coil10 kA/m0oC~45oC≤100 Hz TS7510-D-HM30 mm × 300 mm0.1 mm~0.5 mmM.C / H-Coil10 kA/m0oC~45oC≤100 HzNote: If single sheet tester supporting H-coil is selected. The host shall support the M.C and H-coil.11. Solenoid (optional)ModelTS7750-A-55-600 TS7750-B-55-600TypeSingle solenoid Double solenoidDiameter (Ф)55 mm55 mmLength (L)600 mm600 mmTurnsAbout 2270 TAbout 2270 TMaximum current (Imax)DC,± 20 ADC,± 10 ACoil constant (KH)About 3780 1/mAbout 3780 1/mCoil constant (KB)About 4.75 mT/AAbout 4.75 mT/ACoil impedanceAbout 1.8 ΩAbout 3.6 ΩDimensions (L×W×H,mm)650 × 230 × 230650 × 600 × 230QualityAbout 50 kgAbout 100 kgWorking temperature0°C~45°C0°C~45°CNotes:The maximum magnetic field that can be achieved is related to the power load capacity. 12. Multichannel Permeameters SwitchThe device is an accessory for a device measuring the magnetic properties of soft magnetic materials or electrical steel.A number of magnetic measuring host (DC or AC) or excitation device (Epstein frames, single sheet testers, etc.) terminal of the excitation and the measuring terminal can be connected to the device by wire, and freely switch through software.Access up to 2-channel magnetic measuring host and 6-channel excitation device. Company Profile
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...