IPDB › China Industry › Industrial Equipment & Components
China, Chinese Factory Price Original Siemens Sqn70.224b20 Damper Actuator Servo Motor for Industrial Burner1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Boiler FurnaceBoiler PartsBoiler PartsServo Motor
Shenzhen YHG Heating Science & Technology Co., ltd
Preview:
Product Description Factory Price Original Siemens SQN70.224B20 Damper Actuator Servo Motor For Industrial BurnerOVERVIEW Spacious connection chamber for ease of installation Actuators can be delivered ready installed on butterfly valves BVG, BVGF, BVA, BVAF, BVH, BVHS or linear flow control VFCActuator IC 40 is designed for all applications that require precise, controlled rotary movement between 0° and 90°. It can be mounted directly onto the butterfy valves BVG, BVGF, BVA, BVAF, BVH, BVHS or linear fow control VFC in order to control the gas and air fow rates on gas burners. Actuators and butterfy valves or linear fow control VFC can also be delivered ready assembled as butterfy valves with actuatorIBG,IBGF,IBA,IBAF,IBH,IBHS orlinear fow control IFC.PRODUCT PARAMETERSNameServo motorBrandSiemens ModelSQN70.224B20OriginGermanyDeliver Time3~15 daysUsagegas burner accessories TheIC 40 can be used on continuously-controlled burners and on stage-controlled burners.Settings on the actuator IC 40 can be made using a PC with the programming software BCSoft. All the relevant settings for the process are made using the software via an optical interface. Various operating modes, which may be modifed, are stored in the unit. In addition, the control type (two-point signal, three-point step signal or continuous control), running times, adjustment angles and intermediate positions can be programmed.The actuator can also be controlled "by hand" using the soft-ware.Once set, all the parameters can be saved on the PC and copied from there into other actuators, thus saving time dur-ing the commissioning process.Service technicians can call up statistical data using BCSoft, such as hours of operation, actuating cycles and a fault history. Some values can also be set to zero, for example to record data over a specifc period of time.Examples of applicationFor processes that require a homogeneous temperature dis-tribution in the furnace. The actuator IC 40 is controlled by a two-point controller and operates in On/Off or High/Low intermittent mode.The actuator closes when the voltage sup-ply is interrupted. The running time can be adjusted between 5 and 25 seconds.FunctionThe actuator IC 40 moves the butterfy valve towards 0° or 90°. There are 4 possible positions which the actuator can approach in steps. Any intermediate position is possible in continuous three-point step mode. Optionally, the actuator can also approach anyintermediate position via an additional current input.The slow fashing blue LED indicates that the motor of actuator IC 40is moving. The positionindicator on the housingindicates the opening angle. Further visualization and operation are performed on a PC using the BCSoft software.RECOMMEND PRODUCTS WARNING1,Do not install it in the following places(1)Places where special drugs or corrosive gases are present (e.g. ammonia, sulfur, hydrochloric acid, ethylene compounds, etc.)(2)Places where water drops or is too wet.(3) High temperature places.(4) A place where the vibration lasts for a long time.2, Please connect according to the specified basis.3, In order to prevent electric shock and meter damage, please connect the power supply last. Misunderstanding that touching other subterminals can cause accidents and damage to the meter.4,The load of each terminal connection should not exceed the rated value.5,Please use the power supply with the same voltage and frequency as indicated by the machine.6,For timers and auxiliary relays used as additional functions, please select reliable products and correctly form loops according to your needs.7,Please ground according to the standard above D type grounding specified in the electrical equipment technical standard, and be sure to ground the burner body.8,Do not tie the power cord and the high-voltage cable of the ignition transformer with the wire of the flame monitoring rod, and do not put it in the same wire tube, please wire separately.In particular, the high-voltage cable should be distributed separately, 10 cm away from the burner controller Above.9,Please connect the ignition transformer high-voltage cable reliably to ensure that there is no bad contact. Poor contact will produce high frequency waves, radio noise, etc., causing misoperation. In addition, install the ignition transformer directly with the burner body or the metal part electrically connected to the burner body.10,After connecting cables, ensure that the cables are correctly connected. Incorrect wiring may damage the unit or cause incorrect actions.ABOUT UShttps://yhg688.en.made-in-china.com/company-Shenzhen-YHG-Heating-Science-Technology-Co-ltd.html
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...