IPDB › China Industry › Instruments & Meters
China, Chinese Acrel Three Phase Energy Meter Last 128 PCS of Alarm Records Apm520-D36/CE1 Industrial Products Supplier Manufacturer Details, price list catalog:
China Industrial Products Supplier Manufacturer List Catalog
Meter for ElectricityOther Meters for ElectricityMulti-Function Power MeterThree Phase Energy Meter
ACREL CO., LTD.
Preview:
Product Description Product DescriptionAPM5 series network power meter (hereinafter referred to as the meter) is designed according to IEC international standards, with full power measurement, power statistics, power quality analysis (including harmonics, flicker), fault recording function (including voltage temporary rise and fall interrupt, inrush current and other records), event recording function and network communication and other functions. It is mainly used for comprehensive monitoring of power supply quality in the power grid. This series of meters is equipped with feature-rich DI/DO modules, AO modules, wireless communication modules, leakage temperature measurement modules, which can flexibly realize the full electrical circuit Power measurement and switching status monitoring. Product model specifications and functions.Product ParametersMeasuredparametersTotal electrical measurementFour-quadrant energy,Split phase electricity,Apparent energy,Multi-rate energyPulse output of energyTotal active ,Total reactive energy pulse output (72 type only has active energy pulses) DemandThree-phase current, active power, reactive power, real-time demand of apparent power, and maximum demand (including time stamp)Extremevalue statisticsCurrent, line voltage, phase voltage, active power, reactive power and other electrical parameters extreme values of this monthand last month (including time stamps)Power qualityUnbalance of current, line voltage, phase voltageVoltage phase angle, current phase angleTotal (odd, even) harmonic content of voltage and currentHarmonic content of voltage and current (2-63 times)Interharmonic (included with option S).Flicker (included with S option).Voltage peak coefficientTelephone waveform factorCurrent K-factorVectorVoltage and current waveformFundamental voltage and currentFault waveform recordingRecord of voltage ramp-up and drop interruptions, inrush currents, etc. (included with S option).Event loggingDIDO records, which can record the last 128 DID recordsAlarm loggingThe last 128 alarm records can be recordedCommunicationModbus - RTU protocol, DL/T 645-2007 statuteSwitching value72 Shape: 2 channels of switching input + 2 channels of switching output;96 Shape: 4 switching inputs + 2 switching outputsBase modelBasic functionOptional functionOption GroupAPM5102DI2DO1EP1C1. CE (Ethernet Communication/MODBUS-TCP).1+5+6+7+82+3+4+7+85+6+7+8+95+6+7+8+105+6+7+8+115+6+7+8+122.2C (Extended 2nd Communication).3.K (2 switch inputs + 2 switch outputs).4.2M (2ch analog).5.T (4-channel NTC temperature measurement).6.L (1 channel leakage).7.F (Compound Rate).8.S (0.2S level + fault recording).9.WF(WiFi Communication)10.LR(Lora Communication)11.4G(4G Communication)Base modelBasic functionOptional functionOption GroupAPM5204DI2DO2EP1C1. CE (Ethernet Communication/MODBUS-TCP).1+5+6+7+82+3+4+7+81+5+6+7+82+3+4+7+85+6+7+8+95+6+7+8+105+6+7+8+115+6+7+8+12DisplayDisplay methodDot matrix liquid crystal; Switch between Chinese and English Resolution128*128; BacklightWhite LED; Visible area72 Shape: 38mm*46mm (1.78"/2.3");96 Shape: 56mm*60mm (2.46"/3.2"); SignalElectrical networkThree-phase three-wire, three-phase four-wire, see the wiring diagram; Frequency45~65Hz; VoltageRating: AC 3*57.7/100V, AC 3*63.5/110V, AC 3*230/400V, AC 3*400/690V (96 Shape only); Overload: 1.2 times the rating (continuous); 2x rating/1 second; Power consumption: < 0.5VA(Every way); CurrentRatings: AC 3x 1 (1.2) A, AC 3x5(6)A; Overload: 1.2 times the rating (continuous); 10x rating/1 second; Power consumption: < 0.5VA(Every way); Measurement accuracyVoltage, currentIEC 61557-12 0.2% Measurement accuracyVoltage, currentIEC 61557-12 0.2% Voltage harmonics, current harmonicsIEC 61557-12 1% FrequencyIEC 61557-12 ±0.02Hz Active powerIEC 61557-12 0.5% Reactive powerIEC 61557-12 1% Active electrical energyIEC 62053-22 0.5S class (0.2S accuracy when S is selected). Reactive powerIEC 62053-24 Class 1Power quality (only available when S is selected).Waves recording20 waveforms, 10 waves before and after; Waveform capture128 cycle points are stored per waveform;Switch inputDry contact input, built-in power supply;Response time: less than 300msRelay outputContact type: normally open contact;Contact capacity: AC 250V/3A DC 30V/3A;Energy pulse outputOutput mode: photocoupler pulse with open collector;Pulse constant: 10000imp/kWh (default);communicationRS485 interface/Modbus-RTU protocol and DLT645 protocol;RJ45 interface (Ethernet)/Modbus-TCP protocol;Wireless interfacepower supplyWorking range: AC 85V~265V; DC100V~350VPower consumption: power consumption≤15VA;SafetyPower frequency withstand voltageThe power frequency withstand voltage between the housing and the auxiliary power supply, each input and output terminal group isAC 4kV/1min;The power frequency withstand voltage between the auxiliary power supply and each input terminal and each output terminal group isAC 2kV/1min;The power frequency withstand voltage between the voltage input and other input and output terminal blocks is AC 2kV/1min;The power frequency withstand voltage between the current input and other input and output terminal blocks is AC 2kV/1min;The power frequency withstand voltage between the relay output and other input and output terminal blocks is AC 2kV/1min;The power frequency withstand voltage between the terminal groups of switching input, communication, analog output and pulseoutput is AC 1kV/1min; Insulation resistanceInputs,outputs to the shell>100MΩ;Electromagnetic compatibilityComplies with IEC 61000 standard (Level 4);EnvironmentOperating temperature:-25oC~+70oC;Storage temperature:-40oC~+85oC;Relative humidity:≤95% without condensation;Altitude:≤2500m;Protection LevelDisplay panel IP54; (Optionally IP65).StandardsIEC 60068-2-1IEC 60068-2-2IEC 60068-2-30Environmental Testing-Part 2-1:Tests Test A:Cold IDAEnvironmental Testing Part 2-2:Tests Test B:Dry heatEnvironmental Testing Part 2-30:Tests Test Db:Damp heat,cyclic (12+12h)IEC 61000-4Electromagnetic compatibility-Testing and measurement techniquesIEC 61557-12Electrical safety in low voltage distribution systems up to 1 000V a.c. and 1 500V d.c -Equipment for testing, measuring ormonitoring of protective measures - Part12:Performances measuring and monitoring devices(PMD)IEC 62053-22Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2S and 0.5S)IEC 62053-24Electricity metering equipment (a.c.)-Particular requirements - Part24:Static meter for reactive energy at fundamental frequency(classes 0.5S 1S and 1)
Purchasing Request
Note: Send your purchase request, and we will screen suppliers or manufacturers for you free of charge...